T1/CEPT/ISDN PRI INTERFACE TRANSFORMER
Reinforced Insulation Per EN 41003/EN 60950
Turns Ratio ( + 5% )
Parameter Min.
1CT:2CT
Max. Units
Open Circuit Inductance
Oscillation Voltage = 20mV Oscillation Frequency = 100.0 KHz
1.2
mH
Leakage Inductance
Oscillation Level = 20mV Oscillation Frequency = 100.0 KHz
0.55
µH
Flammability: Materials used in the production of these units meet requirements of UL94-VO and IEC 695-2-2 needle flame test.
Interwinding Capacitance (CW/W) Primary DC Resistance Secondary DC Resistance Isolation (HI-POT)
30
pF
Oscillation Frequency = 100.0 KHz
Parts shipped in anti-static tubes. 31 pieces per tube
0.7 1.1 3000
ohms ohms V MS R
Surface mount version of this part available. Part# T-13614G
Physical Dimensions inches (mm)
Schematic Diagram
RHOMBUS P/N: T-13614 CUST P/N: DATE: 04/25/96 NAME: SHEET: 1 OF 1
R hombus Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649-1595 Phone: (714) 898-0960 FAX: (714) 896-0971