For Non-Isolated Off-Line PWM Controllers with Integrated Power MOSFET STR5A464x Series Data Sheet Description The STR5A464x Series is power ICs for switching power supplies, incorporating a MOSFET and a current mode PWM controller IC for non-isolated Buck converter and Inverting converter topologies. The operation mode is automatically changed, in response to load, to the fixed switching frequency, to the switching frequency control, and to the burst oscillation mode. Thus the power efficiency is improved. The product achieves high cost-performance power supply systems with few external components. Package DIP8 FB 1 8 S/GND VCC 2 7 S/GND 6 S/GND 5 S/GND D/ST 4 SOIC8 Features ● ● ● ● ● ● ● ● ● ● ● ● Pb-free (RoHS compliant) Buck Converter Inverting Converter Current Mode PWM Control Automatically Switch the Operation Mode According to the Load Heavy Load: 60 kHz (typ.) Fixed Switching Frequency Mode Medium Load: Green Mode, 23 kHz (typ.) to 60 kHz (typ.) Light Load: Burst Oscillation Mode No Current Detection Resistor Required (Built-in Current Sensing MOSFET) Built-in Startup Function Built-in Error Amplifier Random Switching Function Leading Edge Blanking Function Soft Start Function Protections Overload Protection (OLP): Auto-restart Overvoltage Protection (OVP): Auto-restart Thermal Shutdown with Hysteresis (TSD): Auto-restart R3 R1 U1 D1 VCC S/GND FB S/GND 1 S/GND FR1 DR1 L1 D/ST C3 C4 VOUT 6 L2 (+) 5 STR5A464S VAC C1 C2 S/GND FB 2 7 S/GND 6 S/GND 5 S/GND D/ST 4 Not to scale Selection Guide ● Electrical Characteristics fOSC(AVG) = 60 kHz (typ.) VD/ST = 700V (max.) Part Number STR5A464D STR5A464S RDS(ON) (max.) IDLIM (typ.) 13.6 Ω 0.41 A Package DIP8 SOIC8 Recommended Operating Condition Buck Inverting Converter Converter AC 85 V to AC 265 V Applications D2 S/GND 4 8 8 7 2 1 Input Voltage D/ST Input ≥ 40 V Voltage Output Voltage > 11 V > – 27.5 V Range* < 27.5 V < – 11 V *Add a zener diode or a regulator to VCC pin when target output voltage is high. Typical Application (Buck Convertor, STR5A464S) R2 VCC D3 C5 R4 (-) ● White Goods ● Auxiliary Power Supply (lighting Equipment with Microcomputer, etc.) ● Power Supply for Motor Control (actuator, etc.) ● Telecommunication Equipment (Convertible from 48 VDC to 15 VDC) ● Other SMPS STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 1 STR5A464x Series Contents Description ------------------------------------------------------------------------------------------------------ 1 Contents --------------------------------------------------------------------------------------------------------- 2 1. Absolute Maximum Ratings----------------------------------------------------------------------------- 3 2. Electrical Characteristics -------------------------------------------------------------------------------- 4 3. Mechanical Characteristics ----------------------------------------------------------------------------- 5 4. Performance Curves -------------------------------------------------------------------------------------- 5 5. Block Diagram --------------------------------------------------------------------------------------------- 6 6. Pin Configuration Definitions--------------------------------------------------------------------------- 6 7. Typical Application --------------------------------------------------------------------------------------- 7 8. Physical Dimensions -------------------------------------------------------------------------------------- 8 9. Marking Diagram --------------------------------------------------------------------------------------- 10 10. Operational Description ------------------------------------------------------------------------------- 11 10.1 Startup Operation of IC ------------------------------------------------------------------------- 11 10.2 Undervoltage Lockout (UVLO) ---------------------------------------------------------------- 11 10.3 Power Supply Startup and Soft Start Function --------------------------------------------- 11 10.4 Constant Voltage (CV) Control----------------------------------------------------------------- 12 10.4.1 Buck Converter Operation ---------------------------------------------------------------- 13 10.4.2 Inverting Converter Operation ----------------------------------------------------------- 13 10.5 Leading Edge Blanking Function -------------------------------------------------------------- 14 10.6 Random Switching Function -------------------------------------------------------------------- 14 10.7 Operation Mode ----------------------------------------------------------------------------------- 14 10.8 Overload Protection (OLP)---------------------------------------------------------------------- 15 10.9 Overvoltage Protection (OVP) ------------------------------------------------------------------ 15 10.10 Thermal Shutdown (TSD) ----------------------------------------------------------------------- 15 11. Design Notes ---------------------------------------------------------------------------------------------- 16 11.1 External Components ---------------------------------------------------------------------------- 16 11.1.1 Input and Output Electrolytic Capacitor ----------------------------------------------- 16 11.1.2 Inductor --------------------------------------------------------------------------------------- 16 11.1.3 VCC Pin Peripheral Circuit --------------------------------------------------------------- 16 11.1.4 FB Pin Peripheral Circuit ----------------------------------------------------------------- 16 11.1.5 Freewheeling Diode ------------------------------------------------------------------------- 17 11.1.6 Bleeder Resistance -------------------------------------------------------------------------- 17 11.2 D/ST Pin--------------------------------------------------------------------------------------------- 17 11.3 PCB Trace Layout -------------------------------------------------------------------------------- 17 12. Pattern Layout Example (Buck Converter) -------------------------------------------------------- 19 13. Design Example ------------------------------------------------------------------------------------------ 21 Important Notes ---------------------------------------------------------------------------------------------- 23 STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 2 STR5A464x Series 1. Absolute Maximum Ratings The polarity value for current specifies a sink as "+," and a source as "−," referencing the IC. Unless otherwise specified, TA = 25 °C, all S/GND pins (5 pin to 8pin) are shorted. The pin number of SOIC8 package products is shown in bracket. Parameter Symbol Test Conditions Pins Rating Units Remarks 1–5 FB Pin Voltage VFB − 0.3 to 7 V (2 – 5) 2–5 VCC Pin Voltage VCC −0.3 to 32 V (1 – 5) D/ST Pin Voltage VD/ST 4–5 −0.3 to 700 V Drain Peak Current Maximum Switching Current(1) (1) (2) IDP Single pulse, Within 500 ns pulse width, VD/ST ≤ 400 V 4–5 IDMAX Negative: Within 2 μs pulse width 4–5 (2) ― 1.7 −0.2 to 0.97 −0.2 to 0.91 1.55 A A MOSFET Power Dissipation PD1 Operating Ambient Temperature TOP ― −40 to 125 °C Storage Temperature TSTG ― −40 to 125 °C Junction Temperature TJ ― 150 °C 1.51 W STR5A464D STR5A464S STR5A464D STR5A464S See MOS FET Ta-PD curve. When embedding this hybrid IC onto the printed circuit board (cupper area in a 15mm×15mm) STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 3 STR5A464x Series 2. Electrical Characteristics The polarity value for current specifies a sink as "+," and a source as "−," referencing the IC. Unless otherwise specified, TA = 25 °C, all S/GND pins (5 pin to 8pin) are shorted. The pin number of SOIC8 package products is shown in bracket. Parameter Symbol Test Conditions Pins Min. Typ. Max. Units Remarks Power Supply Startup Operation 2–5 Operation Start Voltage VCC(ON) 13.6 15.0 16.6 V (1 – 5) 2–5 Operation Stop Voltage VCC(OFF) 7.3 8.0 8.7 V (1 – 5) 2–5 VCC = 12 V Circuit Current in Operation ICC(ON) ― ― 2.0 mA (1 – 5) Startup Circuit Operation VCC = 13.5 V VST(ON) 4–5 19 29 39 V Voltage 2–5 VCC = 13.5 V Startup Current ICC(ST) −2.7 −1.5 −0.5 mA VD/ST = 100 V (1 – 5) PWM Operation Average PWM Switching fOSC(AVG) VFB= 2.44 V 4–5 53 60 67 kHz Frequency Switching Frequency Δf 4–5 ― 2.8 ― kHz Modulation Deviation 1–5 Feedback Reference Voltage VFB(REF) 2.44 2.50 2.56 V (2 – 5) 1–5 VFB = 2.3 V Feedback Current(1) IFB(OP) −2.4 −0.8 ― μA (2 – 5) 1–5 Minimum Sampling Time tFBMS ― ― 2.5 μs (2 – 5) Standby Drain Current IDSTB 4–5 ― 50 ― mA Standby Operation Cycle tSTBOP 4–5 530 740 940 μs Maximum ON Duty DMAX 4–5 50 57 64 % Protection Leading Edge Blanking Time(1) tBW ― ― 230 ― ns Drain Current Limit IDLIM 4–5 0.37 0.41 0.45 A 2–5 OVP Threshold Voltage VCC(OVP) 27.5 29.3 31.3 V (1 – 5) VFB= 0 V OLP Delay Time at Startup tOLP 4–5 ― 72 ― ms Standby Blanking Time at VFB= 2.6 V tSTB(INH) 4–5 3.5 5.2 6.8 ms Startup Thermal Shutdown Operating TJ(TSD) ― 135 ― ― °C Temperature(1) Thermal Shutdown Hysteresis(1) TJ(TSD)HYS ― ― 70 ― °C Power MOSFET TJ = 125 °C Drain Leakage Current(1) IDSS 4–5 ― ― 50 µA On Resistance Switching Time Thermal Characteristics Thermal Resistance Junction to Case(1)(2) (1) (2) RDS(ON) tf θJ-C VD/ST = 560 V ID = 41 mA 4–5 4–5 ― ― 11.0 ― 13.6 250 Ω ns ― ― ― ― ― 15 16 °C/W STR5A464D STR5A464S Design assurance Case temperature (TC) measured at the center of the case top surface STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 4 STR5A464x Series 3. Mechanical Characteristics Parameter Conditions Package Weight 4. Min. Typ. Max. Unit Remarks — 0.51 — g STR5A464D — 0.078 — g STR5A464S Performance Curves ● STR5A464D Ambient Temperature versus Power Dissipation Curve Power Dissipation, PD (W) 1.25 1.00 0.75 0.50 0.25 10 Transient Thermal Resistance θJ-C (°C /W) PD_STR5A464D_R1 PD = 1.55 W 1.50 0.00 0 25 50 75 100 125 TR_STR5A464D_R1 Transient Thermal Resistance Curve 1.75 1 0.1 0.01 150 1μ 10μ Ambient Temperature, TA (°C ) 100μ 1m 10m 100m 10m 100m Time (s) ● STR5A464S Ambient Temperature versus Power Dissipation Curve 1.00 0.75 0.50 0.25 0.00 1 0.1 0.01 0 25 50 75 100 125 150 TR_STR5A464S_R1 Power Dissipation, PD (W) 1.25 10 Transient Thermal Resistance θJ-C (°C /W) PD = 1.51 W 1.50 Transient Thermal Resistance Curve PD_STR5A464S_R1 1.75 1μ 10μ Ambient Temperature, TA (°C ) STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 100μ 1m Time (s) 5 STR5A464x Series 5. Block Diagram The pin number of SOIC8 package products is shown in bracket. 2 (1) VCC STARTUP D/ST 4 UVLO OVP REG PROTECTION TSD DRV PWM OSC S Q R OCP 1 (2) FB S/H E/A Feedback Control VFB(REF) 6. LEB S/GND 5, 6, 7, 8 Pin Configuration Definitions ● DIP8 FB 1 VCC 2 D/ST Pin Name Descriptions 8 S/GND 1 FB 7 S/GND 2 VCC 6 S/GND 3 ― Constant voltage control signal input Power supply voltage input for control part and overvoltage protection (OVP) signal input (Pin removed) 4 D/ST 5 to 8 S/GND Pin Name 1 VCC MOSFET drain and startup current input 4 5 1 8 S/GND 2 7 S/GND 2 FB Descriptions Power supply voltage input for control part and overvoltage protection (OVP) signal input Constant voltage control signal input 6 S/GND 3 ― (Pin removed) 4 D/ST 5 S/GND 5 to 8 S/GND S/GND MOSFET source and ground ● SOIC8 VCC FB D/ST 4 MOSFET drain and startup current input MOSFET source and ground STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 6 STR5A464x Series 7. Typical Application Figure 7-1 and Figure 7-2 are the SOIC8 circuit example circuits of the buck and inverting converters. To enhance the heat dissipation, the wide pattern layout of the S/GND pin (5 through 8 pin) is recommended. When the absolute value of the output voltage | VOUT | is 27.5 V or more, add a Zenner diode DZ1 connected to D1 in serial as shown in Figure 7-3. Using the maximum on-duty of 50 % in the steady state operation, the condition of |VOUT| is shown below: | VOUT | : 11V < |VOUT | − VDZ1 < 27.5V | VOUT | according to the input voltage: For buck topology, | VOUT | ≤ 0.5 × input voltage For inverting topology, | VOUT | ≤ input voltage R2 D1 U1 VCC S/GND FB S/GND 1 DR1 R1 8 C4 C3 D2 7 2 FR1 R3 S/GND L1 L2 6 VOUT (+) S/GND D/ST 5 4 STR5A464S VAC C1 C2 D3 C5 R4 (-) Figure 7-1. Buck Converter R2 D1 U1 VCC S/GND FB S/GND 1 DR1 R1 8 C4 C3 D2 7 2 FR1 R3 S/GND L1 6 VOUT (-) D3 D/ST S/GND 4 5 STR5A464S VAC C1 C2 L2 C5 R4 (+) Figure 7-2. Inverting Converter VCC S/GND Figure 7-3. Increasing the Absolute Value of |VOUT| STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 7 STR5A464x Series 8. Physical Dimensions ● DIP8 9.4±0.3 5 1 4 6.5 ±0.2 8 1.52+0.3 -0.05 7.6 TYP 3.3 ±0.2 4.2±0.3 3.4 ±0.1 7.5±0.5 1.0+0.3 -0.05 0.2 +0. 5 1 -0. 05 2.54 TYP 0~15° 0~15° 0.89 TYP 0.5±0.1 NOTES: – All dimensions in millimeters – Pb-free (RoHS compliant) – When soldering the products, it is required to minimize the working time within the following limits: Flow: 260 °C / 10 s, 1 time Soldering Iron: 350 °C / 3.5 s, 1 time Soldering should be at a distance of at least 1.5 mm from the body of the product. STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 8 STR5A464x Series ● SOIC8 NOTES: – All dimensions in millimeters – Pb-free (RoHS compliant) – When soldering the products, it is required to minimize the working time within the following limits: Flow: 260 °C / 10 s, 1 time Soldering Iron: 350 °C / 3.5 s, 1 time ● SOIC8 Land Pattern Example 1.6 3.8 1.27 0.61 Unit: mm STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 9 STR5A464x Series 9. Marking Diagram ● DIP8 8 5A464D Specific Device Code (See Table 9-1) S KY MD 1 Lot Number: Y is the last digit of the year of manufacture (0 to 9) M is the month of the year (1 to 9, O, N, or D) D is the period of days represented by: 1: the first 10 days of the month (1st to 10th) 2: the second 10 days of the month (11th to 20th) 3: the last 10–11 days of the month (21st to 31st) Sanken Control Number ● SOIC8 8 5A464S Specific Device Code (See Table 9-1) S KY MD 1 Y is the last digit of the year of manufacture (0 to 9) M is the month of the year (1 to 9, O, N, or D) D is the period of days represented by: 1: the first 10 days of the month (1st to 10th) 2: the second 10 days of the month (11th to 20th) 3: the last 10–11 days of the month (21st to 31st) Sanken Control Number Table 9-1. Specific Device Code Specific Device Code Part Number 5A464D STR5A464D 5A464S STR5A464S STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 10 STR5A464x Series 10. Operational Description All of the parameter values used in these descriptions are typical values, unless they are specified as minimum or maximum. With regard to current direction, "+" indicates sink current (toward the IC) and "–" indicates source current (from the IC). In Section 8, the pin number of SOIC8 package products is shown in bracket. The common items of Buck converter and Inverting are desribed by using Buck conveter. Figure 10-1). The voltage between VCC pin and S/GND pin in the steady state operation is calculated as follows, where VFD1, VFD2 and VFD3 are the forward voltage of D1, D2 and D3 respectively: VCC = VOUT + VFD3 − (VFD1 + VFD2 ) (2) 10.2 Undervoltage Lockout (UVLO) Figure 10-2 shows the relationship of VCC pin voltage and the circuit current, ICC. When VCC pin voltage increases to VCC(ON) = 15.0 V, the control circuit starts switching operation and the circuit current, ICC, increases. When VCC pin voltage decreases to VCC(OFF) = 8.0 V, the control circuit stops its operation by the Undervoltage Lockout (UVLO) circuit, and reverts to the state before startup. 10.1 Startup Operation of IC Figure 10-1 shows the circuit around VCC pin. ISTRTUP Contro1 VCC 2(1) D/ST C2 S/GND L2 5~8 C5 R4 Stop VIN Circuit current, ICC Start VOUT (+) 4 (-) Figure 10-1. VCC Pin Peripheral Circuit in Buck Converter The IC incorporates the startup circuit. The circuit is connected to D/ST pin. When D/ST pin voltage reaches the Startup Circuit Operation Voltage VST(ON) = 29 V, the startup circuit starts operation. During the startup process, the constant current, ICC(ST) = −1.5 mA, charges C4 at VCC pin. When VCC pin voltage increases to VCC(ON) = 15.0 V, the control circuit starts switching operation. After switching operation begins, the startup circuit turns off automatically so that its current consumption becomes zero. The approximate startup time tSTART is calculated as follows: t START = C4 × VCC(ON) − VCC(INT) |ICC(ST) | (s) (1) where, tSTART is the startup time of IC (s), VCC(INT) is the initial voltage on VCC pin (V). When the internal power MOSFET turns off, the output voltage, VOUT, charges C4 through D1 and D2 (see to VCC(OFF) VCC pin VCC(ON) voltage Figure 10-2. Relationship between VCC Pin Voltage and ICC 10.3 Power Supply Startup and Soft Start Function The soft start function reduces the voltage and the current stress of the internal power MOSFET and the freewheeling diode, D3. Figure 10-3 shows the startup waveforms. After the IC starts, during the Standby Blanking Time at Startup, tSTB(INH), the burst oscillation mode is disabled to operate the soft start. The IC activates the soft start circuitry during the startup period. The soft start time is fixed to about 5.2 ms. During the soft start period, the overcurrent threshold is increased step-wisely (7 steps). The IC operates switching operation by the frequency responding to FB pin voltage until the output reaches the setting voltage. Here, the tLIM is defined as the period until FB pin voltage reaches 1.6 V after the IC starts. When the tLIM reaches the OLP Delay Time at Startup, tOLP, of 72 ms and more, the IC stops switching operation. Thus, it is STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 11 STR5A464x Series necessary to adjust the value of output electrolytic capacitor, C5 so that the tLIM is less than tOLP. If VCC pin voltage reaches VCC(OFF) and a startup failure occurs as shown in Figure 10-4, increase C4 value or decrease C5 value. Since the larger capacitance causes the longer startup time of IC, it is necessary to check and adjust the startup process based on actual operation in the application. Since the leading edge blanking function (see Section 10.5) is disabled during the soft start period, the on-time may be less than the Leading Edge Blanking Time (tBW = 230 ns). VCC pin voltage sampled FB pin voltage on pulse by pulse basis at the point of tFBFS = 2.5 μs (max.) after turning off the internal power MOSFET. The VROCP is the voltage value of the built-in drain current sense resistor. The IC controls so that the peak voltage of VROCP is close to VSC by comparing them at the internal FB comparator (see Figure 10-5 and Figure 10-6). U1 Startup of IC Normal opertion Startup of SMPS tSTART 4 D/ST Feedback Control E/A FB comp VSC + S/H + PWM Control VROCP ROCP VCC(ON) VCC(OFF) R2 1(2) FB D2 R1 L2 VOUT (+) 5~8 S/GND ILON C2 R3 D3 C5 tSTB(INH) R4 (-) Time Soft start period, fixed to approximately 5.2 ms for STR5A464 D/ST pin current, ID Figure 10-5. FB Pin Peripheral Circuit in Buck Converter Time FB pin voltage VFB(REF) tLIM < tOLP - VSC + VROCP FB comparator Voltage on both side of ROCP 1.6V Time Drain current, ION Figure 10-3. Startup Waveforms VCC pin voltage Startup success IC starts operation Target operating voltage VCC(ON) Increase with rising of output voltage VCC(OFF) Startup failure Time Startup time of IC, tSTART Figure 10-4. VCC Pin Voltage during Startup Period 10.4 Constant Voltage (CV) Control The constant voltage (CV) control for power supply output adopts the peak-current-mode control method which enhances the response speed and the stable operation. The target voltage, VSC, is made from the voltage value Figure 10-6. Drain Current ID and FB Comparator in Steady State Operation ● Decreasing Load When the output load decreases, the FB pin voltage increases in response to the increase of the output voltage. Since VSC which is the output voltage of internal error amplifier becomes low, the peak value of VROCP is controlled to become low, and the peak of the drain current decreases. This control prevents the output voltage from increasing. ● Increasing Load When the output load increases, the control circuit operates the reverse of the former operations. Since VSC becomes high, the peak drain current increases. This control prevents the output voltage from decreasing. STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 12 STR5A464x Series 10.4.1 Buck Converter Operation Figure 10-7 shows the output current path in the Buck converter. Figure 10-8 shows the operational waveforms. Contro1 VCC 2(1) FB 1(2) VROC P ROCP 4 C2 VIN L2 5~8 D/ST S/GND ILON (MOSFET on) ILOFF (MOSFET off) C5 VOUT (+) R4 (-) 2) PWM Off-Time Period When the internal power MOSFET turns off, the back electromotive force occurs in the inductor, L2, the freewheeling diode, D3, is forward biased and turns on. Thus, the ILOFF current flows as shown in Figure 10-7. As shown in Figure 10-8, after the average switching period, 1⁄fOSC(AVG) ), the power MOSFET turns on again, and the event moves to the previous 1). The output current is equal to the average inductor current of L2. 10.4.2 Inverting Converter Operation Figure 10-9 shows the output current path in the Inverting converter. Figure 10-10 shows the operational waveforms. Figure 10-7. Output Current Path in Buck Converter VCC 2(1) FB 1(2) Contro1 VL MOSFET ON OFF ON VIN-VRON-VOUT VROC P ROCP 0 4 t -(VOUT+VFD3) VOUT (-) 5~8 D/ST S/GND C2 IL VIN ILON (MOSFET on) t ILOFF (MOSFET off) C5 R4 L2 (+) ILON t ILOFF Figure 10-9. Output Current Path in Inverting Converter t 1/fOSC(AVG) Figure 10-8. Operational Waveforms in Buck Converter MOSFET ON OFF VL VIN-VRON t 0 In the Buck converter, the PWM control is described in the following. 1) PWM On-Time Period When the internal power MOSFET turns on, the ILON current flows as shown in Figure 10-7, and the inductor, L2, stores some energy. Since the ILON flows through the internal sense resistor, ROCP, the voltage of ROCP is detected as the current detection voltage, VROCP. FB pin voltage is the voltage divided C3 voltage by voltage dividing resistors, and the target voltage, VSC, is given by FB pin voltage. When VROCP reaches VSC, the power MOSFET turns off. ON -(VOUT+VFD3) IL t ILON t ILOFF t 1/fOSC(AVG) Figure 10-10. STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 Operational Waveforms in Inverting Converter 13 STR5A464x Series In the Inverting converter, the PWM control is described in the following. 1) PWM On-Time Period When the internal power MOSFET turns on, the ILON current flows as shown in Figure 10-9, and the inductor, L2, stores some energy. Since the ILON flows through the internal sense resistor, ROCP, the voltage of ROCP is detected as the current detection voltage, VROCP. FB pin voltage is the voltage divided C3 voltage by voltage dividing resistors, and the target voltage, VSC, is given by FB pin voltage. When VROCP reaches VSC, the power MOSFET turns off. 2) PWM Off-Time Period When the internal power MOSFET turns off, the back electromotive force occurs in the inductor, L2, the freewheeling diode, D3, is forward biased and turns on. Thus, the ILOFF current flows as shown in Figure 10-9. As shown in Figure 10-10, after the average switching period, 1⁄fOSC(AVG) , the power MOSFET turns on again, and the event moves to the previous 1). The output current is equal to the average current of ILOFF of L2. 10.5 Leading Edge Blanking Function The constant voltage control for power supply output adopts the peak-current-mode control method. The peak drain current is detected by the internal sense resistor, ROCP. Just in turning on the internal power MOSFET, the steep surge current would occur. If the overcurrent protection (OCP) responds to the voltage caused by that surge current, the power MOSFET may be turned off. To prevent that response, the OCP detection is disabled during Leading Edge Blanking (tBW = 230 ns) just after the power MOSFET turns on. function reduces the conduction noise compared with other products without this function, and simplifies noise filtering of the input lines of power supply. 10.7 Operation Mode As shown in Figure 10-12, when the output power is decreasing, together with the decrease of the drain current ID of the internal power MOSFET, the operation mode is automatically changed to the fixed switching frequency mode (60 kHz), to the green mode controlled the switching frequency (23 kHz to 60 kHz), and to the burst oscillation mode controlled by an internal oscillator. In the green mode, the number of switching is reduced. In the burst oscillation mode, the switching operation is stopped during a constant period. Thus, the switching loss is reduced, and the power efficiency is improved. When the output power becomes light and the drain current decreases to the Standby Drain Current, IDSTB, the burst oscillation mode is getting started. Figure 10-13 shows the drain current waveforms of point A and B in Figure 10-12. The burst period of burst oscillation mode is the Standby Operation Cycle, tSTBOP = 740 μs. In the burst period, the number of minimum switching times is reduced up to one. Since the oscillator for setting burst oscillation cycle and the oscillator for setting the switching oscillation frequency are not synchronized each other, the first switching frequency in the burst period may be raised. Switching Frequency, fOSC Fixed switching frequency 60kHz B About 23kHz Burst oscillation mode Green mode tSTBOP = 740 µs PO Figure 10-12. tBW ROCP voltage A Output power Switching Frequency in Response to Output Power Point A ID Time Surge pulse voltage width at turning on Figure 10-11. Point B ID Leading Edge Blanking tSTBOP Time 10.6 Random Switching Function The switching frequency is randomly modulated by superposing the modulating frequency on fOSC(AVG). This Figure 10-13. Switching Waveform at Burst Oscillation Mode STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 14 STR5A464x Series 10.8 Overload Protection (OLP) When the drain current, ID, reaches the Drain Current Limit, IDLIM, the internal power MOSFET turns off. Figure 10-14 shows the characteristic of output voltage and current. The output voltage decreases in the overload state, and FB pin voltage also decreases. When the period keeping FB pin voltage less than 1.6 V continues during the OLP Delay Time at Startup (tOLP = 72 ms), the overload protection (OLP) is activated, and the IC stops switching operation. Thus, VCC pin voltage decreases to VCC(OFF), and the control circuit stops operation. After that, the startup circuit is activated, VCC pin voltage increases to VCC(ON) by the startup current, and the control circuit operates again. Thus, the intermittent operation by UVLO is repeated in the OLP state (see Figure 10-15). This intermittent operation reduces the stress of parts including the power MOSFET and the freewheeling diode. In addition, this operation reduces power consumption because the switching period in this intermittent operation is much shorter than the oscillation stop period. When the abnormal condition is removed, the IC returns to normal operation automatically. Output voltage, VOUT CV mode Output current, IOUT Figure 10-14. Overload Characteristics Non-switching interval VOUT(OVP) = VCC(OVP) + VFD1 + VFD2 − VFD3 (3) where, VOUT(OVP) is voltage of between VOUT(+) and VOUT(−), VFD1 is the forward voltage of D1 in Figure 10-1, VFD2 is the forward voltage of D2, and VFD3 is the forward voltage of D3. 10.10 Thermal Shutdown (TSD) Figure 10-16 shows the thermal shutdown (TSD) operational waveforms. When the junction temperature of the IC control circuit increases to TJ(TSD) = 135 °C (min.) or more, the TSD is activated, and the IC stops switching operation. The TSD has a temperature hysteresis. When VCC pin voltage decreases to about 9.4 V during the TJ > (TJ(TSD)−TJ(TSD)HYS), the startup circuit supplies startup current to VCC pin to keep the VCC pin voltage > VCC(OFF). While the junction temperature is TJ(TSD)−TJ(TSD)HYS or less, the startup circuit stops the startup current supply. Then, VCC pin voltage decreases to VCC(OFF) or less, and the control circuit stops operation. After that, the startup circuit is activated, VCC pin voltage increases to VCC(ON) by the startup current, and the control circuit operates again. The intermittent operation by TSD and UVLO is repeated in the TSD state. After the fault condition is removed, the IC returns to normal operation automatically. Junction temperature, Tj VCC pin voltage VCC(ON) TSD is active Return to normal operation Tj(TSD) VCC(OFF) Drain current, ID intermittent operation by UVLO. When the abnormal condition is removed, the IC returns to normal operation automatically. The approximate value of output voltage VOUT(OVP) in the OVP condition is calculated by using Equation (3). Tj(TSD)−Tj(TSD)HYS tOLP tOLP ON Bias Assist Function OFF OFF VCC pin voltage Figure 10-15. VCC(ON) VCC(BIAS) VCC(OFF) OLP Operational Waveform 10.9 Overvoltage Protection (OVP) When the voltage between VCC pin and S/GND pin increases to VCC(OVP) = 29.3 V or more, the overvoltage protection (OVP) is activated and the IC stops switching operation. The intermittent operation by UVLO is repeated in the OVP state. See Section 10.8 about the Drain current, ID Figure 10-16. STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 TSD Operational Waveforms 15 STR5A464x Series 11. Design Notes 11.1.2 Inductor 11.1 External Components Take care to use properly rated, including derating as necessary, and proper type of components. Figure 11-1 shows the peripheral circuit of IC in Buck converter. The pin number of SOIC8 package products in the circuits is shown in bracket. R2 R3 R1 U1 D1 VCC S/GND FB S/GND 1 (2) 7 2 (1) S/GND FR1 DR1 L1 D/ST 4 VAC C1 C2 8 C3 C4 D2 VOUT 6 L2 (+) S/GND 5 D3 C5 R4 Apply proper design margin to core temperature rise by core loss and copper loss. The inductor should be designed so that the inductor current does not saturate. The inductance should be the minimum considered a negative tolerance of inductance and a decline of DC superposition characteristics. The on-time must be longer than the Leading Edge Blanking Time to control the output voltage constantly. In the universal input voltage design, the on-time is easy to become short in the condition of maximum AC input voltage and light load. Be careful not to choose too small value for the inductance (The recommended value is 600 μH or more). Refer to the following design example of how to the inductor setting of the buck converter. ● DEE0012 Design Example Using STR5A464S: 3 W (15 V, 0.2 A) Offline Buck Converter https://www.semicon.sankenele.co.jp/common/pdf/designexample/dee0012.pdf (-) 11.1.3 VCC Pin Peripheral Circuit Figure 11-1. Peripheral Circuit of IC in Buck Converter The reference value of C4 in Figure 11-1 is generally 10 to 47 μF. See Section 10.1 about the startup time. 11.1.1 Input and Output Electrolytic Capacitor 11.1.4 FB Pin Peripheral Circuit Apply proper derating to ripple current, voltage, and temperature rise. The value of output electrolytic capacitor, C5, should be fulfilled the following conditions: - The specification of output ripple - Enough shorter output voltage rising time in startup than the OLP Delay Time at Startup, tOLP = 72 ms. - Low impedance types, designed for switch mode power supplies, is recommended. The ESR of C5 should be set in the range of Equation (4). ZCO < ∆VOR ILRP (4) As shown in Figure 11-1, FB pin is input the voltage divided the voltage between VOUT(+) and S/GND pin by resistors. C3 is the smoothing capacitor. The value of C3 depends on the value of output electrical capacitor, C5. Usually the value of C3 is 0.068 μF to 0.47 μF. When C3 value is set larger, the line regulation becomes better, however, the dynamic response of the output voltage becomes worse. Be careful of that value. The voltage dividing resistor of R1, R2 and R3 is determined by the reference voltage, VFB(REF) = 2.50 V, the output voltage, VOUT, and so on. The following Equation (5) shows the relationship of them. The target value of R1 is about 5.6 kΩ to 10 kΩ. R2 and R3 should be adjusted in actual operation condition. The VF of D2 and D3 affects the output voltage. Thus, the diodes of low VF should be selected. where, ZCO is the ESR of electrolytic capacitor at the operation frequency (Since the ESR in general catalogs is mostly measured at 100 kHz, check the frequency characteristic.), ΔVOR is the output ripple voltage specification, and ILRP is the ripple current of inductor. STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 16 STR5A464x Series 11.3 PCB Trace Layout R1 + R2 + R3 |VOUT | ≅ VFB(REF) × + VFD2 − VFD3 R1 ⇒ R2 + R3 = ( |VOUT |−VFD2 + VFD3 − 1) VFB(REF) × R1 (5) 1) Main Circuit Trace Layout This is the main trace containing switching currents, and thus it should be as wide trace and small loop as possible. where, VFD2 is the forward voltage of D2, and VFD3 is the forward voltage of D3. 11.1.5 Freewheeling Diode D3 in Figure 11-1 is the freewheeling diode. When the internal power MOSFET turns on, the recovery current flows through D3. The current affects power loss and noise much. The VF affects the output voltage. Thus, the diode of fast recovery and low VF should be selected. 11.1.6 Bleeder Resistance For light load application, the bleeder resistor, R4, in Figure 11-1 should be connected to both ends of output capacitor, C5, to prevent the increase of output voltage. The value of R4 should be satisfied with Equation (6), and should be adjusted in actual operation condition. R4 ≤ |VOUT | 3mA Since the PCB circuit trace design and the component layout significantly affects operation, EMI noise, and power dissipation, the high frequency PCB trace should be low impedance with small loop and wide trace. In addition, the ground traces affect radiated EMI noise, and wide, short traces should be taken into account. Figure 11-2 and Figure 11-3 show the circuit design example. (6) 11.2 D/ST Pin When the D/ST pin voltage and the current exceed the Absolute Maximum Ratings, the internal power MOSFET connected to D/ST pin would be permanently damaged. The D/ST pin voltage should be less than 630 V which is the derating value of 90% for the Absolute Maximum Ratings, 700 V, in all condition of actual operation, and the parameters of transformer and components value should be selected based on actual operation in the application. In addition, the D/ST pin voltage should be less than 560 V in the steady state operation. 2) Freewheeling Loop Layout This is the trace for the current of freewheeling diode, D3, and thus it should be as wide trace and small loop as possible. 3) Control Ground Trace Layout Since the operation of IC may be affected from the large current of the main trace that flows in control ground trace, the control ground trace should be separated from main trace and connected at single point grounding. 4) VCC Trace Layout This is the trace for supplying power to the IC, and thus it should be as small loop as possible. If C4 and the IC are distant from each other, placing a capacitor such as film capacitor Cf (about 0.1 μF to 1.0 μF) close to the VCC pin and the S/GND pin is recommended. 5) FB Trace Layout The divided voltage by R2+R3 and R1 of output voltage is input to the FB pin. To increase the detection accuracy, R3 and R1 should be connected to the bottom of C3 and the S/GND pin, respectively. The trace between R1, R2 and the FB pin should be as short as possible. 6) Thermal Considerations Since the internal power MOSFET has a positive thermal coefficient of RDS(ON), consider it in thermal design. Since the copper area under the IC and the S/GND pin trace act as a heatsink, its traces should be as wide as possible. STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 17 STR5A464x Series (6) Trace of S/GND pin should be wide for heat release D1 D2 (4) Loop of the power supply should be small R3 (5) The trace between R1, R2 and FB pin should be as short as possible. R2 1 8 S/GND FB C3 C4 2 7 S/GND VCC R1 6 S/GND 4 VOUT (+) 5 D/ST S/GND L2 U1 C5 D3 C2 R4 (-) (2) Freewheeling loop trace should be wide trace and small loop (1)Main trace should be wide trace and small loop (3) Control ground trace should be connected at a single point Figure 11-2. Peripheral Circuit Example Around IC for Buck Converter (DIP8) (6) Trace of S/GND pin should be wide for heat release D1 D2 (4) Loop of the power supply should be small R3 (5) The trace between R1, R2 and FB pin should be as short as possible. R2 1 FB S/GND VCC S/GND 8 C3 C4 2 R1 7 6 S/GND 4 VOUT (-) D3 5 D/ST S/GND U1 C2 C5 R4 L2 (+) (1)Main trace should be wide trace and small loop (2) Freewheeling loop trace should be wide trace and small loop (3) Control ground trace should be connected at a single point Figure 11-3. Peripheral Circuit Example Around IC for Inverting Converter (DIP8) STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 18 STR5A464x Series 12. Pattern Layout Example (Buck Converter) The following show the pattern layout example and the circuit schematic for the buck converter using STR5A464S. The design example uses only the parts listed in the circuit diagram and the bill of materials. PCB dimensions: 65 mm × 24 mm (a) Top View (b) Bottom View Figure 12-1. Pattern Layout Example for Buck Converter STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 19 STR5A464x Series R2 D1 U1 VCC S/GND FB S/GND 1 FR1 DR1 L1 R1 8 C4 D2 C3 7 2 P1 R3 S/GND JP1 D/ST 6 L2 P2 S/GND 4 (+) 5 STR5A464S C1 C2 D3 C5 R4 P3 (-) PSA50143 Rev.1.0 Figure 12-2. Circuit Diagram for Buck Converter STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 20 STR5A464x Series 13. Design Example The following show the power supply specification, the circuit schematic, and the bill of materials of the buck converter reference design. ● Power Supply Specification IC Input voltage Maximum output power Output voltage Output current STR5A464S 85 VAC to 265 VAC 3W 15 V 0.2 A ● Circuit Diagram R2 D1 U1 VCC S/GND FB S/GND 1 FR1 DR1 L1 R1 8 C4 D2 C3 7 2 P1 R3 S/GND JP1 D/ST 6 L2 P2 S/GND 4 (+) 5 STR5A464S C1 C2 D3 C5 R4 P3 (-) PSA50143 Rev.1.0 Figure 13-1. Circuit Diagram for Buck Converter STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 21 STR5A464x Series ● Bill of Materials Symbol Part Type Ratings Recommended Sanken Parts C1 Electrolytic capacitor 105 °C, 400 V, 8.2 µF C2 Electrolytic capacitor 105 °C, 400 V, 8.2 µF C3 Ceramic capacitor 50 V, 0.22 µF, 2012 C4 Electrolytic capacitor 105 °C, 50 V, 10 µF C5 Electrolytic capacitor 105 °C, 25 V, 470 µF General-purpose rectifier diode 1000 V, 1 A EM1C D1 Schottky diode 90 V, 1 A SJPB-D9 D2 Fast recovery diode 500 V, 1 A SJPD-D5 D3 Fast recovery diode 500 V, 1 A SJPD-D5 L1 Inductor 1 mH, 0.21 A L2 Inductor 1 mH, 0.5 A FR1 Resistor 2 W, 10 Ω R1 Chip resistor 6.8 kΩ, 1/8 W, 1608 R2 Chip resistor 33 kΩ, 1/8 W, 1608 R3 Chip resistor 1.8 kΩ, 1/8 W, 1608 R4 Chip resistor 6.8 kΩ, 1/8 W, 1608 U1 PWM offline converter IC 700 V, 13.6 Ω JP1 Jumper wire Plated wire (φ = 0.6, P = 5 mm) P1 250 V P2 Connector Connector P3 Connector 50 V ― PCB PSA50143 Rev.1.0 DR1 STR5A464S 50 V STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 22 STR5A464x Series Important Notes ● All data, illustrations, graphs, tables and any other information included in this document (the “Information”) as to Sanken’s products listed herein (the “Sanken Products”) are current as of the date this document is issued. The Information is subject to any change without notice due to improvement of the Sanken Products, etc. Please make sure to confirm with a Sanken sales representative that the contents set forth in this document reflect the latest revisions before use. ● The Sanken Products are intended for use as components of general purpose electronic equipment or apparatus (such as home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the Sanken Products, please put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken. When considering use of the Sanken Products for any applications that require higher reliability (such as transportation equipment and its control systems, traffic signal control systems or equipment, disaster/crime alarm systems, various safety devices, etc.), you must contact a Sanken sales representative to discuss the suitability of such use and put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken, prior to the use of the Sanken Products. The Sanken Products are not intended for use in any applications that require extremely high reliability such as: aerospace equipment; nuclear power control systems; and medical equipment or systems, whose failure or malfunction may result in death or serious injury to people, i.e., medical devices in Class III or a higher class as defined by relevant laws of Japan (collectively, the “Specific Applications”). Sanken assumes no liability or responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, resulting from the use of the Sanken Products in the Specific Applications or in manner not in compliance with the instructions set forth herein. ● In the event of using the Sanken Products by either (i) combining other products or materials or both therewith or (ii) physically, chemically or otherwise processing or treating or both the same, you must duly consider all possible risks that may result from all such uses in advance and proceed therewith at your own responsibility. ● Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the occurrence of any failure or defect or both in semiconductor products at a certain rate. You must take, at your own responsibility, preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which the Sanken Products are used, upon due consideration of a failure occurrence rate and derating, etc., in order not to cause any human injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products. Please refer to the relevant specification documents and Sanken’s official website in relation to derating. ● No anti-radioactive ray design has been adopted for the Sanken Products. ● The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples, all information and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of use of the Sanken Products. ● Sanken assumes no responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, or any possible infringement of any and all property rights including intellectual property rights and any other rights of you, users or any third party, resulting from the Information. ● No information in this document can be transcribed or copied or both without Sanken’s prior written consent. ● Regarding the Information, no license, express, implied or otherwise, is granted hereby under any intellectual property rights and any other rights of Sanken. ● Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied, including, without limitation, any warranty (i) as to the quality or performance of the Sanken Products (such as implied warranty of merchantability, and implied warranty of fitness for a particular purpose or special environment), (ii) that any Sanken Product is delivered free of claims of third parties by way of infringement or the like, (iii) that may arise from course of performance, course of dealing or usage of trade, and (iv) as to the Information (including its accuracy, usefulness, and reliability). ● In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and regulations that regulate the inclusion or use or both of any particular controlled substances, including, but not limited to, the EU RoHS Directive, so as to be in strict compliance with such applicable laws and regulations. ● You must not use the Sanken Products or the Information for the purpose of any military applications or use, including but not limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Information, or providing them for non-residents, you must comply with all applicable export control laws and regulations in each country including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan, and follow the procedures required by such applicable laws and regulations. ● Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including the falling thereof, out of Sanken’s distribution network. ● Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting from any possible errors or omissions in connection with the Information. ● Please refer to our official website in relation to general instructions and directions for using the Sanken Products, and refer to the relevant specification documents in relation to particular precautions when using the Sanken Products. ● All rights and title in and to any specific trademark or tradename belong to Sanken and such original right holder(s). DSGN-CEZ-16003 STR5A464x-DSE Rev.3.7 SANKEN ELECTRIC CO., LTD. Nov. 10, 2023 https://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 23
STR5A464S 价格&库存

很抱歉,暂时无法提供与“STR5A464S”相匹配的价格&库存,您可以联系我们找货

免费人工找货
STR5A464S
    •  国内价格
    • 1+4.36884
    • 10+4.02739
    • 50+3.94859
    • 100+3.77349
    • 200+3.71220

    库存:0

    STR5A464S
      •  国内价格 香港价格
      • 1+12.749051+1.54840
      • 10+8.4886110+1.03096
      • 50+7.5122650+0.91238
      • 100+6.68922100+0.81242
      • 500+6.68115500+0.81144
      • 1000+6.665011000+0.80948
      • 2000+6.632742000+0.80556
      • 4000+6.600464000+0.80164

      库存:0