MPL-1036S

MPL-1036S

  • 厂商:

    SANKEN(三垦)

  • 封装:

    TO263

  • 描述:

    DIODEUF600V3ATO-263

  • 数据手册
  • 价格&库存
MPL-1036S 数据手册
Ultrafast Recovery Diode MPL-1036S General Description A surface mount device added to 600V_L series. Realizes better space-saving in mounting on a printed circuit board by using a surface mount package (TO-263). January, 2006 Package --- TO-263 Applications ● Continuous-current-mode PFC circuit. ● An output rectifier for SMPS, UPS, or DC-DC converters. ● A Flywheel diode for inverters and choppers. Features ● Surface mount package (TO-263) ● Low loss FRD (600 V_L series) Key Specifications Absolute maximum ratings Parameter Symbol VRSM VRM IF(AV) IFSM Unit V V A A Rating 600 600 3 50 Die Structure: Silicon Planer Diode (FRD) Transient Peak Reverse Voltage Peak Reverse Voltage Average Forward Current Peak Surge Forward Current Electrical characteristics Parameter Forward Voltage Drop Reverse Leakage Current Reverse Leakage Current Under High Temperature Reverse Recovery Time Symbol Unit VF IR H•IR trr V μA μA ns Rating Conditions 1.75 max. IF=3A 50 max. 100 max. 50 max. VR=VRM VR=VRM, Tj=150°C IF=IRP=100mA 90%Recovery point Sanken Electric Co.,Ltd. 1/5 D01-007JE-060113 Ultrafast Recovery Diode MPL-1036S §1. Absolute Maximum Ratings and Electrical Characteristics •Absolute Maximum Ratings No. 1 2 3 4 5 6 7 Parameter Transient Peak Reverse Voltage Peak Reverse Voltage Average Forward Current Peak Surge Forward Current I2t Limiting Value Junction Temperature Storage Temperature Symbol Unit Rating January, 2006 Conditions VRSM VRM IF(AV) IFSM 2 V V A A A2S °C °C 600 600 3 50 12.5 -40 to +150 -40 to+150 10msec. Half sine-wave, one shot 1msec ≤ t ≤ 10msec It Tj Tstg • Electrical Characteristics No. 1 2 3 4 5 Parameter Symbol Unit Rating Conditions Forward Voltage Drop Reverse Leakage Current Reverse Leakage Current Under High Temperature Reverse Recovery Time Thermal Resistance VF IR H•IR trr Rth(j-c) V µA µA ns °C/W 1.75 max. 50 max. 100 max. 50 max 2.5 max. IF=3A VR=VRM VR=VRM, Tj=150°C IF=IRP=100mA 90% Recovery point Between Junction and case Sanken Electric Co.,Ltd. 2/5 D01-007JE-060113 Ultrafast Recovery Diode MPL-1036S §2. Package information 2-1 Package type, physical dimensions January, 2006 (3) (2) (1) (2) is connected to a heat sink. Unit: ㎜ 2-2 Marking Marking Part Number Type Name Polarity Lot number 1st letter: Last digit of year 2nd letter: Month From 1 to 9 for Jan. to Sep., O for Oct., N for Nov., D for Dec. 3rd letter: Day Week(Every month of 1st to 5th week) 4th to 6th letter: Suffix No. MPL-1036S L1036 Sanken Electric Co.,Ltd. 3/5 D01-007JE-060113 Ultrafast Recovery Diode MPL-1036S §3. Characteristics IF(AV) - PF 10 Forward Power Dissipation PF (W) Tj=150°C January, 2006 8 t T t/T=1/6 t/T=1/3,Sine-wave 6 4 t/T=1/2 DC 2 0 0 1 2 Average Forward Current IF(AV) (A) 3 §4. Derating 3 Tc - IF(AV) VR=0 (V) DC IF(AV) (A) t/T=1/3, Sine-wave t/T=1/2 Average Forward Current 2 t/T=1/6 1 Tj=150°C t T 0 0 50 100 Case Temperature Tc (°C) 150 Sanken Electric Co.,Ltd. 4/5 D01-007JE-060113 Ultrafast Recovery Diode MPL-1036S CAUTION / WARNING January, 2006 ●The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. ● Sanken reserves the right to make changes without further notice to any products herein in the interest of improvements in the performance, reliability, or manufacturability of its products. Before placing an order, Sanken advises its customers to obtain the latest version of the relevant information to verify that the information being relied upon is current. ● Application and operation examples described in this catalog are quoted for the sole purpose of reference for the use of the products herein and Sanken can assume no responsibility for any infringement of industrial property rights, intellectual property rights or any other rights of Sanken or any third party which may result from its use. ● When using the products herein, the applicability and suitability of such products for the intended purpose or object shall be reviewed at the users’ responsibility. ● Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure nd defect of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at their own risk, preventative measures including safety design of the equipment or systems against any possible injury, death, fires or damages to the society due to device failure or malfunction. ● Sanken products listed in this catalog are designed and intended for the use as components in general purpose electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Before placing an order, the user’s written consent to the specifications is requested. When considering the use of Sanken products in the applications where higher reliability is required (transportation equipment and its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various safety devices, etc.), please contact your nearest Sanken sales representative to discuss and obtain written confirmation of your specifications. The use of Sanken products without the written consent of Sanken in the applications where extremely high reliability is required (aerospace equipment, nuclear power control systems, life support systems, etc.) is strictly prohibited. ● Anti radioactive ray design is not considered for the products listed herein. ● This publication shall not be reproduced in whole or in part without prior written approval from Sanken. ●This is notification that you, as purchaser of the products/technology, are not allowed to perform any of the following: 1. Resell or retransfer these products/technology to any party intending to disturb international peace and security. 2. Use these products/technology yourself for activities disturbing international peace and security. 3. Allow any other party to use these products/technology for activities disturbing international peace and security. Also, as purchaser of these products/technology, you agree to follow the procedures for the export or transfer of these products/technology, under the Foreign Exchange and Foreign Trade Law, when you export or transfer the products/technology abroad. Sanken Electric Co.,Ltd. 5/5 D01-007JE-060113
MPL-1036S 价格&库存

很抱歉,暂时无法提供与“MPL-1036S”相匹配的价格&库存,您可以联系我们找货

免费人工找货
MPL-1036S
    •  国内价格 香港价格
    • 1+2.954001+0.36652
    • 10+2.8750210+0.35672
    • 50+2.8197350+0.34986
    • 100+2.76444100+0.34300
    • 500+2.75654500+0.34202
    • 1000+2.748651000+0.34104
    • 2000+2.740752000+0.34006
    • 4000+2.740754000+0.34006

    库存:960

    MPL-1036S
      •  国内价格
      • 1+5.64501
      • 10+4.46469
      • 50+4.25941
      • 100+3.11331
      • 200+1.62508
      • 500+0.71589

      库存:980