T9-817
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
Circuit Breaker for Equipment thermal vertical, THT terminals for PCB mounting, 1 pole
See below:
Approvals and Compliances
Description
- Thermal circuit breaker
- 1-pole
- On request available with elevaled glow-wire ratings
- THT connectors
Unique Selling Proposition
- Reset type
- Cycling trip-free release
- Compact design
- Different mounting possibilities
- Power supplies
- Uninterruptible power supply
- Power tools
- Industrial appliances
- HVAC
- Household appliances
References
Weblinks
pdf data sheet, html datasheet, General Product Information, DistributorStock-Check, Detailed request for product, Product News, Video
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current
Conditional short circuit capacity Inc
Applications
240
48
4-12 A
IEC 60934: PC1, AC 240 V: 2 kA
UL / CSA: SC, AC 240 V DC 48 / 32 V:
2 kA, C1
Degree of protection front side IP40
Endurance minimum
IEC: 200% Ir, cos φ 0.6: min. 50 switching cycles
Endurance typical
4-8 A: 150% Ir, cos φ 0.9:
2500 switching cycles
␣
10-12 A: 150% Ir, cos φ 0.9:
6000 switching cycles
Dielectric Strength
1500 VAC
Insulation Resistance
500 VDC > 1000 MΩ
Allowable Operation Temp.
Soldering Methods
Solderability
Resistance to Soldering Heat
Weight
5-12 A: -5 °C to 60 °C
4 A: -5°C to 50 °C
Wave
245 °C / 3 sec acc. to IEC 60068-220 / Test Ta, method 1
260 °C / 10 sec acc. to IEC 60068-220 / Test Tb, method 1A
approx. 12.5 g
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.
Circuit Breakers
1
T9-817
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: T9
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
VDE Certificate Number: 40038016
UL Approvals
UL
UR File Number: E71572
CCC Approvals
CCC
CCC Certificate Number: 2020970307003348
Design
Standard
Description
Designed according to
IEC 60934
Circuit-breakers for equipment (CBE)
Designed according to
UL 1077
Standard for Supplementary Protectors for Use in Electrical Equipment
Designed according to
CSA C22.2 No. 235
Supplementary Protectors
Designed according to
GB 17701
Circuit-breaker for equipment
Design
Standard
Description
Suitable for applications acc.
IEC/UL 62368-1
Audio/video, information and communication technology equipment - Part
1: Safety requirements
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
UKCA declaration of conformity
SCHURTER AG
The UKCA marking declares that the product complies with the applicable
requirements laid down in the British Amendment of Regulation (EC)
765/2008.
RoHS
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Product standards
Product standards that are referenced
Organization
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
Dimension [mm]
Ø9.5
12.2
4.3
2.3
2
6.3
9.2
2
Circuit Breakers
Ø2
3.25
.25
8
10.75 8.25
36.1
1.25
0.8
7.8 6.8
5.5
8
19
6.3
4.1
10
0.4
Ø7.8
3.95 4.3
R1
T9-817
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
Approval
Rated current
Rated Voltage AC
Rated Voltage DC
UL 1077
4 - 12 A
240 V
48 V
CSA 22.2 235
4 - 12 A
240 V
48 V
IEC 60934
4 - 12 A
240 V
48 V
GB 17701
4 - 12 A
240 V
48 V
Typical internal resistance per pole
Rated Current [A]
Internal Resistance [mΩ]
4
26.3
5
24.1
6
19.0
7
18.0
8
14.8
10
13.0
12
12.7
Time-Current-Curves
[min]
[sec]
10'000
T9
5 A -16 A (TC-1)
60
4A
(TC-2)
30
20
1'000
10
5
Time in Seconds
3
100
1
10
1.35
1.45
0.1
1
1.05
1
2
3
4
5
6
7
8
10
Multiple of Rated Current In
Ambient temperature +23°
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient Temperature [°C]
Correction factor
-5
0,85
+10
0,95
+23
1,00
+40
1,08
+60
1,21
Example: Rated current = 10 A, Environmental temperature = 60 °C, --> Correction factor
= 1.21, Resulting current = 12.1 A --> Round to next higher rated current: 13 A
Circuit Breakers
3
T9-817
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
All Variants
Config. Code
Designation
Order Number
T9--0
T9, Circuit Breakers, , , , , ,
3-101-226
T9--0
T9, Circuit Breakers, , , , , ,
3-101-227
T9--0
T9, Circuit Breakers, , , , , ,
3-101-228
T9--0
T9, Circuit Breakers, , , , , ,
3-101-229
T9--0
T9, Circuit Breakers, , , , , ,
3-101-230
T9--0
T9, Circuit Breakers, , , , , ,
3-101-231
T9--0
T9, Circuit Breakers, , , , , ,
3-101-232
The listed variants should be available from stock. Other versions on request www.schurter.com/contact
Availability for all products can be searched real-time: https://www.schurter.com/en/info-center/support-tools/stock-check-distributors
100 Pcs
27.03.2024
Packaging Unit
4
Circuit Breakers
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each