Line Transformer
Turns Ratio Parameter Inductance 1-5 (2-4, Shorted) Leakage Inductance DC Resistance (1-4) DC Resistance (2-5) DC Resistance (9-7) Hi-Pot Primary to Secondary Total Harmonic Distortion @40 kHz, 12 Vp-p ( Pri:Sec.) Insertion Loss @100kHz Frequency Response @40kHz-300kHz, 100kHz Ref. Longitudinal Balance @ @40kHz-300kHz. 50 2050 -80 0.75 + 0.25
2 1
4 : 1 + 1% Min. 1.88 Typ. 2.00 Max. 2.12 11 1.26 1.25 1.00 Units mH µH Ω Ω Ω VRMS dB dB dB dB Schematic Diagram
1 4 Pri. 2 5
(Line Side)
9 Sec. 7
(Chip Side)
1..Tested at 10 kHz and 100 mV 2..Pins 1-5, 2-4 shorted, and 9-7 Shorted. Tested at 100kHz - 100 mV.
Designed to meet UL1950 (Double Insulation)
Materials used in construction of this component meet or exceed UL Class B and can be operated up to 130oC Dimensions in Inches (mm)
.522 (13.26) MAX.
.532 (13.51) MAX.
.715 (18.15)
1 2 10 9 8 7 6
.100 (2.54) TYP.
.516 (13.1) MAX.
3 4 5
Suggested Pad Layout
.050 (1.27) TYP.
.100 (2.54)
.028 (0.70)
.025 (0.64)
.516 (13.1)
.100 (2.54) TYP.
.675 (17.15) .663 (16.85)
RHOMBUS P/N: T-1416 CUST P/N: DATE: 10/27/99 NAME: SHEET:
R hombus Industries Inc.
Transformers & Magnetic Products
15801 Chemical Lane, Huntington Beach, CA 92649 Phone: (714) 898-0960 www.rhombus-ind.com FAX: (714) 896-0971
很抱歉,暂时无法提供与“T-1416”相匹配的价格&库存,您可以联系我们找货