0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3-104-203

3-104-203

  • 厂商:

    SCHURTER

  • 封装:

  • 描述:

    SCHURTER - 3-104-203 - Filtered IEC Power Entry Module, 2 A, 250 VAC

  • 数据手册
  • 价格&库存
3-104-203 数据手册
DD14 Power Entry Modules with Line Filter https://www.schurter.com /PG06 IEC Appliance Inlet C14 with Filter 2-Stages, Fuseholder 1- or 2-pole, Line Switch 2-pole Screw-on mounting horizontal (version B) Order required accessories separately Screw-on mounting vertical (version A) Snap-in mounting C14 See below: Approvals and Compliances 70° C Description - Panel Mount : Snap-in or screw-on mounting from front side - 4 Functions : Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for fuse-links 5 x 20 mm 1‑ or 2‑pole , 2-Stages line filter in standard and medical version - V-Lock notch standard - Quick connect terminals 6.3 x 0.8 mm Unique Selling Proposition - Most compact power entry module with 2-stages filter - Attractive flat design - Various mounting options - V-Lock cord retaining Characteristics - Ultra-compact design. Ideal for low profile designs Aluminum case provides good shielding - All single elements are already wired - Fuse drawer meets requirements of medical standard IEC/EN 60601-1 - Ideal for application with high transient loads - Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request - Solder terminals - Fuse drawer 1-pole, plus spare fuse case - Fuse drawer 2-pole, with shorting bar - Other rocker marking - Line switch, illuminated - Line switch 1-pole - Medical version M80 - Class X1- and Y1-capacitors for enhanced withstand voltage References Alternative: version without line filter   DD11  Weblinks pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product, Microsite Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Panel Thickness S Material: Housing   1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz 1 - 8 A @ Ta 40 °C / 250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (1 min/50 Hz) -25 °C to 85 °C 25/085/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on mounting: max 8 mm Mounting screw torque max 0.5 Nm Snap-in version: 1 mm - 3 mm Thermoplastic, black, UL 94V-0 appliance inlet/-outlet Fuseholder Rated Power Acceptance @ Ta 23 °C Power Acceptance @ Ta > 23°C Line Switch Line Filter MTBF C14 acc. to IEC 60320-1 UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm 5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole Admissible power acceptance at higher ambient temperature see derating curves Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 2'000'000 h acc. to MIL-HB-217 F Approvals and Compliances EMC Products 1 DD14 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in   Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 134485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: DD14 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40001522 UL Approvals UL UL File Number: E72928 Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13. Details Initiator Description RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. MicrositeV-Lock SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 Product standards Product standards that are referenced Organization Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification 2 EMC Products DD14 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Dimensions [mm] Screw version A 56 ±0.15 0. 5 3. 5± 3.4 9.8 60 15.1 R 29.8 90° ±0.10 3.25 L PE 12 N 31.5 56 66 3. 4/ M 3 49.3 ±0.10 5.9 1.3 Screw version B 5 3. 3 R M 4/ 3. 29.8 ±0.10 37 ±0.15 PE N 12 37 47 L ±0 .5 90° 3.25 49.3 ±0.10 9.8 51 3.4 60 15.1 5.9 1.3 EMC Products 3 DD14 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Snap-in mounting from front side 49.3 ±0.10 9.8 15.1 61.5 1.3 4.4 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacity Cy1 [nF] Capacity Cy2 [nF] R [MΩ] 1 Standard Version 2 x 10 220 1.5 1 1 2 Standard Version 2x4 220 1.5 1 1 4 Standard Version 2 x 1.5 220 1.5 1 1 6 Standard Version 2 x 0.8 220 1.5 1 1 8 Standard Version 2 x 0.6 220 1.5 1 1 10 Standard Version 2 x 0.3 220 1.5 1 1 1 Medical Version (M5) 2 x 10 220 - - 1 2 Medical Version (M5) 2x4 220 - - 1 4 Medical Version (M5) 2 x 1.5 220 - - 1 6 Medical Version (M5) 2 x 0.8 220 - - 1 8 Medical Version (M5) 2 x 0.6 220 - - 1 10 Medical Version (M5) 2 x 0.3 220 - - 1 4 EMC Products 5± 3. R 29.5 ±0.10 12 N PE 32.5 L 0. 5 52 DD14 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Diagrams Standard version N Standard version illuminated F2 L1 1) PE Cy1 R Cx F1 L L2 Cx Cy1 N N’ L1 Cy2 L2 Cy2 PE’ 2) F2 L1 Cy1 1) PE L’ L R 1) Line 2) Load Medical version (M5) Medical version M5 illuminated F2 L1 1) PE R Cx F1 L Cx L2 N N’ L1 PE’ 2) L2 L 1) Line 2) Load L2 F2 1) PE L’ Cx F1 1) Line 2) Load N N’ L1 Cy1 L1 R F1 Cx Cx L2 L2 L1 Cx Cy2 PE’ 2) Cy2 L’ N’ PE’ 2) L2 L’ 1) Line 2) Load Derating Curves 2-pole 2.0 1.5 I = 1.0 In I = 0.7 In 1.0 I =
3-104-203 价格&库存

很抱歉,暂时无法提供与“3-104-203”相匹配的价格&库存,您可以联系我们找货

免费人工找货