Digital Audio Transformer
Turns Ratio ( + 2% ) 1:1
T-1396
MAX. UNITS µHy 0.7 2 µHy
PARAMETER
1
MIN. 225
NOM.
Open Circuit Inductance Leakage Inductance Interwinding Capacitance (CW/W)
2
SCHEMATIC DIAGRAM
1
2,3
6
pF ohms VRMS
DC Resistance (any winding) Isolation (HI-POT) TEST CONDITIONS: 1500
0.1
1. Oscillation Voltage = 100mV & Oscillation Frequency = 10.0 KHz 2. Oscillation Voltage = 100mV & Oscillation Frequency = 100.0 KHz 3. With Shield to Ground
3 2
PINS 2 & 5 SHIELD
4 5
Flammability: Materials used in the production of these units are UL94-VO and meet requirements of IEC 695-2-2 needle flame test.
Parts shipped in anti-static tubes. 50 pieces per tube
3 2 1
4 5 6
PHYSICAL DIMENSIONS inches (mm)
.500
(12.70)
MAX.
.350 (8.89) MAX.
.250
(6.35 )
MAX. .080 (2.03) .340 (8.64) .120 (3.05) MIN.
.400
(10.16)
.100 (2.54) TYP.
.020 DIA. (0.51) TYP.
RHOMBUS P/N: T-1396 CUST P/N: DATE: 05/09/97 NAME: SHEET: 1 OF 1
Rhombus Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649-1595 Phone: (714) 898-0960 FAX: (714) 896-0971