DG11
Power entry modules without line filter
https://www.schurter.com /PG05
IEC Appliance Inlet C14 or C18 with Circuit Breaker TA35 2-pole
Screw-on with IP67 and TA35 in white with black
printed symbols
C14
Screw-on with IP67
Snap-in IP40 with TA35 red illuminated and embossed symbols
C18
See below:
Approvals and Compliances
70° C
70° C
Description
- Panel mount :
Screw-on version from front or rear side, snap-in version from front
side
- 2 Functions :
Appliance Inlet , protection class I or II , Circuit breaker type TA35
, 2-pole
- Pre-wired coupling
- V-Lock notch standard
- Quick connect terminal 6.3 x 0.8 mm
Unique Selling Proposition
- Variant tested for IP67 into the appliance
- Various mounting options
- Recessed rocker prevents accidental manipulation
- Compatible with V-Lock cord retention
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temperature
IP-Protection
Insulation cover
Terminal
Panel Thickness S
Material: Housing
Characteristics
- Connector and circuit breaker are prewired
- Circuit Breaker non-illuminated or illuminated
- Suitable for use in equipment according to IEC/UL 60950
Other versions on request
- Version without pre-wiring from inlet to circuit breaker
- Protection class II, 70°C
- Variants in white
References
Substitute for type 6135
Component: circuit breakers TA35 Rocker 2Pole
Weblinks
pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product, Microsite
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 60 °C
from front side IP40 or IP67 acc. to IEC
60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Recommended torque min 0.25 Nm
Snap-in : S =1/1.2/1.5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
Circuit Breakers
C14 / C18 acc. to IEC 60320-1
UL 60320-1, CSA C22.2 no. 60320-1
(for cold conditions) pin-temperature 70
°C, 10 A, Protection Class I or II
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or nonilluminated.
Conditional short circuit Inc:
2000 A
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
Connectors
1
DG11
Power entry modules without line filter
https://www.schurter.com /PG05
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: DG11
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40048151
UL Approvals
UL
UL File Number: E96454
CQC Approvals
CQC
CCC Certificate Number: pending
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
UL 60320-1
Standard for Attachment Plugs and Receptacles
Designed according to
CSA C22.2 no. 60320-1
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Design
Standard
Description
Designed for applications acc.
IEC/UL 60950
IEC 60950-1 includes the basic requirements for the safety of information
technology equipment.
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS
SCHURTER AG
EU Directive RoHS 2011/65/EU
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
MicrositeV-Lock
SCHURTER AG
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
Product standards
Product standards that are referenced
Organization
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
Dimensions [mm]
Snap-in mounting for front mount IP40
(51.6)
35
5.65
48.3
30 ±0.10
22.1
63
59 +0.20
0
16
5.35
R1.5
x.
ma
+0.10
0
S
32.45
S = Panel thickness
2
Connectors
3.3
R3
DG11
Power entry modules without line filter
https://www.schurter.com /PG05
Screw-on mounting version A for front mount IP40
5.65
(51.6)
30
+0.20
0
22.1
ø 6.2
ø 3.4
35
±0.10
59
66
76
16
R
5.35
3.3
±0.10
48.3
66
1.5
max.
R3
ø 3.4/M3
1.2
32.45
Screw-on mounting Version A for rear mount IP40
(51.6)
5.65
50.1
59.2
±0.10
±0.10
22.1
57.2
66
76
16
R
5.35
±0.10
1.5
66
ø 3.4
1
.R
ax
1.8
35
34.25
ø 3.4/M3
m
1.5
Screw-on mounting Version B for front mount IP40
5.65
48.3
30
±0.10
16
22.1
59
63
1.2
±0.10
ø 3.4 / M3
ø 6.2
5.35
38
+0.20
0
(51.6)
48
x
ma
3.3
3
32.45
.R
.5
R1
38
Connectors
3
DG11
Power entry modules without line filter
https://www.schurter.com /PG05
Screw-on mounting version B for rear mount IP40
5.65
(51.6)
38 ±0.10
5.35
29.2 ±0.10
57.2 ±0.10
22.1
63
16
ø 3.4
50.1
ø 3.4 / M3
48
m
R1
ax
.R
1.8
.5
38
34.25
1
1.5
Screw-on mounting for front mount IP67
(53.6)
5.65
±0.10
22.1
38
68
38
+0.20
34.3 ±0.10
16
5.35
59 0
50.3
ø 3.4/M3
51
L
L' P1
2)
PE
PE'
TA35
1)
N
N' P2
1) Line
2) Load
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient Temperature [°C]
Correction factor
-30
0.76
-20
0.81
0
0.90
+23
1.00
+40
1.03
+50
1.04
+60
1.06
Example: Rated current = 5 A, Environmental temperature = 50 °C --> Correction factor =
1.04, Resulting current = 5.2 A --> Fount to next higher rated current: 6 A
4
Connectors
3
Diagrams
42 ±0.10
.R
3.3
ax
m
32.45
42
DG11
Power entry modules without line filter
https://www.schurter.com /PG05
Time-Current-Curves
[ min ] [ sec ]
10'000
60
30
20
10
[ min ] [ sec ]
10'000
Typ
p
TA35
3–15A (TC-1, TC-2)
5
200
1
Typ
Nennstrom
Umgebungstemp.
60
50
20
10
100
1
50
20
10
5
5
2
2
1
1
0,5
0,5
0,3
0,3
0,2
0,2
0,1
0,1
1,05 1,35
2
3
4
5
8
10
1,05 1,35
Multiple of Rated Current In
Multiple of Rated Current In
Reference Temperature +23°
Reference Temperature +23°
2
3
Connectors
4
5
8
10
5
DG11
Power entry modules without line filter
https://www.schurter.com /PG05
ORDER CODE
Table 1 Selection for type TA35
Switch
Switch
1
2
LINE
LINE
LOAD
LOAD
CBT
without
illumination
illuminated
Order example
2-pole
Number of switched poles
Number of protected poles
C32
C34
Colours
W
B
3
4
6
Rocker
black
black
black
black
black
non-illuminated
illuminated
white
black
–
–
–
–
–
red transparent
green transparent
orange transparent
Other colours on request
Rocker legend
0
K
printed
L
printed
l
M printed
OFF OFF
printed
white
0
l
H
Colour of print
white
0
embossed
l
F
ON
Illustration
ON
Surface
black
black
Other legends on request
Position of the rocker
legend e.g. I / O
Rated current In (A)
In
Code
In
Code
1,0
2,0
4,0
5,0
6,0
J10
J20
040
050
060
8,0
10,0
12,0
15,0
080
100
120*
150*
Other rated currents on request
6
Connectors
W
F
120
C0
No other
features
Other versions on request
Switch front
CBD
CBD
C12
C14
240 V
120 V
TA35-
*) UL / CSA only
DG11
Power entry modules without line filter
https://www.schurter.com /PG05
Configuration Code
Typ
DG11
Configuration Code
(Example) TA35
C B D W F 1 2 0 C 0 -000- C6135-X X X - X X X -00
see table 1
Please note that Schurter will establish an
internal part number for logistics use in addition
to the order code. The format of this internal
part number is, for example: 3-XXX-XXX
Color
0
Black
Panel Mounting
1)
00
Screw version A front mounting
01
Screw version B front mounting
02
Screw version A rear mounting
03
Screw version B rear mounting
10
Snap-in 1.0 mm
12
Snap-in 1.2 mm
15
Snap-in 1.5 mm
20
Snap-in 2.0 mm
25
Snap-in 2.5 mm
30
Snap-in 3.0 mm
88
Screw version front mounting
(sealed towards housing, IP65)
Terminal PE
0
Without (PCII)
1
QC 6.3x0.8 mm
Terminal N
1
QC 6.3x0.8 mm (unwired)
3
Connection to TA35 (wired)
Terminal L
1
QC 6.3x0.8 mm (unwired)
3
Connection to TA35 (wired)
1)
Screw version A
Screw version B
All Variants
Config. Code
Order Number
DG11-C126F100C0-000-C6135-331-200-00
3-107-924
█
DG11-CBDWM100C0-000-C6135-331-880-00
3-108-454
█
DG11-CBDBL100C0-000-C6135-331-010-00
3-108-463
█
DG11-CBDWM100C0-000-C6135-331-150-00
3-109-713
█
DG11-CBDWM100C0-000-C6135-331-010-00
3-109-714
█
DG11-CBDWM100C0-000-C6135-331-020-00
3-109-715
█
DG11-CBDWM150C0-000-C6135-331-150-00
3-109-716
█
DG11-CBDWM150C0-000-C6135-331-010-00
3-109-717
█
DG11-CBDWM150C0-000-C6135-331-020-00
3-109-718
█
DG11-CBDWM150C0-000-C6135-331-880-00
3-109-719
█
█ Most Popular.
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
10 Pcs
23.07.2018
Packaging unit
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Connectors
7