PB
Unit type
Ordering information
PBA150F
R
PB
1 2
A
3
150
4
F
5
-5
6
-O
Recommended Noise Filter NAC-06-472
High voltage pulse noise type : NAP series Low leakage current type : NAM series
*The Noise Filter is recommended *to connect with several devices.
1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional C :with Coating G :Low leakage current (0.15mA max / ACIN 240V) E :Low leakage current and EMI class A (0.5mA max / ACIN 240V) T :Vertical terminal block J :Connector type (Only -12,-15,-24,-36,-48) R :with Remote ON/OFF N :with Cover (Only 24V UL508 is acquired) N1 :with DIN rail V :Output voltage setting potentiometer externally
Cover is optional
MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PBA150F-3R3 PBA150F-5 99 150 3.3V 30A 5V 30A PBA150F-9 150.3 9V 16.7A PBA150F-12 156 12V 13A PBA150F-15 150 15V 10A PBA150F-24 156 24V 6.5A PBA150F-36 154.8 36V 4.3A PBA150F-48 158.4 48V 3.3A
SPECIFICATIONS
MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] INPUT ACIN 100V ACIN 200V ACIN 100V POWER FACTOR(Io=100%) ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C DRIFT[mV] *2 START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT -RC *3 INPUT-FG OUTPUT-RC-FG *3 OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS (At only AC input) CONDUCTED NOISE CE MARKING HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] ACIN 100V ACIN 200V PBA150F-3R3 PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input 1.3typ 2.0typ 0.7typ 1.0typ 50/60 (47 - 63) 80typ 83typ 82typ 83typ 84typ 85typ 82typ 86typ 85typ 86typ 87typ 88typ 0.98typ 0.99typ 0.87typ 0.93typ 20typ (Io=100%) (At cold start) 40typ (Io=100%) (At cold start) 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN) 3.3 5 9 12 15 24 30 30 16.7 13 10 6.5 20max 20max 36max 48max 60max 96max 40max 40max 100max 100max 120max 150max 80max 80max 120max 120max 120max 120max 140max 140max 160max 160max 160max 160max 120max 120max 150max 150max 150max 150max 160max 160max 180max 180max 180max 180max 50max 50max 90max 120max 150max 240max 60max 60max 120max 150max 180max 290max 20max 20max 36max 48max 60max 96max 350typ(ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 Works over 105% of rated current and recovers automatically 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 LED (Green) Optional (Only -3R3, -5 Option -K) Optional (Required external power source) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Low Voltage Directive, EMC Directive Complies with IEC61000-3-2 34X93X168mm (without terminal block) (WXHXD) / 560g max (without cover) Convection
* * * Parallel operation with other model is not possible. Derating is required when operated with cover. A sound may occur from power supply at peak loading.
PBA150F-36 voltage *4)
PBA150F-48
85typ 88typ
85typ 88typ
OUTPUT
36 4.3 144max 240max 150max 200max 250max 300max 360max 450max 144max
48 3.3 192max 240max 150max 200max 250max 300max 480max 600max 192max
28.8 - 39.6 36.00 - 37.44 43.0 - 50.0
39.0 - 53.0 48.00 - 49.92 58.0 - 65.0
PROTECTION CIRCUIT AND OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND NOISE REGULATIONS OTHERS
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and FG. Distribution: *4 Derating is required.
A-16
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de
■ ■ ■ ■ ■
Änderungen vorbehalten / subject to change without notice
PBA150F
Block diagram
PB
FUSE
250V4A AC IN 85 - 264V
NOISE FILTER
RECTIFIER
INRUSH CURRENT LIMIT
FG
CURRENT SENSING
OPTION
RC
EXTERNAL SOURCE
BOOSTER INDUCTER
CURRENT SENSING RECTIFIER AND FILTER CONTROL CONTROL
E
INVERTER INVERTER TRANSFORMER CONTROL
OVER VOLTAGE PROTECTION
RECTIFIER AND FILTER
DC OUT
External view
¶ External size of option T,J,R,N,N1,V and K is different from standard model and refer to 7 Option of instruction manual for details.
CN3 Connector for Remote ON/OFF (option) CN4 Connector for Remote sensing (option : only -3R3, -5) (13.5) LED 12 168 0.5 8.6 93 Cover (option)
(20.5) Voltage adjust (11.5)
+V +V -V (81) -V FG( )
M4
AC(L) AC(N) (10) 10
37.5
2-M3 Mounting hole
A Point A
(14.5) (24)
Terminal cover
TB1
78 ±0.5
58.5
2-M3 Mounting hole 3.5
Connector type
CN3 Option (Mfr : J.S.T.) Pin No. 1 2 Contents RC(+) RC( - )
Name plate
PBA150F 19
34
Barrier strip type
Model B2B-XH-A Mating Connector (Terminal) XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6
¶ Tolerance : ±1 ¶ Mass : 560g or less (without cover) ¶ PCB Material/thickness : CEM3 / 1.6mm ¶ Chassis material : Aluminum ¶ Dimensions in mm ¶ Mounting torque : 0.49N • m(5kgf • cm)max ¶ Mounting torque : M4:1.6N • m(16.9kgf • cm)max ¶ Keep drawing current per pin below 20A for TB1. ¶ Please connect safety ground to FG terminal on the unit.
■
139.5 ±0.5
9
(
)
Distribution: RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de
■ ■ ■ ■
A-17
Änderungen vorbehalten / subject to change without notice