SUK3015

SUK3015

  • 厂商:

    SANKEN(三垦)

  • 封装:

    TO-263(D²Pak)

  • 描述:

    表面贴装型 N 通道 300 V 15A(Ta) 89W(Tc) TO-220S

  • 数据手册
  • 价格&库存
SUK3015 数据手册
V(BR)DSS = 300 V, RDS(ON) = 0.15 Ω N-channel Power MOSFET SUK3015 Data Sheet Description Package SUK3015 includes a low on-resistance N-channel power MOSFET with Zener diode for ESD protection. The package of SUK3015 is TO220S-2L that is surface mount package and high heat release. TO220S-2L (4) (4) Features ● Suitable for High Reliability and Automotive Requirement ● Bare Lead Frame: Pb-free (RoHS Compliant) ● Low On-resistance ● Gate-to-Source ESD Protection Zener Diode ● 100% Avalanche Tested ● V(BR)DSS ------------------------------ 300 V (ID = 100 μA) ● ID ------------------------------------------------------ ±15 A ● RDS(ON) -------------- 0.15 Ω max. (ID = 7 A, VGS =10 V) ● trr----------------------------------------------- 160 ns (typ.) Applications (1) (2) (3) (3) (2) (1) Not to scale (2)(4) (1) Gate (2) Drain (3) Source (4) Drain (1) ● DC/DC Converter ● Other Switched-mode Power Supply (3) SUK3015-DSE Rev.1.2 SANKEN ELECTRIC CO., LTD. Feb. 28, 2022 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2016 1 SUK3015 Absolute Maximum Ratings Unless otherwise specified, TA = 25 °C. Parameter Symbol Conditions Rating Unit Drain-to-Source Voltage VDS 300 V Gate-to-Source Voltage VGS ±25 V Continuous Drain Current ID ±15 A Pulsed Drain Current IDM ±60 A Avalanche Energy EAS 50 mJ Avalanche Current IAS 26.7 A Power Dissipation PD 89 W 3.0 V/ns 8.5 V/ns 190 A/µs Maximum Drain-to-Source dv/dt 1 ‘dv/dt1 Maximum Diode Recovery dv/dt 2 ‘dv/dt2 Pulse width ≤ 100 µs, duty cycle ≤ 1 % VDD = 49 V, L = 120 µH, IAS =26.7 A, VGS = 16 V, RG = 0 Ω, unclamped; see Figure 1. TC = 25 °C VDD = 49 V, L = 120 µH, IAS =26.7 A, VGS = 16 V, RG = 0 Ω, unclamped; see Figure 1. VDD = 200 V, L = 0.2 mH, ISDP = 15 A; see Figure 2. VDD = 200 V, L = 0.2 mH, ISDP = 15 A; see Figure 2. Maximum Diode Recovery di/dt ‘di/dt Operating Junction Temperature TJ 150 °C TSTG −55 to 150 °C Storage Temperature SUK3015-DSE Rev.1.2 SANKEN ELECTRIC CO., LTD. Feb. 28, 2022 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2016 2 SUK3015 Electrical Characteristics Unless otherwise specified, TA = 25 °C. Parameter Symbol Drain-to-Source Breakdown V(BR)DSS Voltage Drain-to-Source Leakage Current IDSS Gate-to-Source Leakage Current Gate Threshold Voltage Static Drain-to-Source On-resistance Input Capacitance Conditions Min. Typ. Max. Unit ID = 100 μA, VGS = 0 V 300 — — V VDS = 300 V, VGS = 0 V — — 100 µA VGS = ±20 V — — 10 µA VGS(TH) VDS = 10 V, ID = 1 mA 1.5 2.0 2.5 V RDS(ON) ID = 7 A, VGS = 10 V — — 0.15 Ω — 1800 — — 420 — — 85 — VDD = 200 V, ID = 7 A, VGS = 10 V, RG = 15.6 Ω, RL = 28.6 Ω; see Figure 3. — 15 — — 34 — — 112 — — 144 — ISD = 7 A, VGS = 0 V — — 1.2 V ISDP = 15 A, di/dt = 100 A/µs; see Figure 2. — 160 — ns Conditions Min. Typ. Max. Unit — — 1.4 °C/W Min. Typ. Max. Unit ― 1.4 ― g IGSS Ciss Output Capacitance Coss Reverse Transfer Capacitance Crss Turn-on Delay Time td(ON) Turn-on Rise Time Turn-off Delay Time Turn-off Fall Time Source-to-Drain Diode Forward Voltage Source-to-Drain Diode Reverse Recovery Time tr td(OFF) tf VSD trr VDS = 10 V, VGS = 0 V, f = 1 MHz pF ns Thermal Characteristics Parameter Thermal Resistance (Junction-to-Case) Symbol RθJC Mechanical Characteristics Parameter Conditions Package Weight SUK3015-DSE Rev.1.2 SANKEN ELECTRIC CO., LTD. Feb. 28, 2022 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2016 3 SUK3015 L VDS V(BR)DSS dv/dt1 ID VDS VDD 0 RG VDD VGS ID IDP 0V 0 (a) Test Circuit (b) Waveform Unclamped Inductive Switching Energy Test Figure 1. ISD RL ISDP trr 0 VDS RG VGS ID 2A IRM × 90% di/dt VDD IRM VDS dv/dt2 0V VDD 150 V 100 V Pulse width = 10 μs Duty cycle 1% 0 (a) Test Circuit (b) Waveform Figure 2. Diode Reverse Recovery Time Test SUK3015-DSE Rev.1.2 SANKEN ELECTRIC CO., LTD. Feb. 28, 2022 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2016 4 SUK3015 VGS RL 90% 10% 0 VDS RG VGS ID VDS 90% VDD 10% 0 0V td(ON) tr Pulse width = 10 μs Duty cycle 1% td(OFF) tf tON (a) Test Circuit tOFF (b) Waveform Figure 3. Resistive Load Switching Time Test SUK3015-DSE Rev.1.2 SANKEN ELECTRIC CO., LTD. Feb. 28, 2022 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2016 5 SUK3015 Derating Curve Figure 4. PD vs. TC Typical Characteristic Curves Figure 5. Safe Operating Area SUK3015-DSE Rev.1.2 SANKEN ELECTRIC CO., LTD. Feb. 28, 2022 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2016 Figure 6. ID vs. VDS 6 SUK3015 Figure 7. Figure 9. ID vs. VGS RDS(ON) vs. TC Figure 8. Figure 10. SUK3015-DSE Rev.1.2 SANKEN ELECTRIC CO., LTD. Feb. 28, 2022 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2016 RDS(ON) vs. ID Capacitance vs. VDS 7 SUK3015 Figure 11. Figure 13. V(BR)DSS vs. TC VDS vs. QG SUK3015-DSE Rev.1.2 SANKEN ELECTRIC CO., LTD. Feb. 28, 2022 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2016 Figure 12. Figure 14. ISD vs. VSD VGS(TH) vs. TC 8 Junction–Case Thermal Resistance (°C/W) SUK3015 Pulse Width (s) Figure 15. Transient Thermal Resistance Characteristics SUK3015-DSE Rev.1.2 SANKEN ELECTRIC CO., LTD. Feb. 28, 2022 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2016 9 SUK3015 Physical Dimensions ● TO220S-2L Package (1.4) 4.44 ±0.2 (5) 1.3 ±0.2 (1.2) 9.1 ±0.3 +0.3 10.5 -0.5 (0.45) Gate burr +0.2 0.86 -0.1 +0.2 1.34 -0.1 A 2.54 ±0.1 0.4 ±0.1 2.54 ±0.1 Dimensions between roots Dimensions between roots 2.6 ±0.2 Dimensions between roots 10.2 ±0.3 1.5 ±0.3 +0.2 0.1 -0.1 0.3 0.3 Plane Buck side (S=2/1) +0.3 3 -0.5 (5.4) 3 1.4±0.2 2 (1.3) 1 0~8° Enlargement of A (S=10/1) NOTES: - Dimensions in millimeters Maximum gate burr height is 0.3mm. Bare lead frame: Pb-free (RoHS compliant) Moisture Sensitivity Level 3 (MSL 3) When soldering the products, it is required to minimize the working time within the following limits: Reflow: Preheat: 150 °C to 200 °C / 60 s to 120 s Solder heating: 240 °C / 30s, 3 times (245 °C peak) Soldering Iron: 350 °C / 3.5 s, 1 time Marking Diagram SUK3015 YM DD SK Part Number Lot Number Y is the last digit of the year of manufacture (0 to 9) M is the month of the year (1 to 9, O, N or D) DD is the day of the month (01 to 31) SUK3015-DSE Rev.1.2 SANKEN ELECTRIC CO., LTD. Feb. 28, 2022 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2016 10 SUK3015 Important Notes ● All data, illustrations, graphs, tables and any other information included in this document (the “Information”) as to Sanken’s products listed herein (the “Sanken Products”) are current as of the date this document is issued. The Information is subject to any change without notice due to improvement of the Sanken Products, etc. Please make sure to confirm with a Sanken sales representative that the contents set forth in this document reflect the latest revisions before use. ● The Sanken Products are intended for use as components of electronic equipment or apparatus (transportation equipment and its control systems, home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the Sanken Products, please put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken. If considering use of the Sanken Products for any applications that require higher reliability (traffic signal control systems or equipment, disaster/crime alarm systems, etc.), you must contact a Sanken sales representative to discuss the suitability of such use and put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken, prior to the use of the Sanken Products. The Sanken Products are not intended for use in any applications that require extremely high reliability such as: aerospace equipment; nuclear power control systems; and medical equipment or systems, whose failure or malfunction may result in death or serious injury to people, i.e., medical devices in Class III or a higher class as defined by relevant laws of Japan (collectively, the “Specific Applications”). Sanken assumes no liability or responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, resulting from the use of the Sanken Products in the Specific Applications or in manner not in compliance with the instructions set forth herein. ● In the event of using the Sanken Products by either (i) combining other products or materials or both therewith or (ii) physically, chemically or otherwise processing or treating or both the same, you must duly consider all possible risks that may result from all such uses in advance and proceed therewith at your own responsibility. ● Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the occurrence of any failure or defect or both in semiconductor products at a certain rate. You must take, at your own responsibility, preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which the Sanken Products are used, upon due consideration of a failure occurrence rate and derating, etc., in order not to cause any human injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products. Please refer to the relevant specification documents and Sanken’s official website in relation to derating. ● No anti-radioactive ray design has been adopted for the Sanken Products. ● The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples, all information and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of use of the Sanken Products. ● Sanken assumes no responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, or any possible infringement of any and all property rights including intellectual property rights and any other rights of you, users or any third party, resulting from the Information. ● No information in this document can be transcribed or copied or both without Sanken’s prior written consent. ● Regarding the Information, no license, express, implied or otherwise, is granted hereby under any intellectual property rights and any other rights of Sanken. ● Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied, including, without limitation, any warranty (i) as to the quality or performance of the Sanken Products (such as implied warranty of merchantability, and implied warranty of fitness for a particular purpose or special environment), (ii) that any Sanken Product is delivered free of claims of third parties by way of infringement or the like, (iii) that may arise from course of performance, course of dealing or usage of trade, and (iv) as to the Information (including its accuracy, usefulness, and reliability). ● In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and regulations that regulate the inclusion or use or both of any particular controlled substances, including, but not limited to, the EU RoHS Directive, so as to be in strict compliance with such applicable laws and regulations. ● You must not use the Sanken Products or the Information for the purpose of any military applications or use, including but not limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Information, or providing them for non-residents, you must comply with all applicable export control laws and regulations in each country including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan, and follow the procedures required by such applicable laws and regulations. ● Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including the falling thereof, out of Sanken’s distribution network. ● Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting from any possible errors or omissions in connection with the Information. ● Please refer to our official website in relation to general instructions and directions for using the Sanken Products, and refer to the relevant specification documents in relation to particular precautions when using the Sanken Products. ● All rights and title in and to any specific trademark or tradename belong to Sanken and such original right holder(s). DSGN-AEZ-16003 SUK3015-DSE Rev.1.2 SANKEN ELECTRIC CO., LTD. Feb. 28, 2022 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2016 11
SUK3015 价格&库存

很抱歉,暂时无法提供与“SUK3015”相匹配的价格&库存,您可以联系我们找货

免费人工找货