Communication ICs
Dual PLL frequency synthesizer
BU2630F / BU2630FV
The BU2630F / BU2630FV are a CMOS LSI with an internal dual PLL synthesizer. VCOs for transmission and reception can be controlled independently, and the reference frequency and main counter settings can also be programmed separately. This product is designed for applications involving cordless telephones and communications equipment worldwide. FApplications Cordless telephones, amateur short wave radios, industrial transceivers, VHF / UHF frequency generators, and others FFeatures 1) Operation possible at up to 80MHz (VDD = 2.5). 2) Low current dissipation Dual-system operation : 2.2mA (typ), VDD = 3V Single-system operation : 1.2mA (typ), VDD = 3V Non-operating state : 0.2mA (typ), VDD = 3V FBlock diagram
3) 4) 5) 6) 7)
16-bit main counter. Internal 14-bit reference frequency counter. Unlock detection possible. Four output ports. (open drain) Control possible using 3-wire serial input.
91
Communication ICs
FAbsolute maximum ratings (Ta = 25_C)
BU2630F / BU2630FV
FRecommended operating conditions (Ta = 25_C)
FPin descriptions
92
Communication ICs
FInput / output circuits
BU2630F / BU2630FV
93
Communication ICs
BU2630F / BU2630FV
FElectrical characteristics (unless otherwise noted, Ta = 25_C, VDD = 3.0V, VSS = 0V)
94
Communication ICs
FCircuit operation
BU2630F / BU2630FV
95
Communication ICs
BU2630F / BU2630FV
Description of data (1) Programmable divider data: D0 X D15
(2) Reference frequency data: R0 X R13
(3) Output port control data : P-T (P-R) TON (RON) 1 : Open drain output ON (LO) 0 : Open drain output OFF (HI) (4) OFF transmission side (reception side) : Operation stopped F - T (F - R) pull-down : TPD (RPD) high-impedance, LD = OFF (5) PS Programmable device change : No. of divisions = 3 X 4095
96
Communication ICs
(6) PL, PH, and PD pin control 0 0 : PLL operation 1 0 : Forced LO state 0 1 : Forced HI state 1 1 : Forced LO state (7) LD0, LD1, LD pin control (valid only on TX side) 0 0 : ON when unlocked (LO) 0 1 : Air pulse output 1 0 : Forced ON state (LO) 1 1 : Forced OFF state (HI) (8) Input (00) to test T0 and T1. FApplication example
BU2630F / BU2630FV
97
Communication ICs
FElectrical characteristic curves
BU2630F / BU2630FV
FExternal dimensions (Units: mm)
98
很抱歉,暂时无法提供与“BU2630FV”相匹配的价格&库存,您可以联系我们找货