T9-817
Thermal (T- and TA-Line)
www.schurter.com /PG17_18_19
Circuit Breaker for Equipment thermal vertical, THT terminals for PCB mounting, 1 pole
Description
- Thermal circuit breaker
- 1-pole
- On request available with elevaled glow-wire ratings
- THT connectors
Unique Selling Proposition
- Reset type
- Cycling trip-free release
- Compact design
- Different mounting possibilities
- Designed for standard and medical applications
- Power supplies
- Uninterruptible power supply
- Power tools
- Industrial appliances
- HVAC
- Household appliances
Weblinks
pdf datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, DistributorStock-Check, Detailed request for product, Product News, Video
Standards
- Approval Reference Type: T9
- IEC 60934
- UL 1077
- CSA C22.2 No. 235
- GB 17701
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current
Conditional short circuit capacity
␣
Applications
240 V, 50 / 60 Hz
48 V
4-12 A
IEC: Inc, PC1, AC 240 V: 2 kA
UL / CSA: SC, AC 240 V DC 48 / 32 V:
2 kA, C1
Degree of protection front side IP 40
Endurance minimum
IEC: 200% Ir, cos φ 0.6: min. 50 switching cycles
Endurance typical
4-8 A: 150% Ir, cos φ 0.9:
2500 switching cycles
␣
10-12 A: 150% Ir, cos φ 0.9:
6000 switching cycles
Dielectric Strength
1500 VAC
Insulation Resistance
500 VDC > 1000 MΩ
Ambient temperature
␣
Soldering Methods
Solderability
Resistance to Soldering Heat
Weight
5-12 A: -5 °C to 60 °C
4 A: -5°C to 50 °C
Wave
245 °C / 3 sec acc. to IEC 60068-220 / Test Ta, method 1
260 °C / 10 sec acc. to IEC 60068-220 / Test Tb, method 1A
approx. 12.5 g
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in General Product
Information
Circuit Breakers
1
T9-817
Thermal (T- and TA-Line)
www.schurter.com /PG17_18_19
Dimension [mm]
Ø9.5
8
3.95 4.3
3.25
.25
10.75 8.25
1.25
36.1
Ø2
R1
4.3
5.5
8
19
12.2
7.8 6.8
0.8
6.3
4.1
10
0.4
Ø7.8
2.3
2
6.3
9.2
Approval
Rated current
Rated voltage AC
Rated voltage DC
UL 1077
4 - 12 A
240 V
48 V
CSA 22.2 235
4 - 12 A
240 V
48 V
IEC 60934
4 - 12 A
240 V
48 V
GB 17701
4 - 12 A
240 V
48 V
Typical internal resistance
Rated Current [A]
Internal Resistance [mΩ]
4
26.3
5
24.1
6
19.0
7
18.0
8
14.8
10
13.0
12
12.7
2
Circuit Breakers
T9-817
Thermal (T- and TA-Line)
www.schurter.com /PG17_18_19
Time-Current-Curves
[min]
[sec]
10'000
T9
5 A -16 A (TC-1)
60
4A
(TC-2)
30
20
1'000
10
5
Time in Seconds
3
100
1
10
1.35
1.45
0.1
1
1.05
1
2
3
4
5
6
7
8
10
Multiple of Rated Current In
Reference Temperature +23°
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient temperature [°C]
Correction factor
-5
0,85
+10
0,95
+23
1,00
+40
1,08
+60
1,21
Example: Rated current = 10 A; Environmental temperature = 60 °C; --> Correction factor
= 1.21; Resulting current = 12.1 A --> Fount to next higher rated current: 13 A
Variants
connection type
Rated current
Order Number
Solder, THT
4A
3-101-228
Solder, THT
5A
3-101-227
Solder, THT
6A
3-101-226
Solder, THT
7A
3-101-232
Solder, THT
8A
3-101-231
Solder, THT
10A
3-101-230
Solder, THT
12A
3-101-229
Availability for all products can be searched real-time:http://www.schurter.com/en/StockCheck/Stock-Check-SCHURTER
100 Pcs
08.06.2017
Packaging Unit
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Circuit Breakers
3
很抱歉,暂时无法提供与“3-101-227”相匹配的价格&库存,您可以联系我们找货
免费人工找货