Thermoelectric Module Datasheet
Performance Parameters
Type ΔTmax K Qmax W Imax A Umax V AC R Ohm H mm h mm
RMT Ltd
1ML06-023-XXAN
1ML06-023-xxAN (N=23) AlN 0.5mm ceramics version
1ML06-023-05AN 1ML06-023-07AN 1ML06-023-09AN 1ML06-023-12AN
70 71 72 72
5.7 4.0 3.2 2.4
3.5 2.4 2.0 1.5 2.9
0.68 0.90 1.20 1.60
1.7 1.9 2.1 2.4
0.5 0.7 0.9 1.2
Performance data are given at 300K, vacuum
Technical Drawing
Options available
A. TEC Assembly: Solder Sn-Sb (Tmelt=230°C) B. Ceramics: 1.Pure Al2O3(100%) 2.Alumina (Al2O3 - 96%) 3.Aluminum Nitride (AlN) 100% AlN used as standard C. Ceramics Surface Options D. Thermistor (optional) 1. Blank ceramics Can be mounted to cold side 2. Metallized: ceramics edge. Calibration 2.1 Ni / Sn(Bi) is available. 2.2 Gold plating 3. Metallized and pre-tinned: E. Terminal wires 3.1 Solder 94 (Pb-Sn-Bi, Tmelt=94°C) 1. Pre-tinned Copper 3.2 Solder 117 (In-Sn, Tmelt=117°C) 2. Insulated Wires 3.3 Solder 138 (Sn-Bi, Tmelt=138°C) 3. Insulated Color Coded 3.4 Solder 183 (Pb-Sn, Tmelt=183°C)
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 1 of 4
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1ML06-023-05AN05
Temperature difference, K
Current, A
Temperature difference, K
Heat Pumped at the Cold Side, W
Voltage, V
Temperature difference, K
C.O.P
Temperature difference, K
Performance Plots
1ML06-023-07AN05
Temperature difference, K
Current, A
Temperature difference, K
Heat Pumped at the Cold Side, W
Voltage, V
Temperature difference, K
C.O.P
Temperature difference, K
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 2 of 4
Thermoelectric Module Datasheet
Performance Plots
RMT Ltd
1ML06-023-09AN05
Temperature difference, K
Current, A
Temperature difference, K
Heat Pumped at the Cold Side, W
Voltage, V
Temperature difference, K
C.O.P
Temperature difference, K
Performance Plots
1ML06-023-12AN05
Temperature difference, K
Current, A
Temperature difference, K
Heat Pumped at the Cold Side, W
Voltage, V
Temperature difference, K
C.O.P
Temperature difference, K
Color Legend: Imax, 0.8 Imax, 0.6 Imax, 0.4 Imax 53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 3 of 4
Thermoelectric Module Datasheet
RMT Ltd
Application Tips
1. Never heat TE module more than 200˚C (TEC assembled at 230˚C). 2. Never use TE module without attached heat sink at hot (bottom) side. 3. Connect TE module to DC power supply according to polarity. 4. Do not apply DC current higher than Imax.
Installation
1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types require other assembling methods in most cases. 2. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option and also makes pre-tinning for TE modules. 3. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good thermoconductive properties. A glue is usually based on some epoxy compound filled with some thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a specific type depends on application features and the type of a TE module.
Object being cooled
Object being cooled
TEC 1 Screw mounting Heatsink 2 Soldering
TEC 3 Heatsink Gluing
53 Leninskij prosp. Moscow 119991 Russia, ph: +7-499-132-6817, fax: +7-499-783-3664, web: www.rmtltd.ru
Copyright 2008. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 4 of 4