74AUP3G07
Low-power triple buffer with open-drain output
Rev. 2 — 5 October 2016
Product data sheet
1. General description
The 74AUP3G07 is a triple non-inverting buffer with open-drain output. The output of the
device is an open drain and can be connected to other open-drain outputs to implement
active-LOW wired-OR or active-HIGH wired-AND functions.
Schmitt-trigger action at all inputs makes the circuit tolerant to slower input rise and fall
times across the entire VCC range from 0.8 V to 3.6 V.
This device ensures a very low static and dynamic power consumption across the entire
VCC range from 0.8 V to 3.6 V.
This device is fully specified for partial power-down applications using IOFF.
The IOFF circuitry disables the output, preventing the damaging backflow current through
the device when it is powered down.
2. Features and benefits
Wide supply voltage range from 0.8 V to 3.6 V
High noise immunity
Complies with JEDEC standards:
JESD8-12 (0.8 V to 1.3 V)
JESD8-11 (0.9 V to 1.65 V)
JESD8-7 (1.2 V to 1.95 V)
JESD8-5 (1.8 V to 2.7 V)
JESD8-B (2.7 V to 3.6 V)
ESD protection:
HBM JESD22-A114F Class 3A exceeds 5000 V
MM JESD22-A115-A exceeds 200 V
CDM JESD22-C101E exceeds 1000 V
Low static power consumption; ICC = 0.9 A (maximum)
Latch-up performance exceeds 100 mA per JESD 78B Class II
Inputs accept voltages up to 3.6 V
Low noise overshoot and undershoot < 10 % of VCC
IOFF circuitry provides partial Power-down mode operation
Multiple package options
Specified from 40 C to +85 C and 40 C to +125 C
74AUP3G07
Nexperia
Low-power triple buffer with open-drain output
3. Ordering information
Table 1.
Ordering information
Type number
Package
Temperature range
Name
Description
Version
74AUP3G07DC
40 C to +125 C
VSSOP8
plastic very thin shrink small outline package; 8 leads; SOT765-1
body width 2.3 mm
74AUP3G07GT
40 C to +125 C
XSON8
plastic extremely thin small outline package; no leads; SOT833-1
8 terminals; body 1 1.95 0.5 mm
74AUP3G07GM
40 C to +125 C
XQFN8
plastic, extremely thin quad flat package; no leads;
8 terminals; body 1.6 1.6 0.5 mm
SOT902-2
74AUP3G07GN
40 C to +125 C
XSON8
extremely thin small outline package; no leads;
8 terminals; body 1.2 1.0 0.35 mm
SOT1116
74AUP3G07GS
40 C to +125 C
XSON8
extremely thin small outline package; no leads;
8 terminals; body 1.35 1.0 0.35 mm
SOT1203
4. Marking
Table 2.
Marking codes
Type number
Marking code[1]
74AUP3G07DC
p07
74AUP3G07GT
p07
74AUP3G07GM
p07
74AUP3G07GN
p7
74AUP3G07GS
p7
[1]
The pin 1 indicator is located on the lower left corner of the device, below the marking code.
5. Functional diagram
$
<
$
<
$
<
$
<
<
$
<
$
$
<
*1'
DDD
Fig 1.
Logic symbol
74AUP3G07
Product data sheet
PQD
DDD
Fig 2.
IEC logic symbol
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 5 October 2016
Fig 3.
Logic diagram (one gate)
©
Nexperia B.V. 2017. All rights reserved
2 of 18
74AUP3G07
Nexperia
Low-power triple buffer with open-drain output
6. Pinning information
6.1 Pinning
$83*
$
9&&
<
<
$
$
*1'
<
$83*
$
9&&
<
<
$
$
*1'
<
DDD
7UDQVSDUHQWWRSYLHZ
DDD
Fig 4.
Pin configuration SOT765-1
Fig 5.
Pin configuration SOT833-1, SOT1116 and
SOT1203
$83*
<
$
<
9&&
WHUPLQDO
LQGH[DUHD
$
<
$
*1'
DDD
7UDQVSDUHQWWRSYLHZ
Fig 6.
Pin configuration SOT902-2
6.2 Pin description
Table 3.
Symbol
Pin description
Pin
Description
SOT765-1, SOT833-1, SOT1116 and SOT1203
SOT902-2
1A, 2A, 3A
1, 3, 6
7, 5, 2
data input
1Y, 2Y, 3Y
7, 5, 2
1, 3, 6
data output
GND
4
4
ground (0 V)
VCC
8
8
supply voltage
74AUP3G07
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 5 October 2016
©
Nexperia B.V. 2017. All rights reserved
3 of 18
74AUP3G07
Nexperia
Low-power triple buffer with open-drain output
7. Functional description
Table 4.
Function table[1]
Input nA
Output nY
L
L
H
Z
[1]
H = HIGH voltage level; L = LOW voltage level; Z = high-impedance OFF-state.
8. Limiting values
Table 5.
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol
Parameter
VCC
supply voltage
IIK
input clamping current
VI
input voltage
Conditions
Min
Max
Unit
0.5
+4.6
V
50
-
[1]
0.5
+4.6
50
-
[1]
0.5
+4.6
-
20
mA
50
mA
VI < 0 V
mA
V
IOK
output clamping current
VO < 0 V
VO
output voltage
Active mode and Power-down mode
IO
output current
VO = 0 V to VCC
ICC
supply current
-
IGND
ground current
50
-
mA
Tstg
storage temperature
65
+150
C
-
250
mW
total power dissipation
Ptot
[1]
[2]
Tamb = 40 C to +125 C
[2]
mA
V
The minimum input and output voltage ratings may be exceeded if the input and output current ratings are observed.
For VSSOP8 packages: above 110 C, the value of Ptot derates linearly with 8.0 mW/K.
For XSON8 and XQFN8 packages: above 118 C, the value of Ptot derates linearly with 7.8 mW/K.
9. Recommended operating conditions
Table 6.
Recommended operating conditions
Symbol
Parameter
VCC
supply voltage
VI
input voltage
VO
output voltage
Conditions
Active mode and Power-down mode
Tamb
ambient temperature
t/V
input transition rise and fall rate
74AUP3G07
Product data sheet
VCC = 0.8 V to 3.6 V
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 5 October 2016
Min
Max
Unit
0.8
3.6
V
0
3.6
V
0
3.6
V
40
+125
C
0
200
ns/V
©
Nexperia B.V. 2017. All rights reserved
4 of 18
74AUP3G07
Nexperia
Low-power triple buffer with open-drain output
10. Static characteristics
Table 7.
Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
Typ
Max
Unit
VCC = 0.8 V
0.70 VCC
-
-
V
VCC = 0.9 V to 1.95 V
0.65 VCC
-
-
V
VCC = 2.3 V to 2.7 V
1.6
-
-
V
VCC = 3.0 V to 3.6 V
2.0
-
-
V
VCC = 0.8 V
-
-
0.30 VCC V
VCC = 0.9 V to 1.95 V
-
-
0.35 VCC V
VCC = 2.3 V to 2.7 V
-
-
0.7
V
VCC = 3.0 V to 3.6 V
-
-
0.9
V
IO = 20 A; VCC = 0.8 V to 3.6 V
-
-
0.1
V
IO = 1.1 mA; VCC = 1.1 V
-
-
IO = 1.7 mA; VCC = 1.4 V
-
-
0.31
V
Tamb = 25 C
VIH
VIL
VOL
HIGH-level input voltage
LOW-level input voltage
LOW-level output voltage
VI = VIH or VIL
0.3 VCC V
IO = 1.9 mA; VCC = 1.65 V
-
-
0.31
V
IO = 2.3 mA; VCC = 2.3 V
-
-
0.31
V
IO = 3.1 mA; VCC = 2.3 V
-
-
0.44
V
IO = 2.7 mA; VCC = 3.0 V
-
-
0.31
V
IO = 4.0 mA; VCC = 3.0 V
-
-
0.44
V
II
input leakage current
VI = GND to 3.6 V; VCC = 0 V to 3.6 V
-
-
0.1
A
IOZ
OFF-state output current
VI = VIH; VO = 0 V to 3.6 V; VCC = 0 V
to 3.6 V
-
-
0.1
A
IOFF
power-off leakage current
VI or VO = 0 V to 3.6 V; VCC = 0 V
-
-
0.2
A
IOFF
additional power-off
leakage current
VI or VO = 0 V to 3.6 V;
VCC = 0 V to 0.2 V
-
-
0.2
A
ICC
supply current
VI = GND or VCC; IO = 0 A;
VCC = 0.8 V to 3.6 V
-
-
0.5
A
ICC
additional supply current
VI = VCC 0.6 V; IO = 0 A; VCC = 3.3 V
-
-
40
A
CI
input capacitance
VCC = 0 V to 3.6 V; VI = GND or VCC
-
0.7
-
pF
CO
output capacitance
VO = GND; VCC = 0 V
-
0.9
-
pF
VCC = 0.8 V
0.70 VCC
-
-
V
VCC = 0.9 V to 1.95 V
0.65 VCC
-
-
V
VCC = 2.3 V to 2.7 V
1.6
-
-
V
VCC = 3.0 V to 3.6 V
-
V
Tamb = 40 C to +85 C
VIH
VIL
HIGH-level input voltage
LOW-level input voltage
74AUP3G07
Product data sheet
2.0
-
VCC = 0.8 V
-
-
0.30 VCC V
VCC = 0.9 V to 1.95 V
-
-
0.35 VCC V
VCC = 2.3 V to 2.7 V
-
-
0.7
V
VCC = 3.0 V to 3.6 V
-
-
0.9
V
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 5 October 2016
©
Nexperia B.V. 2017. All rights reserved
5 of 18
74AUP3G07
Nexperia
Low-power triple buffer with open-drain output
Table 7.
Static characteristics …continued
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
VOL
VI = VIH or VIL
LOW-level output voltage
Min
Typ
Max
Unit
IO = 20 A; VCC = 0.8 V to 3.6 V
-
-
0.1
V
0.3 VCC V
IO = 1.1 mA; VCC = 1.1 V
-
-
IO = 1.7 mA; VCC = 1.4 V
-
-
0.37
V
IO = 1.9 mA; VCC = 1.65 V
-
-
0.35
V
IO = 2.3 mA; VCC = 2.3 V
-
-
0.33
V
IO = 3.1 mA; VCC = 2.3 V
-
-
0.45
V
IO = 2.7 mA; VCC = 3.0 V
-
-
0.33
V
IO = 4.0 mA; VCC = 3.0 V
-
-
0.45
V
II
input leakage current
VI = GND to 3.6 V; VCC = 0 V to 3.6 V
-
-
0.5
A
IOZ
OFF-state output current
VI = VIH; VO = 0 V to 3.6 V; VCC = 0 V
to 3.6 V
-
-
0.5
A
IOFF
power-off leakage current
VI or VO = 0 V to 3.6 V; VCC = 0 V
-
-
0.5
A
IOFF
additional power-off
leakage current
VI or VO = 0 V to 3.6 V;
VCC = 0 V to 0.2 V
-
-
0.6
A
ICC
supply current
VI = GND or VCC; IO = 0 A;
VCC = 0.8 V to 3.6 V
-
-
0.9
A
ICC
additional supply current
VI = VCC 0.6 V; IO = 0 A; VCC = 3.3 V
-
-
50
A
VCC = 0.8 V
0.75 VCC
-
-
V
VCC = 0.9 V to 1.95 V
0.70 VCC
-
-
V
VCC = 2.3 V to 2.7 V
1.6
-
-
V
VCC = 3.0 V to 3.6 V
-
V
Tamb = 40 C to +125 C
VIH
VIL
VOL
HIGH-level input voltage
LOW-level input voltage
LOW-level output voltage
2.0
-
VCC = 0.8 V
-
-
0.25 VCC V
VCC = 0.9 V to 1.95 V
-
-
0.30 VCC V
VCC = 2.3 V to 2.7 V
-
-
0.7
V
VCC = 3.0 V to 3.6 V
-
-
0.9
V
IO = 20 A; VCC = 0.8 V to 3.6 V
-
-
0.11
V
IO = 1.1 mA; VCC = 1.1 V
-
-
VI = VIH or VIL
0.33 VCC V
IO = 1.7 mA; VCC = 1.4 V
-
-
0.41
V
IO = 1.9 mA; VCC = 1.65 V
-
-
0.39
V
IO = 2.3 mA; VCC = 2.3 V
-
-
0.36
V
IO = 3.1 mA; VCC = 2.3 V
-
-
0.50
V
IO = 2.7 mA; VCC = 3.0 V
-
-
0.36
V
IO = 4.0 mA; VCC = 3.0 V
-
-
0.50
V
II
input leakage current
VI = GND to 3.6 V; VCC = 0 V to 3.6 V
-
-
0.75
A
IOZ
OFF-state output current
VI = VIH; VO = 0 V to 3.6 V; VCC = 0 V
to 3.6 V
-
-
0.75
A
IOFF
power-off leakage current
VI or VO = 0 V to 3.6 V; VCC = 0 V
-
-
0.75
A
74AUP3G07
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 5 October 2016
©
Nexperia B.V. 2017. All rights reserved
6 of 18
74AUP3G07
Nexperia
Low-power triple buffer with open-drain output
Table 7.
Static characteristics …continued
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
Typ
Max
Unit
IOFF
additional power-off
leakage current
VI or VO = 0 V to 3.6 V;
VCC = 0 V to 0.2 V
-
-
0.75
A
ICC
supply current
VI = GND or VCC; IO = 0 A;
VCC = 0.8 V to 3.6 V
-
-
1.4
A
ICC
additional supply current
VI = VCC 0.6 V; IO = 0 A; VCC = 3.3 V
-
-
75
A
11. Dynamic characteristics
Table 8.
Dynamic characteristics
Voltages are referenced to GND (ground = 0 V); for test circuit, see Figure 8.
Symbol Parameter
25 C
Conditions
Min
Typ[1]
40 C to +125 C
Max
Min
Max
(85 C)
Unit
Max
(125 C)
CL = 5 pF
tpd
propagation delay nA to nY; see Figure 7
[2]
-
11.6
-
-
-
-
ns
VCC = 1.1 V to 1.3 V
VCC = 0.8 V
2.1
4.1
7.5
1.7
9.1
10.0
ns
VCC = 1.4 V to 1.6 V
1.6
3.0
5.1
1.3
6.1
6.7
ns
VCC = 1.65 V to 1.95 V
1.6
2.7
4.0
1.2
5.0
5.5
ns
VCC = 2.3 V to 2.7 V
1.1
2.1
3.2
0.9
4.0
4.4
ns
VCC = 3.0 V to 3.6 V
1.4
2.2
2.8
1.1
3.3
3.6
ns
CL = 10 pF
tpd
propagation delay nA to nY; see Figure 7
[2]
-
14.7
-
-
-
-
ns
VCC = 1.1 V to 1.3 V
VCC = 0.8 V
3.0
5.1
9.0
2.4
11.2
12.3
ns
VCC = 1.4 V to 1.6 V
2.3
3.8
6.1
2.0
7.4
8.1
ns
VCC = 1.65 V to 1.95 V
2.4
3.6
4.8
1.8
6.1
6.7
ns
VCC = 2.3 V to 2.7 V
1.7
2.8
3.8
1.3
4.8
5.3
ns
VCC = 3.0 V to 3.6 V
2.2
3.1
4.2
1.6
4.5
5.0
ns
CL = 15 pF
tpd
propagation delay nA to nY; see Figure 7
VCC = 0.8 V
74AUP3G07
Product data sheet
[2]
-
17.7
-
-
-
-
ns
VCC = 1.1 V to 1.3 V
3.5
6.1
10.4
3.2
13.1
14.5
ns
VCC = 1.4 V to 1.6 V
3.0
4.5
6.8
2.6
8.6
9.4
ns
VCC = 1.65 V to 1.95 V
2.8
4.4
6.7
2.2
7.8
8.6
ns
VCC = 2.3 V to 2.7 V
2.4
3.4
4.5
1.9
5.3
5.8
ns
VCC = 3.0 V to 3.6 V
2.2
4.0
5.7
1.9
6.1
6.7
ns
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 5 October 2016
©
Nexperia B.V. 2017. All rights reserved
7 of 18
74AUP3G07
Nexperia
Low-power triple buffer with open-drain output
Table 8.
Dynamic characteristics …continued
Voltages are referenced to GND (ground = 0 V); for test circuit, see Figure 8.
Symbol Parameter
25 C
Conditions
40 C to +125 C
Unit
Min
Typ[1]
Max
Min
Max
(85 C)
Max
(125 C)
-
26.7
-
-
-
-
ns
VCC = 1.1 V to 1.3 V
4.8
9.0
15.6
4.3
18.8
20.7
ns
CL = 30 pF
propagation delay nA to nY; see Figure 7
tpd
[2]
VCC = 0.8 V
VCC = 1.4 V to 1.6 V
4.1
6.7
9.4
3.7
11.8
13.0
ns
VCC = 1.65 V to 1.95 V
3.8
6.8
9.7
3.2
11.0
12.1
ns
VCC = 2.3 V to 2.7 V
3.7
5.2
6.7
3.0
7.1
7.8
ns
VCC = 3.0 V to 3.6 V
3.6
6.4
9.7
2.8
10.4
11.4
ns
VCC = 0.8 V
-
0.5
-
-
-
-
pF
VCC = 1.1 V to 1.3 V
-
0.6
-
-
-
-
pF
VCC = 1.4 V to 1.6 V
-
0.6
-
-
-
-
pF
VCC = 1.65 V to 1.95 V
-
0.7
-
-
-
-
pF
VCC = 2.3 V to 2.7 V
-
0.9
-
-
-
-
pF
VCC = 3.0 V to 3.6 V
-
1.2
-
-
-
-
pF
CL = 5 pF, 10 pF, 15 pF and 30 pF
power dissipation
capacitance
CPD
fi = 1 MHz; VI = GND to VCC
[3][4]
[1]
All typical values are measured at nominal VCC.
[2]
tpd is the same as tPZL and tPLZ.
[3]
All specified values are the average typical values over all stated loads.
[4]
CPD is used to determine the dynamic power dissipation (PD in W).
PD = CPD VCC2 fi N where:
fi = input frequency in MHz;
VCC = supply voltage in V;
N = number of inputs switching.
74AUP3G07
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 5 October 2016
©
Nexperia B.V. 2017. All rights reserved
8 of 18
74AUP3G07
Nexperia
Low-power triple buffer with open-drain output
12. Waveforms
9,
90
Q$LQSXW
90
*1'
W 3=/
W 3/=
9&&
Q
很抱歉,暂时无法提供与“74AUP3G07GNX”相匹配的价格&库存,您可以联系我们找货
免费人工找货