4782
Cord Connectors (Rewireable)
https://www.schurter.com /PG07
IEC Connector C13, Rewireable, Straight
C13
See below:
Approvals and Compliances
70° C
Description
References
- Cord Connectors (Rewireable)
- Screw-on mounting
- Available in black, grey and white
- Pin temperature 70 °C
- Protection class I
Substitute for type 4020; 4022
Weblinks
pdf data sheet, html datasheet, General Product Information, Approvals,
Distributor-Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temperature
Protection against electric
shock
Terminal
Material: Housing
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 2 kVAC between L-N
> 2 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
Appliance inlet/-outlet
C13 acc. to IEC 60320-1
UL 60320-1, CSA C22.2 no. 60320-1
(for cold conditions) pin-temperature 70
°C, 10 A, Protection Class I
Suitable for appliances with protection
class I acc. to IEC 61140
Cable
Thermoplastic, black / grey / white, UL
94V-0
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: 4782
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40031778
UL Approvals
UL
UL File Number:
CCC Approvals
CCC
CCC Certificate Number: 2019180204012088
METI Approvals
METI
Japan Electrical Safety and Environment technology Laboratories
Connectors
1
4782
Cord Connectors (Rewireable)
https://www.schurter.com /PG07
Product standards
Product standards that are referenced
Organization
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
UL 60320-1
Standard for Attachment Plugs and Receptacles
Designed according to
CSA C22.2 no. 60320-1
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Design
Standard
Description
Suitable for applications acc.
IEC/UL 62368-1
Audio/video, information and communication technology equipment - Part
1: Safety requirements
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
UKCA declaration of conformity
SCHURTER AG
The UKCA marking declares that the product complies with the applicable
requirements laid down in the British Amendment of Regulation (EC)
765/2008.
RoHS
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
Halogen Free
SCHURTER AG
SCHURTER strives to offer our customers halogen free products.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
Dimensions [mm]
4782
62
28.7
21
87.5
All Variants
Color
Recommended cable diameter
Max. wire size (IEC)
Max. wire size (UL)
Order Number
grey
8.5 mm
3 x 1 mm²
3 x 18 AWG
3-122-694
grey
10 mm
3 x 1.5 mm²
3 x 14 AWG
3-122-695
white
8.5 mm
3 x 1 mm²
3 x 18 AWG
3-122-698
white
10 mm
3 x 1.5 mm²
3 x 14 AWG
3-122-699
black
8.5 mm
3 x 1 mm²
3 x 18 AWG
4782.0000
█
black
10 mm
3 x 1.5 mm²
3 x 14 AWG
4782.0100
█
█ Most Popular.
Availability for all products can be searched real-time: https://www.schurter.com/en/info-center/support-tools/stock-check-distributors
Max. torque for screws: Terminals: 0.5 Nm, Cable clamps: 0.3 Nm, Cover: 0.3 Nm
2
Connectors
4782
Cord Connectors (Rewireable)
https://www.schurter.com /PG07
Accessories
Description
Cord_retaining_kits
Cord retaining strain relief
Mating Inlets/Plugs
Category / Description
» Overview complete
IEC Appliance Inlet C14 with Line Switch 1-pole
KEB1
IEC Appliance Inlet C14, with Line Switch 2-pole, Voltage Selector and Fuseholder 1or 2-pole
6766
IEC Appliance Inlet C14 with Line Switch 1- or 2-pole
6010-K
IEC Appliance Inlet C14 with Fuseholder 2-pole, Line Switch 2-pole and Voltage Selector
GRM1
IEC Appliance Inlet C14 with Appliance Outlet F, Line Switch 2-pole and Voltage Selector
PMM
...
Appliance Inlet Overview complete
6061, Mounting: Screw, Appliance Inlet: IEC C14
6080
6110-3, Mounting: Screw, Solder / Quick Connect, Appliance Inlet: IEC C16
6110-3
6110-4, Mounting: Snap-in, Solder / Quick Connect, Appliance Inlet: IEC C16
6110-4
6100-3, Mounting: Screw, Solder / Quick Connect, Appliance Inlet: IEC C14
6100-3
6100-4, Mounting: Snap-in, Solder / Quick Connect, Appliance Inlet: IEC C14
6100-4
...
Distribution Unit Overview complete
0712-PQ, Mounting: Snap-in, Front Side, Solder terminal (4.8 x 0.8 mm), 1x Appliance Outlet: IEC F
0712
4741, Mounting: 2x Appliance Outlet: IEC F
4741
4747, Mounting: 4x Appliance Outlet: IEC F
4747
4740, Mounting: 6x Appliance Outlet: IEC F
4740
IEC Inlet Filter Overview complete
GRF2, Mounting: Rear Side, With EMC-shield and without line filter, 10 A, Plug Connector, Appliance Inlet: IEC C14,
Suitable for appliances with protection class I
GRF2
5110, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Thermoplastic
Appliance Inlet: IEC C14, prewired, Suitable for appliances with protection class I
5110
KFS, Mounting: Screw, Front Side, Filter: Standard version, Without fuse holder: 10 A, Appliance Inlet: IEC C14, prewired
KFS
Plug Overview complete
4732, Mounting: Power Cord, Plug: IEC E, Cable
4732
4735, Mounting: Power Cord, Plug: IEC E, Cable
4735
9009, Mounting: Plug: IEC E, Screw clamps
9009
4733, Mounting: Power Cord, Plug: IEC E, Cable
4733
4736, Mounting: Power Cord, Plug: IEC E, Cable
4736
...
Connectors
3
4782
Cord Connectors (Rewireable)
https://www.schurter.com /PG07
Category / Description
Power Entry Module Overview complete
DF11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 6.3 x 0.8
mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I or II 0 DF11,
Mounting:Screw, Quick connect terminals 6.3 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I or II 0 DF11,
Power Entry ModuleC14, 55°C, version: L: N: ground: : fuseholder: color: design: dimension S: features: 0 DF11, Moun- DF11
ting: Snap-in/screw-on, Appliance Inlet: IEC C14, Without fuse holder: : black, Suitable for appliances with protection
class I or II 0 DF11, Mounting: Snap-in/screw-on8 mm, Quick connect terminals 6.3 x 0.8 mm, IP40,: black, Appliance
Inlet: IEC C14, Circuit Breakers TA45, A, non-illuminated, Protection Class I or II 0 DF11, Mounting: Snap-in/screw-on,
mm, Without fuse holder: : IEC Suitable for appliances with protection class I or II 0
DD11, Mounting: Screw-on mounting, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals
4.8 x 0.8 mm, Appliance Inlet: IEC C14, With or without protection cover, Fuseholder: 1-/2-pole, Suitable for appliances DD11
with protection class I
DD21, Mounting: Screw-on mounting Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, additional quick
DD21
connect 4.8 x 0.8 mm Appliance Inlet: IEC C14, Fuseholder: 1-/2-pole
DC11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 1-/2-pole, Quick connect terminals 4.8 x 0.8
mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I or II
DC11
KEB2, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or
illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I
KEB2
...
Power Entry Module with line filter Overview complete
DG12, Mounting : Screw, 8 mm, 15 A, prewired, Standard and Medical Version, Appliance Inlet: IEC C14 C18, Circuit
Breakers TA35: DG12, Suitable for appliances with protection class I or II
DG12
DD14, Mounting: Screw-on mounting, Front Side, Filter, Standard and Medical Version, Fuseholder:1-/2-pole, 10 A,
Rocker switch: 2-pole, non-illuminated Appliance Inlet: IEC C14, prewired
DD14
DD12, Mounting: Screw-on mounting, Front Side, Filter, Standard and Medical Version, Fuseholder:1-/2-pole, 10 A,
Rocker switch: 2-pole, non-illuminated Appliance Inlet: IEC C14, prewired
DD12
KFB1, Mounting: Screw, Front Side, Filter: Standard version, Without fuse holder: 10 A, Rocker switch: 1-pole, Appliance Inlet: IEC C14, prewired
KFB1
KFB2, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Rocker switch:
2-pole, Appliance Inlet: IEC C14, prewired
KFB2
28.03.2024
...
4
Connectors
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.