Data Sheet
100VAC Input/15VDC (200mA) Output
Non-Isolated AC/DC Converter
BP5039-15
Absolute Maximum Ratings
Parameter Input voltage Maximum output current ESD endurance Operating temperature range Storage temperature range Symbol Vi IoMAX Vsurge Topr Tstg Limits 170 200 2 −25 to +80 −25 to +105 Unit V mApk kV °C °C
Dimensions (Unit : mm)
35.0MAX. Mark Side 1 3 5 7 7.62 1 . 3 ±0 . 2 2.54�11=27.94 10 12 0 . 2 5 ±0 . 0 5 4.85MAX. 4.25MAX. 0 . 5 ±0 . 1 3.6MAX 5.08 9.1MAX. 19.5MAX.
Electrical Characteristics
Parameter Symbol Min. Input voltage range 113 Vi Output voltage 14.25 Vo Output current 0 Io Line regulation −0.20 Vr Load regulation −0.20 Vl Output ripple voltage − Vp Power conversion efficiency 60 η Surface temperature rising − Tc Output current overcurrent1 Im 240 Output current overcurrent2 Is − Typ. 141 15.00 − 0.05 0.05 0.07 74 38 270 260 Max. 170 15.75 200 0.20 0.20 0.15 − − − 290 Unit V V mA V V Vp-p % K mA mA Conditions DC(80 to 120VAC) Vi=141V, Io=100mA Vi=141V ∗1 Vi=113 to 170V, Io=100mA Vi=141V, Io=0 to 100mA ∗2 Vi=141V, Io=100mA Vi=141V, Io=200mA ∗2 Vi=170V, Io=200mA Vi=141V Vi=141V
Derating Curve
250 Output Current Io(mA) 200 150 100 50 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 Ambient Temperature Ta(°C) Operation Range Derating Curve
Switching Frequency
45 40 35 30 25 20 15 10 5 0 0 Switching Frequency (Ta=25°C, Vi=141V) Switching Frequency(kHz)
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Please refer to Load regulation, Conversion efficiency.
Application Circuit
BP5039-15
Be sure to use fuse for safety.
Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Function Output terminal Vo(15V) Skip Choke coil connect Skip Choke coil connect Skip COMMON Skip Skip N.C. Skip Input terminal Vi(141VDC)
4±1.0
50 100 150 Output Current Io(mA)
200
12 10
DC motor
Ii Vi D1
+
7531
R1 C1
FUSE Io C3 L1 +
−
Conversion Efficiency
Conversion Efficiency η(%) 100 80 60 40 20 0 0 50 100 150 Output Current Io(mA) 200 Conversion Efficiency (Ta=25°C, Vi=141V)
ZNR
−
C2
Vo
Please verify operation and characteristics in the customer's circuit before actual usage. Ensure that the load current does not exceed the maximum rating. External Component Specifications FUSE: Fuse C1: Input capacitor C2: Output capacitor Please make sure to use quick acting fuse (1A) Above 250V, 22 to 820µF Ripple current 0.13Arms above Above 25V, 100 to 470µF, Low impedance ESR : 0.4Ω Max. Ripple current 0.25Arms above Impedance of capacitor effects the output ripple voltage. Above 250V, 0.1 to 0.22µF Use a film or ceramic capacitor. Evaluate under actual conditions. Inductance : 1mH, Rating current : above 600mA Choose components that do not easily get magnetically saturated at high temperature. Use a rectifying diode with a peak reverse voltage of 400V or higher, an average rectification current of 0.5A or larger and a peak surge current of 20A or larger. When using a large capacitance input capacitor select a component strong against inrush current during power up. Full-wave rectification can be used. 10 to 22Ω, 1/4W Determine the ideal value through actual testing. A varistor must be used to protect against lightning surges and static electricity.
Load Regulation
16 14 12 10 8 6 4 2 0 Load Regulation (Ta=25°C, Vi=141V) Output Voltage Vo(V)
C3: Noise reduction capacitor L1: Power inductor
0
50
100 150 200 250 Output Current Io(mA)
300
D1: Rectifier diode
Surface Temperature Increase
50 45 40 35 30 25 20 15 10 5 0
Temperature Rising ∆T(°C) Surface Temperature Increase (Ta=25°C, Vi=141V)
R1: Noise reduction resistor ZNR: Varistor
0
50 100 150 200 Output Current Io(mA)
250
www.rohm.com ©2010 ROHM Co., Ltd. All rights reserved.
1/1
2010.01 - Rev.A
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com © 2010 ROHM Co., Ltd. All rights reserved.
R1010A