*T3 INTERFACE TRANSFORMER
Turns Ratio ( + 2% ) 1:2CT
PARAMETER Inductance
MIN. 19
MAX.
UNITS µHy
Rise Time
3.00
nS µHy
Flammability: Materials used in the production of these units meet requirements of UL94-VO and IEC 695-2-2 needle flame test. Parts shipped in anti-static tubes. 44 pieces per tube
Leakage Inductance
0.06
Capacitance (CW/W) Primary DC Resistance
1
10
pF
0.3 3000
ohms VRMS
Isolation
Tape & Reel Available
3 dB Bandwidth is .200 - 340 (MHz) typical, tested in a 75 ohm system
1
Reinforced insulation * Also suitable for DS3, E3 and STS-1 interfaces
5
6 4 2
PHYSICAL DIMENSIONS All dimensions in inches (mm):
3 1
.410 (10.41) MAX.
.410 (10.41) MAX.
.260 (6.60) MAX.
.300 (7.62) MAX.
SCHEMATIC DIAGRAM
.020 (0.51) TYP.
.100 (2.54) TYP.
.010 (0.25) TYP.
.040 (1.02) TYP. .510 (12.95) .480 (12.19)
RHOMBUS INDUSTRIES INC. FSCM NO. 16714
RHOMBUS P/N: T-13109G CUST P/N: NAME: DATE: 7/25/97 SHEET: 1 OF 1
Rhombus Industries Inc.
Transformers & Magnetic Products
15801 Chemical Lane, Huntington Beach, CA 92649 Phone: (714) 898-0960 FAX: (714) 896-0971
www.rhombus-ind.com