Thermoelectric Module Datasheet
Performance Parameters
Type ΔTmax Qmax K W
69 71 72 72 72 72 3.7 2.4 1.6 1.2 1.1 0.9
RMT Ltd
1MD04-024-XX
Imax A
2.3 1.5 1.0 0.8 0.7 0.5
Umax AC R H V Ohm mm
0.90 1.50 2.9 2.41 3.16 3.61 4.52 0.9 1.1 1.4 1.6 1.8 2.1
H2* mm
1.4 1.6 1.9 2.1 2.3 2.6
h mm
0.9 0.5 0.8 1.0 1.2 1.5
1MD04-024-xx (N=24)
1MD04-024-03 1MD04-024-05 1MD04-024-08 1MD04-024-10 1MD04-024-12 1MD04-024-15
Performance data are given at 300K, vacuum
*Optional H2 value is specified for 0.5mm ceramics thickness
Technical Drawing
Options available
A. TEC Assembly: Solder SnSb (Tmelt=230°C) C. Ceramics Surface Options D. Thermistor (optional) 1. Blank ceramics Can be mounted to cold side 2. Metallized: ceramics edge. Calibration 2.1 Ni / Sn(Bi) B. Ceramics: is available. 2.2 Gold plating 1.Pure Al2O3(100%) 3. Metallized and pre-tinned: 2.Alumina (Al2O3- 96%) E. Terminal wires 3.1 Solder 94 (PbSnBi, Tmelt=94°C) 3.Aluminum Nitride (AlN) 1. Pre-tinned Copper 3.2 Solder 117 (In-Sn, Tmelt=117°C) 2. Insulated Wires 3.3 Solder 138 (Sn-Bi, Tmelt=138°C) 100% Al2O3 used as standard 3. Insulated Color Coded 3.4 Solder 183 (Pb-Sn, Tmelt=183°C) 4. Wire Bonding Pads
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 1 of 5
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1MD04-024-03
Temperature difference, K
Current, A
Temperature difference, K
Heat Pumped at the Cold Side, W
Voltage, V
Temperature difference, K
C.O.P
Temperature difference, K
Performance Plots
1MD04-024-05
Temperature difference, K
Current, A
Temperature difference, K
Heat Pumped at the Cold Side, W
Voltage, V
Temperature difference, K
C.O.P
Temperature difference, K
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 2 of 5
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1MD04-024-08
Temperature difference, K
Current, A
Temperature difference, K
Heat Pumped at the Cold Side, W
Voltage, V
Temperature difference, K
C.O.P
Temperature difference, K
Performance Plots
1MD04-024-10
Temperature difference, K
Current, A
Temperature difference, K
Heat Pumped at the Cold Side, W
Voltage, V
Temperature difference, K
C.O.P
Temperature difference, K
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 3 of 5
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1MD04-024-12
Temperature difference, K
Current, A
Temperature difference, K
Heat Pumped at the Cold Side, W
Voltage, V
Temperature difference, K
C.O.P
Temperature difference, K
Performance Plots
1MD04-024-15
Temperature difference, K
Current, A
Temperature difference, K
Heat Pumped at the Cold Side, W
Voltage, V
Temperature difference, K
C.O.P
Temperature difference, K
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 4 of 5
Thermoelectric Module Datasheet
Additional Options TEC Polarity
TEC Polarity can be changed for free by request. The specified in this datasheet polarity is typical. It can be reversed without charge in accordance to Customer application requirements.
RMT Ltd
-
+
+
-
WB Posts or Pads
WB pads or WB posts solutions are available. WB pads (no posts) are provided as standard. WB Posts solution is provided in accordance to Customer’s demands and depending of TEC height. WB Pads WB Posts
Customized Au Patterns
Customized Au patterns solution on TEC cold side ceramics is available. Selective Pre-tinning solution is available. Please, contact us for additional information about customized Au patterns requirements. Au Pattern Pre-tinning
Application Tips
1. Never heat TE module more than 200˚C (TEC assembled at 230˚C). 2. Never use TE module without attached heat sink at hot (bottom) side. 3. Connect TE module to DC power supply according to polarity. 4. Do not apply DC current higher than Imax.
Installation
1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types require other assembling methods in most cases. 2. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option and also makes pre-tinning for TE modules. 3. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good thermoconductive properties. A glue is usually based on some epoxy compound filled with some thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a specific type depends on application features and the type of a TE module.
Object being cooled
Object being cooled
TEC 1 Screw mounting Heatsink 2 Soldering
TEC 3 Heatsink Gluing
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 5 of 5