VRM = 400 V, IF(AV) = 10 A, trr = 25 ns
Fast Recovery Diode
FMXA-1104S
Description
The FMXA-1104S is a fast recovery diode of 400 V /
10 A. The maximum trr of 25 ns is realized by
optimizing a life-time control.
Data Sheet
Package
TO220F-2L
Features
●
●
●
●
●
●
VRM ------------------------------------------------------ 400 V
IF(AV) ------------------------------------------------------- 10 A
VF --------------------------------------------------------1.50 V
trr ---------------------------------------------------------- 25 ns
Bare Lead Frame: Pb-free (RoHS Compliant)
Flammability: Equivalent to UL94V-0
Applications
● Secondary-side Rectifier Diode
(Flyback Converter, LLC Converter, etc.)
● Freewheel Diode
(Offline Buck Converter, Offline Buck-boost
Converter, etc.)
FMXA-1104S-DSE Rev.1.0
SANKEN ELECTRIC CO., LTD.
Dec. 12, 2019
https://www.sanken-ele.co.jp/en
© SANKEN ELECTRIC CO., LTD. 2019
(1)
(1)
(2)
(2)
(1) Cathode
(2) Anode
Not to scale
1
FMXA-1104S
Absolute Maximum Ratings
Unless otherwise specified, TA = 25 °C.
Parameter
Symbol
Conditions
Rating
Unit
Nonrepetitive Peak Reverse Voltage
VRSM
400
V
Repetitive Peak Reverse Voltage
VRM
400
V
Average Forward Current
IF(AV)
10
A
Surge Forward Current
IFSM
100
A
50
A2s
See Figure 1 and Figure 2
Half cycle sine wave, positive
side, 10 ms, 1 shot
1 ms ≤ t ≤ 10 ms
I2t Limiting Value
I2t
Junction Temperature
TJ
−40 to 150
°C
Storage Temperature
TSTG
−40 to 150
°C
Electrical Characteristics
Unless otherwise specified, TA = 25 °C.
Parameter
Symbol
Forward Voltage Drop
VF
Reverse Leakage Current
Reverse Leakage Current
under High Temperature
IR
H∙IR
Reverse Recovery Time
trr
Thermal Resistance(1)
Conditions
Min.
Typ.
Max.
Unit
TJ = 25 °C, IF = 10 A
—
—
1.50
V
TJ = 100 °C, IF = 10 A
—
1.16
—
V
VR = VRM
—
—
100
µA
VR = VRM, TJ = 150 °C
—
—
30
mA
IF = IRP = 500 mA,
90% recovery point,
TJ = 25 °C
—
—
25
ns
—
—
4.0
°C/W
Min.
Typ.
Max.
Unit
0.490
—
0.686
N∙m
Rth(J-C)
Mechanical Characteristics
Parameter
Conditions
Heatsink Mounting Screw Torque
(1)
Rth (J-C) is thermal resistance between junction and the case. The case temperature is measured at the back side near the
screw hole.
FMXA-1104S-DSE Rev.1.0
SANKEN ELECTRIC CO., LTD.
Dec. 12, 2019
https://www.sanken-ele.co.jp/en
© SANKEN ELECTRIC CO., LTD. 2019
2
FMXA-1104S
Rating and Characteristic Curves
10
10
8
Average Forward Current, IF(AV) (A)
Average Forward Current, IF(AV) (A)
DC
t/T = 1/2
6
t/T = 1/3, sine wave
t/T = 1/6
4
TJ = 150 °C
2
DC
8
Sine wave
6
t/T = 1/2
t/T = 1/3
4
t/T = 1/6
TJ = 150 °C
2
t
t
T
T
0
0
50
70
90
110
130
0
150
100
150
Case Temperature, TC (°C)
Case Temperature, TC (°C)
Figure 1.
50
Typical Characteristics: IF(AV) vs. TC
(VR = 0 V)
Figure 2.
100
Typical Characteristics: IF(AV) vs. TC
(VR = 400 V)
1.E-02
Reverse Leakage Current, IR (A)
TJ = 150 °C
Forward Current, IF (A)
10
TJ = 100 °C
1
TJ = 25 °C
0.1
0.01
0.001
TJ = 150 °C
1.E-03
TJ = 100 °C
1.E-04
1.E-05
1.E-06
TJ = 25 °C
1.E-07
0
0.4
0.8
1.2
1.6
2
2.4
2.8
0
Forward Voltage Drop, VF (V)
Figure 3.
Typical Characteristics: VF vs. IF
100
200
300
400
Reverse Voltage, VR (V)
Figure 4.
FMXA-1104S-DSE Rev.1.0
SANKEN ELECTRIC CO., LTD.
Dec. 12, 2019
https://www.sanken-ele.co.jp/en
© SANKEN ELECTRIC CO., LTD. 2019
Typical Characteristics: VR vs. IR
3
FMXA-1104S
Physical Dimensions
● TO220F-2L
4.7 ± 0.1
10.1 ± 0.2
2.54 ± 0.1
3.3 ± 0.2
3.2 ± 0.2
19.10 ± 0.3
3.0 (min.)
15.8 ± 0.3
9.20 ± 0.2
1.35 ± 0.2
13.55 ± 0.3
2.54 ± 0.1
(Roots of pins)
0.8 ± 0.1
2.54 ± 0.1
2.45 ± 0.2
(Root of pin)
0.6 ± 0.1
(Roots of pins)
NOTES:
-
Dimensions in millimeters
All the dimensions exclude mold flashes.
Bare lead frame: Pb-free (RoHS compliant)
When soldering the products, it is required to minimize the working time within the following limits:
Flow: 260 ± 5 °C / 10 ± 1 s, 2 times
Soldering Iron: 380 ± 10 °C / 3.5 ± 0.5 s, 1 time
Soldering should be at a distance of at least 1.5 mm from the body of the product.
FMXA-1104S-DSE Rev.1.0
SANKEN ELECTRIC CO., LTD.
Dec. 12, 2019
https://www.sanken-ele.co.jp/en
© SANKEN ELECTRIC CO., LTD. 2019
4
FMXA-1104S
Marking Diagram
XA 11 04
S
Specific Device Code (See Table 1)
YMDDXX
Lot Number:
Y is the last digit of the year of manufacture (0 to 9)
M is the month of the year (1 to 9, O, N, or D)
DD is the day of the month (01 to 31)
XX is the control number
1
2
Table 1. Specific Device Code
Specific Device Code
Part Number
XA1104S
FMXA-1104S
FMXA-1104S-DSE Rev.1.0
SANKEN ELECTRIC CO., LTD.
Dec. 12, 2019
https://www.sanken-ele.co.jp/en
© SANKEN ELECTRIC CO., LTD. 2019
5
FMXA-1104S
Important Notes
● All data, illustrations, graphs, tables and any other information included in this document (the “Information”) as to Sanken’s
products listed herein (the “Sanken Products”) are current as of the date this document is issued. The Information is subject to any
change without notice due to improvement of the Sanken Products, etc. Please make sure to confirm with a Sanken sales
representative that the contents set forth in this document reflect the latest revisions before use.
● The Sanken Products are intended for use as components of general purpose electronic equipment or apparatus (such as home
appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the Sanken Products,
please put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to
Sanken. When considering use of the Sanken Products for any applications that require higher reliability (such as transportation
equipment and its control systems, traffic signal control systems or equipment, disaster/crime alarm systems, various safety
devices, etc.), you must contact a Sanken sales representative to discuss the suitability of such use and put your signature, or affix
your name and seal, on the specification documents of the Sanken Products and return them to Sanken, prior to the use of the
Sanken Products. The Sanken Products are not intended for use in any applications that require extremely high reliability such as:
aerospace equipment; nuclear power control systems; and medical equipment or systems, whose failure or malfunction may result
in death or serious injury to people, i.e., medical devices in Class III or a higher class as defined by relevant laws of Japan
(collectively, the “Specific Applications”). Sanken assumes no liability or responsibility whatsoever for any and all damages and
losses that may be suffered by you, users or any third party, resulting from the use of the Sanken Products in the Specific
Applications or in manner not in compliance with the instructions set forth herein.
● In the event of using the Sanken Products by either (i) combining other products or materials or both therewith or (ii) physically,
chemically or otherwise processing or treating or both the same, you must duly consider all possible risks that may result from all
such uses in advance and proceed therewith at your own responsibility.
● Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the
occurrence of any failure or defect or both in semiconductor products at a certain rate. You must take, at your own responsibility,
preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which
the Sanken Products are used, upon due consideration of a failure occurrence rate and derating, etc., in order not to cause any
human injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products.
Please refer to the relevant specification documents and Sanken’s official website in relation to derating.
● No anti-radioactive ray design has been adopted for the Sanken Products.
● The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples, all
information and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of
use of the Sanken Products.
● Sanken assumes no responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third
party, or any possible infringement of any and all property rights including intellectual property rights and any other rights of you,
users or any third party, resulting from the Information.
● No information in this document can be transcribed or copied or both without Sanken’s prior written consent.
● Regarding the Information, no license, express, implied or otherwise, is granted hereby under any intellectual property rights and
any other rights of Sanken.
● Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied,
including, without limitation, any warranty (i) as to the quality or performance of the Sanken Products (such as implied warranty
of merchantability, and implied warranty of fitness for a particular purpose or special environment), (ii) that any Sanken Product is
delivered free of claims of third parties by way of infringement or the like, (iii) that may arise from course of performance, course
of dealing or usage of trade, and (iv) as to the Information (including its accuracy, usefulness, and reliability).
● In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and
regulations that regulate the inclusion or use or both of any particular controlled substances, including, but not limited to, the EU
RoHS Directive, so as to be in strict compliance with such applicable laws and regulations.
● You must not use the Sanken Products or the Information for the purpose of any military applications or use, including but not
limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Information, or
providing them for non-residents, you must comply with all applicable export control laws and regulations in each country
including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan, and
follow the procedures required by such applicable laws and regulations.
● Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including
the falling thereof, out of Sanken’s distribution network.
● Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is
error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting
from any possible errors or omissions in connection with the Information.
● Please refer to our official website in relation to general instructions and directions for using the Sanken Products, and refer to the
relevant specification documents in relation to particular precautions when using the Sanken Products.
● All rights and title in and to any specific trademark or tradename belong to Sanken and such original right holder(s).
DSGN-CEZ-16003
FMXA-1104S-DSE Rev.1.0
SANKEN ELECTRIC CO., LTD.
Dec. 12, 2019
https://www.sanken-ele.co.jp/en
© SANKEN ELECTRIC CO., LTD. 2019
6