Turns Ratio ( + 1% )
PARAMETER Inductance (6-4)
1
(6-4):(1-3)= 2.42 : 1
MIN. 2.3 MAX. UNITS mH µH
T-13813G
PULSE TRANSFORMER
Leakage InductancePins 6-4 with 1-3 shorted 2 Capacitance (CW/W) (Pri/Sec) Primary DC Resistance (1-3)
1
2.0
25
pF
0.193
0.236
ohms
SCHEMATIC DIAGRAM:
6
Secondary DC Resistance (6-4) 0.495 0.605 ohms
1
Sec (Divice)
Pri (Line)
Dielectric Withstand 1500 VRMS
5 4
1. 10 KHz and 1 VAC. 2. 10 KHz and 100 mAAC.
3
Physical Dimensions in inches (mm)
.370 (9.40) MAX.
.375 (9.53) MAX.
6
.525 (13.34)
1
.375 (9.53) MAX. .025 (0.64) .34 (8.6) .098 (2.50) .028 (0.70) .505 (12.83) .490 (12.45)
5 4
Suggested Pad Layout
.100 (2.54) TYP. .050 (1.27) TYP.
2 3
.075 (1.905) TYP.
4/16/99
Rhombus Industries Inc.
Transformers & Magnetic Products
15801 Chemical Lane, Huntington Beach, CA 92649 Phone: (714) 898-0960 FAX: (714) 896-0971
www.rhombus-ind.com