Electrical Specifications at 25o C PARAMETER Insertion Loss (0.1 to 125 MHz) Rise Time (10 to 90%) Return Loss: (0.1 to 60 MHz) TX (0.1 to 60 MHz) RX (60 to 100 MHz) TX (60 to 100 MHz) RX Differential to Common Mode Rejection (0.1 to 60 MHz) TX (0.1 to 60 MHz) RX (60 to 100 MHz) TX (60 to 100 MHz) RX Crosstalk (0.1 to 60 MHz) (60 to 100 MHz) Min. TYP. -1.1 2.5 UNITS dB ns
SMD versions available on Tape & Reel
Designed for 155Mbps ATM applications over UTP-5 cable Supports 100 Base-X and Twisted Pair FDDI Supports either transmit or receive channels IEEE 802.3 Compatible Low common mode emisions Fast Rise Times
SCHEMATICS RX+
-15 -17 -11 -15
dB dB dB dB
RD-45 -40 -40 -35 -40 -38 1500 dB dB dB dB dB dB
16 13
9 11
14
RD+ 15
10
RX-
TD- 1
Isolation Vrms
3 4 2
8
TX-
TX = TRANSMIT CHANNEL RX = RECEIVE CHANNEL
TD+
7
TX+
Dimensions in Inches (mm)
1.0 (25.40) MAX. .410 (10.41) MAX.
.260 (6.60) .300 MAX. (7.62) MAX.
.010 (0.25) TYP. .040 (1.02) TYP. .510 (12.95) .480 (12.19)
.020 (0.51) TYP.
.100 (2.54) TYP.
Available on Tape & Reel
Rhombus P/N: Cust. P/N: Date: 5/22/98
T-15503 Name: Sheet: 1 of 1
Rhombus Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649-1595 Phone: (714) 898-0960 z FAX: (714) 896-0971