Thermoelectric Module Datasheets
RMT Ltd
Thermoelectric module type 1ML06-023-xx is available in four different ceramics versions. Cost-effective Al2O3 ceramics versions or high performance AlN ceramics versions are available. Please, select the appropriate type to check the complete datasheet.
1ML06-023-xx
1ML06-023-xxt
1ML06-023-xxAN025
1ML06-023-xxAN05
RMT Standard Al2O3 0.5mm ceramics version. TEC total height from 1.6mm to 2.4mm
RMT Special Thin Al2O3 0.25mm ceramics version. TEC total height from 1.1mm to 1.9mm
RMT Standard AlN 0.25mm ceramics version. TEC total height from 1.1mm to 1.9mm
RMT Special Version with thick AlN 0.5mm ceramics. TEC total height from 1.6mm to 2.4mm
Thermoelectric Sub-Mounts (TEC + Package assembled) are available
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 1 of 1
Thermoelectric Module Datasheet
Performance Parameters
ΔTmax K Qmax W Imax A Umax V AC R Ohm H mm h mm
RMT Ltd
1ML06-023-XX
Type
1ML06-023-xx (N=23) Al2O3 0.5mm ceramics version 1ML06-023-05 1ML06-023-09 1ML06-023-12 69 71 71 5.2 3.1 2.3 3.4 2.0 1.5 2.8 0.68 1.20 1.60 1.7 2.1 2.4 0.5 0.9 1.2
Performance data are given at 300K, vacuum
Technical Drawing
Options available
A. TEC Assembly: Solder Sn-Sb (Tmelt=230°C) C. Ceramics Surface Options D. Thermistor (optional) 1. Blank ceramics Can be mounted to cold side 2. Metallized: ceramics edge. Calibration 2.1 Ni / Sn(Bi) B. Ceramics: is available. 2.2 Gold plating 1.Pure Al2O3(100%) 3. Metallized and pre-tinned: 2.Alumina (Al2O3 - 96%) E. Terminal wires 3.1 Solder 94 (Pb-Sn-Bi, Tmelt=94°C) 3.Aluminum Nitride (AlN) 1. Pre-tinned Copper 3.2 Solder 117 (In-Sn, Tmelt=117°C) 2. Insulated Wires 3.3 Solder 138 (Sn-Bi, Tmelt=138°C) 100% Al2O3 used as standard 3. Insulated Color Coded 3.4 Solder 183 (Pb-Sn, Tmelt=183°C)
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 1 of 3
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1ML06-023-05
Performance Plots
1ML06-023-09
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 2 of 3
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1ML06-023-12
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax
Application Tips
1. Never heat TE module more than 200˚C (TEC assembled at 230˚C). 2. Never use TE module without attached heat sink at hot (bottom) side. 3. Connect TE module to DC power supply according to polarity. 4. Do not apply DC current higher than Imax.
Installation
1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types require other assembling methods in most cases. 2. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option and also makes pre-tinning for TE modules. 3. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good thermoconductive properties. A glue is usually based on some epoxy compound filled with some thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a specific type depends on application features and the type of a TE module.
Object being cooled Object being cooled
TEC 1 Screw mounting Heatsink 2 Soldering
TEC 3 Heatsink Gluing
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 3 of 3
Thermoelectric Module Datasheet
Performance Parameters
ΔTmax K Qmax W Imax A Umax V AC R Ohm H mm h mm
RMT Ltd
1ML06-023-XXt
Type
1ML06-023-xxt (N=23) Al2O3 0.25mm ceramics version 1ML06-023-05t 1ML06-023-09t 1ML06-023-12t 69 71 71 5.2 3.1 2.3 3.4 2.0 1.5 2.8 0.68 1.20 1.60 1.2 1.6 1.9 0.5 0.9 1.2
Performance data are given at 300K, vacuum
Technical Drawing
Options available
A. TEC Assembly: Solder Sn-Sb (Tmelt=230°C) C. Ceramics Surface Options D. Thermistor (optional) 1. Blank ceramics Can be mounted to cold side 2. Metallized: ceramics edge. Calibration 2.1 Ni / Sn(Bi) B. Ceramics: is available. 2.2 Gold plating 1.Pure Al2O3(100%) 3. Metallized and pre-tinned: 2.Alumina (Al2O3 - 96%) E. Terminal wires 3.1 Solder 94 (Pb-Sn-Bi, Tmelt=94°C) 3.Aluminum Nitride (AlN) 1. Pre-tinned Copper 3.2 Solder 117 (In-Sn, Tmelt=117°C) 2. Insulated Wires 3.3 Solder 138 (Sn-Bi, Tmelt=138°C) 100% Al2O3 used as standard 3. Insulated Color Coded 3.4 Solder 183 (Pb-Sn, Tmelt=183°C)
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 1 of 3
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1ML06-023-05t
Performance Plots
1ML06-023-09t
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 2 of 3
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1ML06-023-12t
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax
Application Tips
1. Never heat TE module more than 200˚C (TEC assembled at 230˚C). 2. Never use TE module without attached heat sink at hot (bottom) side. 3. Connect TE module to DC power supply according to polarity. 4. Do not apply DC current higher than Imax.
Installation
1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types require other assembling methods in most cases. 2. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option and also makes pre-tinning for TE modules. 3. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good thermoconductive properties. A glue is usually based on some epoxy compound filled with some thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a specific type depends on application features and the type of a TE module.
Object being cooled Object being cooled
TEC 1 Screw mounting Heatsink 2 Soldering
TEC 3 Heatsink Gluing
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 3 of 3
Thermoelectric Module Datasheet
Performance Parameters
ΔTmax K Qmax W Imax A Umax V AC R Ohm H mm h mm
RMT Ltd
1ML06-023-XXAN
Type
1ML06-023-xxAN (N=23) AlN 0.25mm ceramics version
1ML06-023-05AN 1ML06-023-09AN 1ML06-023-12AN
70 72 72
5.7 3.2 2.4
3.5 2.0 1.5 2.9
0.68 1.20 1.60
1.2 1.6 1.9
0.5 0.9 1.2
Performance data are given at 300K, vacuum
Technical Drawing
Options available
A. TEC Assembly: Solder Sn-Sb (Tmelt=230°C) B. Ceramics: 1.Pure Al2O3(100%) 2.Alumina (Al2O3 - 96%) 3.Aluminum Nitride (AlN) 100% AlN used as standard C. Ceramics Surface Options D. Thermistor (optional) 1. Blank ceramics Can be mounted to cold side 2. Metallized: ceramics edge. Calibration 2.1 Ni / Sn(Bi) is available. 2.2 Gold plating 3. Metallized and pre-tinned: E. Terminal wires 3.1 Solder 94 (Pb-Sn-Bi, Tmelt=94°C) 1. Pre-tinned Copper 3.2 Solder 117 (In-Sn, Tmelt=117°C) 2. Insulated Wires 3.3 Solder 138 (Sn-Bi, Tmelt=138°C) 3. Insulated Color Coded 3.4 Solder 183 (Pb-Sn, Tmelt=183°C)
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 1 of 3
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1ML06-023-05AN
Performance Plots
1ML06-023-09AN
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 2 of 3
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1ML06-023-12AN
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax
Application Tips
1. Never heat TE module more than 200˚C (TEC assembled at 230˚C). 2. Never use TE module without attached heat sink at hot (bottom) side. 3. Connect TE module to DC power supply according to polarity. 4. Do not apply DC current higher than Imax.
Installation
1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types require other assembling methods in most cases. 2. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option and also makes pre-tinning for TE modules. 3. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good thermoconductive properties. A glue is usually based on some epoxy compound filled with some thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a specific type depends on application features and the type of a TE module.
Object being cooled Object being cooled
TEC 1 Screw mounting Heatsink 2 Soldering
TEC 3 Heatsink Gluing
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 3 of 3
Thermoelectric Module Datasheet
Performance Parameters
ΔTmax K Qmax W Imax A Umax V AC R Ohm H mm h mm
RMT Ltd
1ML06-023-XXAN
Type
1ML06-023-xxAN (N=23) AlN 0.5mm ceramics version
1ML06-023-05AN 1ML06-023-09AN 1ML06-023-12AN
70 72 72
5.7 3.2 2.4
3.5 2.0 1.5 2.9
0.68 1.20 1.60
1.7 2.1 2.4
0.5 0.9 1.2
Performance data are given at 300K, vacuum
Technical Drawing
Options available
A. TEC Assembly: Solder Sn-Sb (Tmelt=230°C) B. Ceramics: 1.Pure Al2O3(100%) 2.Alumina (Al2O3 - 96%) 3.Aluminum Nitride (AlN) 100% AlN used as standard C. Ceramics Surface Options D. Thermistor (optional) 1. Blank ceramics Can be mounted to cold side 2. Metallized: ceramics edge. Calibration 2.1 Ni / Sn(Bi) is available. 2.2 Gold plating 3. Metallized and pre-tinned: E. Terminal wires 3.1 Solder 94 (Pb-Sn-Bi, Tmelt=94°C) 1. Pre-tinned Copper 3.2 Solder 117 (In-Sn, Tmelt=117°C) 2. Insulated Wires 3.3 Solder 138 (Sn-Bi, Tmelt=138°C) 3. Insulated Color Coded 3.4 Solder 183 (Pb-Sn, Tmelt=183°C)
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 1 of 3
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1ML06-023-05AN
Performance Plots
1ML06-023-09AN
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 2 of 3
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1ML06-023-12AN
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax
Application Tips
1. Never heat TE module more than 200˚C (TEC assembled at 230˚C). 2. Never use TE module without attached heat sink at hot (bottom) side. 3. Connect TE module to DC power supply according to polarity. 4. Do not apply DC current higher than Imax.
Installation
1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types require other assembling methods in most cases. 2. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option and also makes pre-tinning for TE modules. 3. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good thermoconductive properties. A glue is usually based on some epoxy compound filled with some thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a specific type depends on application features and the type of a TE module.
Object being cooled Object being cooled
TEC 1 Screw mounting Heatsink 2 Soldering
TEC 3 Heatsink Gluing
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 3 of 3