DC
DC Fan
DC Fan 40 mm sq.
40×40×28 mm
San Ace 40 9GV type
■ General Specifications
· Material……………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0)
· Expected life………………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage)
Expected life at 40°C is for reference only.
· Motor protection function………………… Locked rotor burnout protection, Reverse polarity protection
For details, please refer to p. 599.
· Dielectric strength………………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
· Insulation resistance……………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
· Sound pressure level (SPL)……………… At 1 m away from the air inlet
· Storage temperature……………………… -20 to +70˚C (Non-condensing)
· Lead wire……………………………………
Red
Black or Blue
Yellow
Sensor
· Mass………………………………………… 50 g
■ Specifications
The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers.
Model no.
Rated voltage
Operating voltage range
Rated current
Rated input
Rated speed
SPL
Operating temperature
Expected life
[V]
[V]
[A]
[W]
[min-1]
[m3/min]
[CFM]
[Pa]
[inchH2O]
[dB (A)]
[˚C]
[h]
10.8 to 12.6
0.84
0.6
0.47
0.31
0.15
10.08
7.2
5.64
3.72
1.8
16500
14700
13000
11600
8300
0.76
0.68
0.6
0.53
0.37
26.8
24.0
21.1
18.7
13.1
415
330
260
207
100
1.668
1.325
1.044
0.831
0.402
58
55
52
49
41
-20 to +60
40000/60˚C
(70000/40˚C)
9GV0412K301
9GV0412J301
9GV0412G301
9GV0412H301
9GV0412C301
12
7 to 13.2
Max. airflow
Max. static pressure
-20 to +70
Note: Sensor and control options are available for selection. Refer to the table on p. 632.
■ Airflow - Static Pressure Characteristics
9GV0412K301
9GV0412J301
With pulse sensor
Operating voltage range
Operating voltage range
1.6
400
1.4
350
1.2
300
1.0
250
0.8
200
0.6
150
0.4
100
0.2
50
0.25
0
0
1.75
12.6 V
1.50
12 V
10.8 V
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min)
0
5
10 15
20
Airflow
25
30
(CFM)
1.25
1.50
400
350
13.2 V
300
1.00
250
0.75
200
0.50
(inch H2O) (Pa)
450
Static pressure
450
With pulse sensor
Operating voltage range
(inch H2O) (Pa)
1.8
Static pressure
Static pressure
(inch H2O) (Pa)
0
9GV0412G301
With pulse sensor
12 V
150
7V
100
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min)
0
5
10
15
Airflow
20
25
30 (CFM)
350
1.25
300
1.00
250
0.75
200
0.50
0.25
50
400
0
13.2 V
12 V
7V
150
100
50
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m3/min)
0
5
10
15
20
25
30
(CFM)
Airflow
CATALOG No. C1111B002 '21.9.IT
51
9GV0412H301
9GV0412C301
With pulse sensor
Operating voltage range
(inch H2O) (Pa)
1.2 300
0.6
0.8 200
Static pressure
Static pressure
1.0 250
13.2 V
0.6 150
12 V
0.4 100
0.2
50
0
0
With pulse sensor
Operating voltage range
(inch H2O) (Pa)
7V
140
120
0.4
100
0.3
0.2
0
0.1 0.2 0.3 0.4 0.5 0.6 (m3/min)
160
0.5
0.1
0 2 4 6 8 10 12 14 16 18 20
(CFM)
13.2 V
80
12 V
60
40
7V
20
0
0.1 0.2 0.3 0.4 0.5 (m3/min)
0 2 4 6 8 10 12 14 16 (CFM)
Airflow
■ Dimensions (unit: mm)
Airflow
(With ribs)
40±0.3
4-ø3.5±0.3
Mounting hole
Lead wire
AWG26
UL 1007
+30
320 0
32±0.3
32±0.3
40±0.3
28±0.5
(4)
(4)
(10)
Airflow direction
Rotating direction
■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm)
Inlet side, Outlet side
39
39
4-ø3.7
(17.6)
(17.6)
32±0.3
32±0.3
40
DC
DC Fan 40 mm sq.
■ Airflow - Static Pressure Characteristics
■ Options
Finger guards
Model no.: 109-059, 109-059H
52
CATALOG No. C1111B002 '21.9.IT
page: p. 584