HEF4069UB
Hex unbuffered inverter
Rev. 9 — 16 December 2015
Product data sheet
1. General description
The HEF4069UB is a general purpose hex unbuffered inverter. Each inverter has a single
stage.
It operates over a recommended VDD power supply range of 3 V to 15 V referenced to VSS
(usually ground). Unused inputs must be connected to VDD, VSS, or another input.
2. Features and benefits
Fully static operation
5 V, 10 V, and 15 V parametric ratings
Standardized symmetrical output characteristics
Specified from 40 C to +85 C and 40 C to +125 C
Complies with JEDEC standard JESD 13-B
3. Applications
Oscillator
4. Ordering information
Table 1.
Ordering information
All types operate from 40 C to +125 C.
Type number
Package
Name
Description
Version
HEF4069UBT
SO14
plastic small outline package; 14 leads; body width 3.9 mm
SOT108-1
HEF4069UBTT
TSSOP14
plastic thin shrink small outline package; 14 leads; body width 4.4 mm
SOT402-1
HEF4069UB
Nexperia
Hex unbuffered inverter
5. Functional diagram
$
$
$
$
$
$
<
<
<
<
9''
<
$
<
<
966
DDJ
Fig 1.
DDJ
Functional diagram
Fig 2.
Schematic diagram (one inverter)
6. Pinning information
6.1 Pinning
$
9''
<
$
$
<
<
+()8% $
$
<
<
$
966
<
DDJ
Fig 3.
Pin configuration
6.2 Pin description
Table 2.
Pin description
Symbol
Pin
Description
1A to 6A
1, 3, 5, 9, 11, 13
input
1Y to 6Y
2, 4, 6, 8, 10, 12
output
VSS
7
ground (0 V)
VDD
14
supply voltage
HEF4069UB
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 9 — 16 December 2015
©
Nexperia B.V. 2017. All rights reserved
2 of 16
HEF4069UB
Nexperia
Hex unbuffered inverter
7. Limiting values
Table 3.
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol
Parameter
VDD
supply voltage
Conditions
VI < 0.5 V or VI > VDD + 0.5 V
Min
Max
Unit
0.5
+18
V
mA
-
10
0.5
VDD + 0.5
-
10
mA
-
10
mA
50
mA
IIK
input clamping current
VI
input voltage
IOK
output clamping current
II/O
input/output current
IDD
supply current
Tstg
storage temperature
65
+150
C
Tamb
ambient temperature
40
+125
C
Ptot
total power dissipation
P
power dissipation
VO < 0.5 V or VO > VDD + 0.5 V
-
V
Tamb = 40 C to +125 C
SO14
[1]
-
500
mW
TSSOP14
[2]
-
500
mW
-
100
mW
per output
[1]
For SO14 packages: above Tamb = 70 C, Ptot derates linearly with 8 mW/K.
[2]
For TSSOP14 packages: above Tamb = 60 C, Ptot derates linearly with 5.5 mW/K.
8. Recommended operating conditions
Table 4.
Recommended operating conditions
Symbol
Parameter
Min
Typ
Max
VDD
supply voltage
3
-
15
V
VI
input voltage
0
-
VDD
V
Tamb
ambient temperature
40
-
+125
C
HEF4069UB
Product data sheet
Conditions
in free air
All information provided in this document is subject to legal disclaimers.
Rev. 9 — 16 December 2015
©
Unit
Nexperia B.V. 2017. All rights reserved
3 of 16
HEF4069UB
Nexperia
Hex unbuffered inverter
9. Static characteristics
Table 5.
Static characteristics
VSS = 0 V; VI = VSS or VDD; unless otherwise specified.
Symbol Parameter
VIH
VIL
VOH
VOL
IOH
IOL
Conditions
VDD
Tamb = 40 C
Tamb = +25 C
Tamb = +85 C Tamb = +125 C Unit
Min
Max
Min
Max
Min
Max
Min
Max
5V
4
-
4
-
4
-
4
-
V
10 V
8
-
8
-
8
-
8
-
V
15 V
12.5
-
12.5
-
12.5
-
12.5
-
V
5V
-
1
-
1
-
1
-
1
V
10 V
-
2
-
2
-
2
-
2
V
15 V
-
2.5
-
2.5
-
2.5
-
2.5
V
HIGH-level
IO < 1 A
output voltage
5V
4.95
-
4.95
-
4.95
-
4.95
-
V
10 V
9.95
-
9.95
-
9.95
-
9.95
-
V
15 V
14.95
-
14.95
-
14.95
-
14.95
-
V
LOW-level
IO < 1 A
output voltage
5V
-
0.05
-
0.05
-
0.05
-
0.05
V
10 V
-
0.05
-
0.05
-
0.05
-
0.05
V
15 V
-
0.05
-
0.05
-
0.05
-
0.05
V
5V
-
1.7
-
1.4
-
1.1
-
1.1
mA
5V
-
0.64
-
0.5
-
0.36
-
0.36 mA
VO = 9.5 V
10 V
-
1.6
-
1.3
-
0.9
-
0.9
mA
VO = 13.5 V
15 V
-
4.2
-
3.4
-
2.4
-
2.4
mA
5V
0.64
-
0.5
-
0.36
-
0.36
-
mA
10 V
1.6
-
1.3
-
0.9
-
0.9
-
mA
15 V
4.2
-
3.4
-
2.4
-
2.4
-
mA
HIGH-level
input voltage
LOW-level
input voltage
IO < 1 A
IO < 1 A
HIGH-level
VO = 2.5 V
output current V = 4.6 V
O
LOW-level
VO = 0.4 V
output current V = 0.5 V
O
VO = 1.5 V
II
input leakage
current
15 V
-
0.1
-
0.1
-
1.0
-
1.0
A
IDD
supply current all valid input 5 V
combinations; 10 V
IO = 0 A
15 V
-
0.25
-
0.25
-
7.5
-
7.5
A
-
0.5
-
0.5
-
15.0
-
15.0
A
-
1.0
-
1.0
-
30.0
-
30.0
A
-
-
-
7.5
-
-
-
-
pF
CI
input
capacitance
HEF4069UB
Product data sheet
digital inputs
All information provided in this document is subject to legal disclaimers.
Rev. 9 — 16 December 2015
©
Nexperia B.V. 2017. All rights reserved
4 of 16
HEF4069UB
Nexperia
Hex unbuffered inverter
10. Dynamic characteristics
Table 6.
Dynamic characteristics
Tamb = 25 C; for waveforms see Figure 4; for test circuit see Figure 5.
Symbol Parameter
HIGH to LOW
propagation delay
tPHL
tPLH
tTHL
[1]
VDD
Extrapolation formula[1]
nA to nY;
5V
LOW to HIGH
propagation delay
nA to nY
HIGH to LOW output
transition time
output nY
LOW to HIGH output
transition time
tTLH
Conditions
output nY
Min
Typ
Max
Unit
18 ns + (0.55 ns/pF)CL
-
45
90
ns
10 V
9 ns + (0.23 ns/pF)CL
-
20
40
ns
15 V
7 ns + (0.16 ns/pF)CL
-
15
25
ns
5V
13 ns + (0.55 ns/pF)CL
-
40
80
ns
10 V
9 ns + (0.23 ns/pF)CL
-
20
40
ns
15 V
7 ns + (0.16 ns/pF)CL
-
15
30
ns
5V
10 ns + (1.00 ns/pF)CL
-
60
120
ns
10 V
9 ns + (0.42 ns/pF)CL
-
30
60
ns
15 V
6 ns + (0.28 ns/pF)CL
-
20
40
ns
5V
10 ns + (1.00 ns/pF)CL
-
60
120
ns
10 V
9 ns + (0.42 ns/pF)CL
-
30
60
ns
15 V
6 ns + (0.28 ns/pF)CL
-
20
40
ns
The typical value of the propagation delay and output transition time can be calculated with the extrapolation formula (CL in pF).
Table 7.
Dynamic power dissipation
VSS = 0 V; tr = tf 20 ns; Tamb = 25 C.
Symbol Parameter
PD
dynamic power dissipation
VDD
Typical formula
Where
5V
PD = 600 fi + (fo CL) VDD (W)
2
10 V PD = 4000 fi + (fo CL) VDD2 (W)
fi = input frequency in MHz;
fo = output frequency in MHz;
15 V PD = 22000 fi + (fo CL) VDD (W) CL = output load capacitance in pF;
(fo CL) = sum of the outputs;
2
VDD = supply voltage in V.
HEF4069UB
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 9 — 16 December 2015
©
Nexperia B.V. 2017. All rights reserved
5 of 16
HEF4069UB
Nexperia
Hex unbuffered inverter
11. Waveforms
WU
9,
90
LQSXW
9
WI
W3+/
92+
W3/+
90
RXWSXW
92/
W7+/
W7/+
DDJ
Measurement points: VM = 0.5VDD.
Logic levels: VOL and VOH are typical output voltage levels that occur with the output load.
Fig 4.
Propagation delay and transition times
9''
*
9,
92
'87
&/
57
DDJ
Definitions for test circuit:
CL = load capacitance including jig and probe capacitance;
RT = termination resistance should be equal to the output impedance Zo of the pulse generator;
For test data refer to Table 8.
Fig 5.
Test circuit for measuring switching times
Table 8.
Test data
Supply voltage
Input
VDD
VI
tr, tf
CL
5 V to 15 V
VSS or VDD
20 ns
50 pF
HEF4069UB
Product data sheet
Load
All information provided in this document is subject to legal disclaimers.
Rev. 9 — 16 December 2015
©
Nexperia B.V. 2017. All rights reserved
6 of 16
HEF4069UB
Nexperia
Hex unbuffered inverter
11.1 Transfer characteristics
DDJ
92
9
,'
P$
92
9
,'
$
DDJ
9,9
9,9
a. VDD = 5 V; IO = 0 A
b. VDD = 10 V; IO = 0 A
DDJ
92
9
,'
P$
9,9
c. VDD = 15 V; IO = 0 A
(1) VO = output voltage.
(2) ID = drain current.
Fig 6.
Typical transfer characteristics
HEF4069UB
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 9 — 16 December 2015
©
Nexperia B.V. 2017. All rights reserved
7 of 16
HEF4069UB
Nexperia
Hex unbuffered inverter
12. Application information
Some examples of applications for the HEF4069UB.
Figure 7 shows an astable relaxation oscillator using two HEF4069UB inverters and 2
BAW62 diodes. The oscillation frequency is mainly determined by R1 C1, provided
R1
很抱歉,暂时无法提供与“HEF4069UBTT,118”相匹配的价格&库存,您可以联系我们找货
免费人工找货