DD14
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
IEC Appliance Inlet C14 with Filter 2-Stages, Fuseholder 1- or 2-pole, Line Switch 2-pole
Screw-on mounting horizontal (version B)
Order required accessories separately
Screw-on mounting vertical (version A)
Snap-in mounting
C14
See below:
Approvals and Compliances
70° C
Description
- Panel Mount :
Snap-in or screw-on mounting from front side
- 4 Functions :
Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for
fuse-links 5 x 20 mm 1‑ or 2‑pole , 2-Stages line filter in standard and
medical version
- V-Lock notch standard
- Quick connect terminals 6.3 x 0.8 mm
Unique Selling Proposition
- Most compact power entry module with 2-stages filter
- Attractive flat design
- Various mounting options
- V-Lock cord retaining
Characteristics
- Ultra-compact design. Ideal for low profile designs
Aluminum case provides good shielding
- All single elements are already wired
- Fuse drawer meets requirements of medical standard IEC/EN 60601-1
- Ideal for application with high transient loads
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
- Solder terminals
- Fuse drawer 1-pole, plus spare fuse case
- Fuse drawer 2-pole, with shorting bar
- Other rocker marking
- Line switch, illuminated
- Line switch 1-pole
- Medical version M80
- Class X1- and Y1-capacitors for enhanced withstand voltage
References
Alternative: version without line filter DD11
Weblinks
pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product, Microsite
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temperature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Material: Housing
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 8 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (1 min/50 Hz)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on mounting: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in version: 1 mm - 3 mm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
C14 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at higher
ambient temperature see derating curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 2'000'000 h acc. to MIL-HB-217 F
Approvals and Compliances
EMC Products
1
DD14
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 134485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: DD14
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40001522
UL Approvals
UL
UL File Number: E72928
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
IEC 60939
Passive filters for suppressing electromagnetic interference
Designed according to
IEC 60127-6
Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Designed according to
IEC 61058-1
Switches for appliances. Part 1. General requirements
Designed according to
UL 498
Standard for Attachment Plugs and Receptacles
Designed according to
UL 1283
Electromagnetic interference filters
Designed according to
CSA C22.2 no. 42
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Designed according to
CSA C22.2 no. 8
Electromagnetic interference (EMI) filters
Design
Standard
Description
Designed for applications acc.
IEC/UL 60950
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Designed for applications acc.
IEC 60601-1
Medical electrical equipment - Part 1: General requirements for basic
safety and essential performance
Designed for applications acc.
IEC 60335-1
Safety of electrical appliances for household and similar purposes. Meets
the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13.
Details
Initiator
Description
RoHS
SCHURTER AG
EU Directive RoHS 2011/65/EU
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
MicrositeV-Lock
SCHURTER AG
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
Medical Equipment
SCHURTER AG
Suitable for use in medical equipment according to IEC/UL 60601-1
Product standards
Product standards that are referenced
Organization
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
2
EMC Products
DD14
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Dimensions [mm]
Screw version A
56 ±0.15
0.
5
3.
5±
3.4
9.8
60
15.1
R
29.8
90°
±0.10
3.25
L
PE
12
N
31.5
56
66
3.
4/
M
3
49.3 ±0.10
5.9
1.3
Screw version B
5
3.
3
R
M
4/
3.
29.8 ±0.10
37 ±0.15
PE
N
12
37
47
L
±0
.5
90°
3.25
49.3 ±0.10
9.8
51
3.4
60
15.1
5.9
1.3
EMC Products
3
DD14
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Snap-in mounting from front side
49.3 ±0.10
9.8
15.1
61.5
1.3
4.4
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances
L [mH]
Capacitance
CX [nF]
Capacity
Cy1 [nF]
Capacity
Cy2 [nF]
R [MΩ]
1
Standard Version
2 x 10
220
1.5
1
1
2
Standard Version
2x4
220
1.5
1
1
4
Standard Version
2 x 1.5
220
1.5
1
1
6
Standard Version
2 x 0.8
220
1.5
1
1
8
Standard Version
2 x 0.6
220
1.5
1
1
10
Standard Version
2 x 0.3
220
1.5
1
1
1
Medical Version (M5)
2 x 10
220
-
-
1
2
Medical Version (M5)
2x4
220
-
-
1
4
Medical Version (M5)
2 x 1.5
220
-
-
1
6
Medical Version (M5)
2 x 0.8
220
-
-
1
8
Medical Version (M5)
2 x 0.6
220
-
-
1
10
Medical Version (M5)
2 x 0.3
220
-
-
1
4
EMC Products
5±
3.
R
29.5 ±0.10
12
N
PE
32.5
L
0.
5
52
DD14
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Diagrams
Standard version
N
Standard version
illuminated
F2
L1
1) PE
Cy1
R
Cx
F1
L
L2
Cx
Cy1
N
N’
L1
Cy2
L2
Cy2
PE’ 2)
F2
L1
Cy1
1) PE
L’
L
R
1) Line
2) Load
Medical version (M5)
Medical version M5
illuminated
F2
L1
1) PE
R
Cx
F1
L
Cx
L2
N
N’
L1
PE’ 2)
L2
L
1) Line
2) Load
L2
F2
1) PE
L’
Cx
F1
1) Line
2) Load
N
N’
L1
Cy1
L1
R
F1
Cx
Cx
L2
L2
L1
Cx
Cy2
PE’ 2)
Cy2
L’
N’
PE’ 2)
L2
L’
1) Line
2) Load
Derating Curves
2-pole
2.0
1.5
I = 1.0 In
I = 0.7 In
1.0
I =
很抱歉,暂时无法提供与“3-104-203”相匹配的价格&库存,您可以联系我们找货
免费人工找货