Absolute Maximum Ratings
Parameter Input voltage Operating temperature range Storage temperature range Case temperature Output current Symbol Vi Topr Tstg Tsmax Iopeak Limits −187 −20 to +80 −25 to +105 105 100 Unit V °C °C °C mApk
19.5MAX.
Dimensions (Unit : mm)
20.5MAX. 10.7MAX.
MARKING SIDE
4.0±1.0
1
0.5±0.1
456 7
P=2.54±0.2 1.3±0.2 4.45MAX. 0.25±0.05 6.25MAX.
Electrical Characteristics
Symbol Min. Parameter Input voltage −113 Vi Output voltage −11.7 Vo Output current − Io Line regulation − Vr Load regulation − Vl Output ripple voltage − Vp Conversion efficiency 68 η Typ. −141 −12.5 − 0.02 0.01 0.04 73 Max. −187 −13.2 100 0.20 0.20 0.20 − Unit V V mA V V Vp-p % Conditions DC Vi=−141V, Io=50mA
∗1
3.25MAX.
2.54x6=15.24TYP.
Derating Curve
120 Output Current Io(mA) 100 80 60 40 20 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature Ta(°C) Operation Range
Vi=−113 to −187V Vi=−141V, Io=0 to 50mA Vi=−141V, Io=50mA ∗2 Vi=−141V, Io=100mA
∗1 Max output current should be reduced according to the surrounding temperature. ∗2 The output ripple voltage may vary depending on the capacitance, environment, and location of peripheral components. Especially right attention has to be paid to aluminum electrolytic capacitor, because ESR changes greatly at the time of the low temperature and output ripple voltages increase.
Application Circuit
BP5075-12
Be sure to use fuse for safety.
1 4 5 6 7
Pin No. 1 2 3 4 5 6 7 Functions Input terminal Skip Skip COMMON COMMON NC Output terminal
Conversion Efficiency
Conversion Efficiency (%) 100 80 60 40 20 0 0 20 40 60 80 100 Output Current Io(mA) 120 Conversion Efficiency (Vi= −141V,Ta=25°C )
D1
R1
FUSE A
−
Vi ZNR
−
C1 C3 C2
−
V
+
+
−
Vo
Please verify operation and characteristics in the customer's circuit before actual usage. Ensure that the load current does not exceed the maximum rating.
Load Regulation
-14.0 Output Voltage Vo(V) -12.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 0 20 40 60 80 100 120 140 Output Current Io(mA) Maximum Io=100mA
Load Regulation ( Vi= −141V,Ta=25°C)
External Component Specifications FUSE: Fuse C1: Input capacitor C2: Output capacitor Use a quick-acting fuse (1.0A) above 250V, 10 to 47µF above 25V, 47 to 470µF, Low impedance ESR:0.42Ω Max. Ripple current 0.2Arms or greater Capacitor impedance affects the output ripple voltage. Above 250V, 0.1 to 0.22µF Film or ceramic capacitor. Evaluate under actual operating conditions. 10 to 100Ω, 1/4W Determine the ideal value through actual testing. Use a rectifying diode with a peak reverse voltage of 400V or higher, an average rectification current of 1A or larger and a peak surge current of 40A or larger. When using a large capacitance input capacitor, select a component that is strong against inrush current during power up. Full-wave rectification can be used. A varistor is required to protect against lightning surges and static electricity.
C3: Noise reduction capacitor
Temperature Curve
Surface Temperature Increase ∆T(°C)
R1: Noise reduction resistor D1: Rectifier diode
60 50 40 30 20 10 0
0
Surface Temperature Increase (Vi= −141V,Ta=25°C, )
20
ZNR: Varistor
40 60 80 100 Output Current Io(mA)
www.rohm.com ©2010 ROHM Co., Ltd. All rights reserved.
1/1
2010.01 - Rev.A
MARKING SIDE
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com © 2010 ROHM Co., Ltd. All rights reserved.
R1010A