Mess toyogawa
ALUMINUM ELECTROLYTIC CAPACITORS
SPECIFICATION SHEET
CUSTOMER
PART No.
Rubycon
PART No.
400 YXA 1 M PCS T1 6.3X11
DRAWING No.
REE – 114486
ISSUE DATE
10 December 2013
ISSUE No.
1
RUBYCON CORPORATION
ENGINEERING DIVISION
1938-1, NISHIMINOWA, INA-SHI, NAGANO-KEN, JAPAN
TEL No. 0265-72-7116
FAX No. 0265-73-3380
YUICHI KOBAYASHI
DESIGN
TETSUYA MIZU
CHECK
HIROKAZU KOUMURA
APPROVAL
PAGE
ALUMINUM ELECTROLYTIC
CAPACITORS
400 WV
1.Dimensions
1 MFD
Style
Operating Temperature Range
Reference Standard
1 Sleeve
2 Case
(YXA SERIES)
3 Lead Wire
1/6
CE 04
-25C ~ +105C
JIS C 5141 , JIS C 5102
P.E.T.
Aluminum
CP Wire
Tin plated
unit : mm
2
3
d+/-0.05
F+/- 0.5
1
L+2.0MAX
2.Electrical Performance
Table-1
CAPACITANCE
NOMINAL
TOLERANCE
CAPACITANCE
(%)
(F)
20C, 120Hz
1
4MIN
15MIN
SURGE
VOLTAGE
(V.DC)
RATED
VOLTAGE
(V.DC)
-20 ~ +20
400
450
D
LEAKAGE
CURRENT
(A MAX)
20C
1min
5min
80.0
27.0
DIMENSIONS
(mm)
IMPEDANCE
RATIO
120Hz
Z-25C/Z20C
D
L
F
d
6
6.3
11
2.5
0.5
3.Marking : Unless otherwise specified, capacitor shall be clearly marked the following items on its body.
Sleeve color : Black
Lettering color : White
(1) Trade mark
(2) Rated Voltage
400V
(3) Nominal Capacitance
1 F
(4) Polarity
(Negative Polarity)
(5) Series
YXA
(6) Lot. No.
(7) Maximum Operating temperature
(8) PET sleeve mark
105C
PET
4.Vent
A safety vent shall be provided.
YXA
SERIES
RUBYCON CORPORATION
+0.5MAX
D.F.
tan
MAX
20C
120Hz
MAX RIPPLE
CURRENT
(mA rms)
105C
120Hz
0.24
16
PAGE
2/6
5.Load Life test
Capacitor under test shall be applied the rated voltage continuously through 1000 ohm series protective resistor (with maximum ripple
current) at 1052C. After 2000 720 hours, capacitor shall be stored in standard condition for 2 hours or more, then capacitor shall meet
following requirement.
Capacitance Change : within 25% of the initially measured value.
Dissipation Factor
: less than 200% of the specified value.
Leakage Current
: less than the specified value.
Appearance
: notable changes shall not be found.
(Except sleeve condition)
6.Shelf life test
Capacitors shall be stored at 1052C with no voltage applied for 1000 480 hours. After the test and returned in standard condition for 1 to 2
hours and the capacitor shall meet following requirements. (If any doubt arises on the judgment, the capacitors shall be subjected to voltage
treatment specified in JIS C 5141,5.2.)
Capacitance Change : within 25% of the initially measured value.
Dissipation Factor
: less than 200% of the specified value.
Leakage Current
: less than the specified value.
Appearance
: notable changes shall not be found.
7.Correction factor for ripple current
The maximum permissible ripple current is the maximum A.C. current at 120Hz and can be applied at maximum operating temperature.
The combined value of D.C. voltage and the peak A.C. voltage shall not exceed the rated voltage and shall not be reverse voltage.
< Frequency Coefficient >
Freq. (Hz)
60(50)
120
500
1k
10k
Multiplier
0.50
1.00
1.20
1.30
1.50
< Temperature Coefficient >
Ambient Temperature(C)
105
85
65
Coefficient
1.0
1.7
2.1
Temperature coefficient shows a limit of ripple current exceeding the rated ripple current that can be passed through a capacitor at each
temperature when the life expectancy of a capacitor becomes to be nearly equal with the lifetime at the rated maximum operating
temperature.
Ripple voltage with wide amplitude
Use of aluminum electrolytic capacitor under ripple voltage with wide amplitude is equivalent to quick charge-discharge operation.
When ripple voltage with the amplitude over 70Vp-p is expected for the products with rated voltage over 100V, please contact us.
8.Operation of safety vent (S-measure)
Capacitors (The examination number:10) shall be added DC overvoltage(WV×1.5) below by using DC constant power supply at5-35deg.C.
Maximum D.C. Current is 1A
After test either of the following specification shall be satisfied.
*When the safety vent does not open even 10 minutes after beginning this test the test may be ended.
*Even if electrolyte was discharged after a pressure relief vent of capacitor had operated. the percentage of capacitors without
short-circuit (normal vent operation)shall be more than 60%.The percentage of normal vent operation shall be more than 80% on an
accumulation of regular test.
YXA
SERIES
RUBYCON CORPORATION
PAGE
3/6
9. Notes on use of aluminum electrolytic capacitors
(1) Charge and discharge
Do not use for the circuit that repeats quick charge or discharge
(2) External stress
Do not apply excessive force of pushing, pulling bending, and/or twisting to the main body, lead wire and terminals.
(3) Heat resistance at soldering process
In the soldering process of PC board with Capacitors mounted, secondary shrinkage or crack of sleeve may be observed when
soldering temperature is too high and /or soldering time is too long.
If lead wire of other components or pattern of double sided PC board touches the capacitor, the similar failure may be also originated at
pre-heating, heating at hardening process of adhesive and soldering process.
(4) Insulation and PC board mounting
Sleeve is for marking purpose only. It is not recognized as insulation materials.
When double sided PC board is employed, note that it could cause a short circuit if lead wire of other components or pattern of double
sided PC board touches capacitor. Please avoid circuit pattern runs underneath capacitor.
In addition, case and cathode terminal are not insulated.
(5) Adhesives and coating materials
Do not use the adhesives and coating materials that contain halogenated organic solvents or chloroprene as polymer.
(6) Storage
Keep at a normal temperature and humidity. During a long storage time, leakage current will be increased. To prevent heat rise or any
trouble that high leakage current possibly causes, voltage treatment is recommended for the capacitors that have been stored for a long
time.
.
*Aluminum electrolytic capacitors should not be stored in high temperatures or where there is a high level of humidity. The suitable
storage condition is 5C-35C and less than 75% in relative humidity.
*Aluminum electrolytic capacitors should not be stored in damp conditions such as water, saltwater spray or oil spray.
*Do not store aluminum electrolytic capacitors in an environment full of hazardous gas (hydrogen sulfide, sulfurous acid gas, nitrous
acid, chlorine gas, ammonia or bromine gas).
*Aluminum electrolytic capacitors should not be stored under exposure to ozone, ultraviolet rays or radiation.
(7) Fumigation and halogenated flame retardant
It may cause corrosion of internal electrodes, aluminum cases and terminal surface when the following conditions exist.
*Fumigation of wooden pallets before shipment to disinfect vermin.
*Existence of components or parts that contain halogenated flame retardant agent (bromine etc.) together with capacitors.
*When halogenated detergents or antiseptics for preventing infection of epidemic diseases contact directly to capacitors.
(8) PC board cleaning after soldering
Please consult us when cleaning is subjected.
Guide to application except the above are described in our catalog and EIAJ RCR-2367C.
EIAJ RCR-2367C: “Safety Application Guide for fixed aluminum electrolytic capacitors for use in electronic equipment."
Published by Japan Electronics and Information Technology Industries Association.
YXA
SERIES
RUBYCON CORPORATION
PAGE
4/6
TAPING SPECIFICATION OF RADIAL LEAD TYPE ALUMINUM ELECTROLYTIC CAPACITORS
1.Scope
This specification covers taped radial lead type electrolytic capacitors, with case dia of 6.3 mm.
2.Requirements.
2-1. Body tape requirements are shown in 6/6 page.
2-2. All polarized capacitors must be oriented in one direction.
2-3. Leader tape shall be provided before the first capacitor and after the last one on tape at minimum
length of 3 feed holes.
2-4 Maximum of 3 consecutive missing capacitors are permitted while one pack quantity meets the
specification in para.4.
2-5. Mounting tape shall be spliced as shown in Fig.1. Mounting tape shall not be over lapped.
lead wire
adhesive tape
mounting tape
Fig.1
splicing tape
mounting tape
connection of adhesive tape
connection of mounting tape
2-6. Defective capacitors shall be pulled out or clipped from the mounting tape.
Remaining protrusion of the leads shall not exceed 2mm from edge of the tape, when clipped.
3. Adhesion test of mounting tape
3-1. Adhesive tape on the mounting tape shall not a tear off at the force of less than 3N {0.3kgf} when
tested in a manner shown in Fig.2.
3-2. Capacitors shall not be pulled out of the tape with a following load applied to the capacitor body in a
manner shown in Fig.3.
Dia 8mm 10N {1.0kgf}
push-pull scale
pull force
adhesive tape
Fig.2
YXA
SERIES
pull force
mounting tape
(to fixed)
RUBYCON CORPORATION
fixed
Fig.3
PAGE
4.Package
Taped capacitors shall be packed in a carton shown in Fig.4, with tape ammunition.
Packed cartons shall be marked at least polarity, rated voltage, nominal capacitance and quantity.
330 MAX
WP MAX
340 MAX
Fig.4
STANDARD PACKING QUANTITY
YXA
SERIES
CASE DIA
QUANTITY
WP(mm)
6.3X11
2000
54
RUBYCON CORPORATION
5/6
PAGE
CODE
:
T1
6/6
( Positive leading )
LEAD TYPE ( DIA. 6.3 )
p
p2
h h
p p
L
D
H
d
F
w1
w0
p0
D0
t
L1
w
w2
p1
Symbol
d
L
P
P0
P1
P2
F
W
W0
W1
W2
H
L1
D0
h
p
t
YXA
Case Dia mm
6.3
0.5
0.05
13.0
MAX
12.7
1.0
12.7
0.2
5.1
0.5
6.35 1.0
0.8
2.5
0.2
18.0
0.3
5.0
MIN
9.0
0.5
1.5
MAX
18.5
0.75
0.5
MAX
4.0
0.2
1.0
MAX
1.0
MAX
0.6
0.3
SERIES
Remarks
Dia of lead
Height of body
Distance from center to center of body
Distance from center to center of driving hole
Distance between center of driving hole and lead
Distance between center of driving hole and body
Lead spacing
Width of mounting tape
Width of adhesive tape
Distance between center of driving hole and edge of mounting tape
Max. allowable distance between mount and adhesive tape side
Distance between center of driving hole and bottom of body
Protrusion of lead
Dia. of driving hole
Off alignment of body
Off alignment of body
Sum of thickness for mounting and adhesive tape without lead dia.
RUBYCON CORPORATION
400YXA1MPCST16.3X11 价格&库存
很抱歉,暂时无法提供与“400YXA1MPCST16.3X11”相匹配的价格&库存,您可以联系我们找货
免费人工找货