0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BP5061-5

BP5061-5

  • 厂商:

    ROHM(罗姆)

  • 封装:

    -

  • 描述:

    IC AC/DC CONV -5V 350MA SIP12

  • 数据手册
  • 价格&库存
BP5061-5 数据手册
Data Sheet 100VAC Input/ −5VDC (350mA) Output Non-Isolated AC/DC Converter BP5061-5 Absolute Maximum Ratings Parameter Input voltage Output current ESD endurance Operating temperature range Storage temperature range Symbol Vi Io Vsurge Topr Tstg Limits −180 350 2 −25 to +80 −25 to +105 Unit V mApk kV °C °C Dimensions (Unit : mm) 35.0MAX. Mark Side 1 3 5 7 10 12 0 . 2 5 ±0 . 0 5 0 . 5 ±0 . 2 3.6MAX P = 5 . 0 8 ±0 . 2 1 . 3 ±0 . 2 7.62 ±0.3 4.85MAX. 4.25MAX. 2.54�11=27.94 9.1MAX. 19.5MAX. Electrical Characteristics Symbol Min. Parameter Input voltage range −113 Vi Output voltage −4.7 Vo Output current 0 Io Line regulation − Vr Load regulation − Vl Output ripple voltage − Vp Power conversion effciency 50 η Typ. −141 −5.0 − 0.04 0.05 0.07 62.1 Max. −180 −5.3 350 0.15 0.15 0.2 − Unit V V mA V V Vp-p % Conditions DC (80 to 120VAC) Vi=−141V, Io=200mA Vi=−141V ∗1 Vi=−113V to −180V, Io=200mA Vi=−141V, Io=0 to 200mA Vi=−141V, Io=200mA ∗2 Vi=−141V, Io=350mA Derating Curve Derating Curve 400 350 300 250 200 Operation Range 150 100 50 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 Ambient Temperature Ta(°C) Output Current Io(mA) ∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Spike noise is not included in output ripple voltage. Conversion Efficiency 100 90 80 70 60 50 40 30 20 10 0 0 Conversion Efficiency (Ta=25°C, Vi=−141V) Conversion Efficiency (%) Application Circuit BP5061-5 Please note that pin No.12 side is input. 12 R1 D1 1SR35-400 10Ω1/4W Input AC100V 50Hz/60Hz − ZNR 220V + 7 5 3 1 FUSE 1A C2 0.1µF L1 470µH − + Output −5V C3 Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Function Output terminal Vo(−5V) Not used Coil connect Not used Coil connect Not used COMMON Not used Not used N.C. Not used Input voltage Vi(−141VDC) 4±1.0 100 200 300 Output Current Io(mA) 400 Output current 5.3 Output Voltage Vo(V) 5.2 5.1 5.0 4.9 4.8 4.7 0 50 100 150 200 250 300 350 400 Output Current Io(mA) Output Current (Ta=25°C, Vi=−141V) C1 33µF/200V 220µF/50V Be sure to use fuse for safety. Please verify operation and characteristics in the customer's circuit before actual usage. Ensure that the load current does not exceed the maximum rating. External Component Specifications FUSE: Fuse C1: Input smoothing capacitor C2: Noise reduction resistor C3: Output smoothing capacitor D1: Rectifier diode Use a quick-acting fuse of 1A Capacitance : 33 to 100µF Rated voltage : 200V or higher Ripple current is 0.13Arms or above. Capacitance : 0.1 to 0.22µF Rated voltage : 250V or higher Use a film or ceramic capacitor. Evaluate under actual operating conditions. Capacitance : 220 to 470µF Rated voltage : 16V or higher, ESR is 0.4Ω max. Ripple current is 0.25Arms or above. Evaluate under actual operating conditions. In the absolute maximum ratings the reverse peak voltage should be 400V or higher, the average rectifying current should be 0.5A or higher, and the peak surge current should be 20A or higher. (Full-wave rectification can be used.) Coil for switching regulator. The inductance should be 470µH, the rated direct current should be 0.9A or above in order to prevent overheating and abnormal oscillation. 10 to 22Ω 1/4W Determine the ideal value through actual testing. A varistor is required to protect against lightning surges and static electricity. Surface Temperature Increase 50 45 40 35 30 25 20 15 10 5 0 Temperature Rising ∆T(°C) Surface Temperature Increase (Ta=25°C, Vi=−141V) 0 50 100 150 200 250 300 350 400 Output Current Io(mA) L1: Choke coil R1: Noise reduction resistor ZNR: Varistor www.rohm.com ©2010 ROHM Co., Ltd. All rights reserved. 1/1 2010.01 - Rev.A Notice Notes No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ www.rohm.com © 2010 ROHM Co., Ltd. All rights reserved. R1010A
BP5061-5 价格&库存

很抱歉,暂时无法提供与“BP5061-5”相匹配的价格&库存,您可以联系我们找货

免费人工找货
BP5061-5
    •  国内价格 香港价格
    • 1+16.721301+2.02272
    • 10+16.2595210+1.96686
    • 50+15.9597750+1.93060
    • 100+15.65191100+1.89336
    • 500+15.57900500+1.88454
    • 1000+15.546601000+1.88062

    库存:78