3-123-522

3-123-522

  • 厂商:

    SCHURTER

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
3-123-522 数据手册
FMBB EP 1-Phase Line Filters https://www.schurter.com /PG84 AC Filter 2-Stage, excellent Attenuation Case ME Case MB Case MF See below: Approvals and Compliances Description - Line filter in standard and medical version - 2 stage - Compact design - Very light due to partial potting Unique Selling Proposition - Excellent differential and common-mode attenuation - Broad band attenuation - Completely closed steel housing - Wide temperature range Characteristics - Designed for current applications of 1 - 36 A - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - Especially designed for industrial applications such as: Frequency Converters, Stepper Motor Drives, UPS-Systems, Inverters - Suitable for use in equipment according to IEC/UL 62368-1 Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP) References Alternative: High attenuation version   FMBB NEO  Weblinks pdf data sheet, html datasheet, General Product Information, Approvals, Distributor-Stock-Check, Detailed request for product, Microsite Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Material   1 - 36 A @ Ta 40 °C / 250 VAC; 50 Hz 1 - 36 A @ Ta 40 °C / 125/250 VAC; 60 Hz standard < 0.5 mA (250 V / 50 Hz) medical (M5) < 5 µA resp. (M80) < 80 µA (250 V / 50 Hz) 1.7 kVDC between L-N 2.7 kVDC between L/N-PE Test voltage (2 sec) -40 °C to 100 °C Line Filter MTBF Standard and Medical Version, IEC 60939, UL 60939-3, CSA C22.2 no. 8 Technical Details > 200'000 h acc. to MIL-HB-217 F 40/100/21 acc. to IEC 60068-1 rear-side IP20 IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminal 6.3 x 0.8 mm Bolt and nut M4 Nickel plated steel Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. EMC Products 1 FMBB EP 1-Phase Line Filters https://www.schurter.com /PG84 Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: FMBB EP Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40051449 UL Approvals UL UR File Number: E495089 Design Standard Description Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to UL 60939-3 Passive filters for suppressing electromagnetic interference Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Design Standard Description Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements Suitable for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. UKCA declaration of conformity SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP) Product standards Product standards that are referenced Organization Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification 2 EMC Products FMBB EP 1-Phase Line Filters https://www.schurter.com /PG84 Dimension [mm] Case 09 with quick connect terminals max. 77 max. 46 max. 52 17.5 7.5 12 max. 31 27 6.3x0.8 (5x) 4.8 ±0.3 (2x) 60.4 ±0.5 1) 2) 1) Line 2) Load Case MB with bolt and nut M4 max. 160 27 max. 58 max. 131 15.2 12 5) 13 max. 46 4) max. 156 144 ±0.5 140 ±0.5 1) 2) M4 (4x) 4) 5.3 ±0.3 (2x) 3) 1) Line 2) Load 3) Nut torque 0.8...1 Nm, keep lock-nut fastened 4) Lock-nut do not unscrew 5) PE: M4x16, 1.2...1.5 Nm, keep lock-nut fastened EMC Products 3 FMBB EP 1-Phase Line Filters https://www.schurter.com /PG84 Case MC with quick connect terminals max. 51 max. 66 21 6 12 max. 31 27 max. 90 75 ±0.5 5.3 ±0.3 (2x) 6.3x0.8 (5x) 1) 2) 1) Line 2) Load Case UB with quick connect terminals max. 51 max. 66 11.4 12 max.41 27 max. 90 75 ±0.5 5.3 ±0.3 (2x) 6.3x0.8 (5x) 1) 1) Line 2) Load 4 EMC Products 2) 10.4 FMBB EP 1-Phase Line Filters https://www.schurter.com /PG84 Case ME with quick connect terminals max. 52 max. 112 27 12 12 max. 46 13 max. 87 max. 115 104.5 ±0.5 97.5 ±0.5 5.3 ±0.3 (2x) 6.3x0.8 (5x) 1) 2) 1) Line 2) Load Case MF with bolt and nut M4 max. 85 max. 98 40 16 max. 59 max. 130 max. 120 109 ±0.3 4.4 ±0.3 (4x) 3) 2) 54.5 ±0.5 1) M4 (4x) 4) 47.5 ±0.5 5) 1) Line 2) Load 3) Nut torque 0.8...1 Nm, keep lock-nut fastened 4) Lock-nut do not unscrew 5) PE: M4x16, 1.2...1.5 Nm, keep lock-nut fastened EMC Products 5 FMBB EP 1-Phase Line Filters https://www.schurter.com /PG84 Diagrams Standard and low leakage current Medical M5 1) 2) 1) 2) 1) Line, 2) Load Medical M80 1) 2) 1) Line, 2) Load Attenuation Loss. . . . . 0.1/100Ω differential mode ........... 100/0.1Ω differential mode - - - - 50Ω differential mode _____ 50Ω common mode Standard version 1A 3A 6A 10 A 12 A 16 A 20 A 30 A 36 A 6 EMC Products FMBB EP 1-Phase Line Filters https://www.schurter.com /PG84 Medical version (M5) 1A 3A 6A 10 A 12 A 16 A 20 A 30 A 1A 3A 6A 10 A 12 A 16 A 20 A 30 A 36 A Medical version (M80) 36 A EMC Products 7 FMBB EP 1-Phase Line Filters https://www.schurter.com /PG84 Low leakage current version 1A 3A 6A 10 A 12 A 16 A 20 A 30 A 36 A All Variants Rated current Filter-Type Terminal [A] 1 Standard version Quick connect terminal 6.3 x 0.8 mm Leakage Ri Power Loss Weight Housing Packaging Order Number [mA] [mΩ] [W] [g] 1.47 600 1.2 125 g 09 15 3-123-509 [ST] 3 Standard version Quick connect terminal 6.3 x 0.8 mm 1.47 168 3 128 g 09 15 3-123-510 6 Standard version Quick connect terminal 6.3 x 0.8 mm 1.47 40 2.88 133 g 09 15 3-123-511 10 Standard version Quick connect terminal 6.3 x 0.8 mm 6.91 8.6 4.4 198 g MC 10 3-123-522 12 Standard version Quick connect terminal 6.3 x 0.8 mm 3.14 6.2 4.15 201 g MC 10 3-123-523 █ 16 Standard version Quick connect terminal 6.3 x 0.8 mm 3.14 8.0 4.1 265 g UB 10 3-123-524 █ 20 Standard version Quick connect terminal 6.3 x 0.8 mm 3.14 6 4.8 390 g ME 5 3-123-525 █ 30 Standard version Bolt and nut M4 3.14 6 10.8 855 g MF 3 3-123-526 36 Standard version Bolt and nut M4 3.14 4.2 10.4 890 g MB 4 3-123-527 1 Low leakage current Quick connect terminal 6.3 x 0.8 mm 0.15 600 1.2 125 g 09 15 3-123-537 3 Low leakage current Quick connect terminal 6.3 x 0.8 mm 0.15 168 3 128 g 09 15 3-123-538 6 Low leakage current Quick connect terminal 6.3 x 0.8 mm 0.15 40 2.88 133 g 09 15 3-123-539 10 Low leakage current Quick connect terminal 6.3 x 0.8 mm 0.15 8.6 4.4 198 g MC 10 3-123-540 12 Low leakage current Quick connect terminal 6.3 x 0.8 mm 0.15 6.2 4.15 201 g MC 10 3-123-541 16 Low leakage current Quick connect terminal 6.3 x 0.8 mm 0.15 8.0 4.1 265 g UB 10 3-123-542 20 Low leakage current Quick connect terminal 6.3 x 0.8 mm 0.15 6 4.8 390 g ME 5 3-123-543 30 Low leakage current Bolt and nut M4 0.15 6 10.8 855 g MF 3 3-123-544 36 Low leakage current Bolt and nut M4 0.15 4.2 10.4 890 g MB 4 3-123-545 1 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 0.005 600 1.2 125 g 09 15 3-123-528 3 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 0.005 168 3 128 g 09 15 3-123-529 6 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 0.005 40 2.88 133 g 09 15 3-123-530 10 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 0.005 8.6 4.4 198 g MC 10 3-123-531 12 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 0.005 6.2 4.15 201 g MC 10 3-123-532 16 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 0.005 8.0 4.1 265 g UB 10 3-123-533 20 Medical Version (M5) Quick connect terminal 6.3 x 0.8 mm 0.005 6 4.8 390 g ME 5 3-123-534 8 EMC Products FMBB EP 1-Phase Line Filters https://www.schurter.com /PG84 Rated current Filter-Type Terminal [A] Leakage Ri Power Loss Weight [mA] [mΩ] [W] [g] Housing Packaging Order Number [ST] 30 Medical Version (M5) Bolt and nut M4 0.005 6 10.8 855 g MF 3 36 Medical Version (M5) Bolt and nut M4 0.005 4.2 10.4 890 g MB 4 3-123-535 3-123-536 1 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 0.073 600 1.2 125 g 09 15 3-142-126 3 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 0.073 168 3 128 g 09 15 3-142-127 6 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 0.073 40 2.88 133 g 09 15 3-142-128 10 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 0.073 8.6 4.4 198 g MC 10 3-142-129 12 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 0.073 6.2 4.15 201 g MC 10 3-142-130 16 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 0.073 8.0 4.1 265 g UB 10 3-142-131 20 Medical Version (M80) Quick connect terminal 6.3 x 0.8 mm 0.073 6 4.8 390 g ME 5 3-142-132 30 Medical Version (M80) Bolt and nut M4 0.073 6 10.8 855 g MF 3 3-142-133 36 Medical Version (M80) Bolt and nut M4 0.073 4.2 10.4 890 g MB 4 3-142-134 █ Most Popular. Availability for all products can be searched real-time: https://www.schurter.com/en/info-center/support-tools/stock-check-distributors Leakage current according IEC 60939-1 20A, 30A and 36A medical filter M5 and M80, are only suitable for medical equipment intended for permanently connection to the mains. Accessories Description DIN_Rail_Kit Mounting accessory for compact 1- and 3-phase filters 28.03.2024   The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. EMC Products 9
3-123-522 价格&库存

很抱歉,暂时无法提供与“3-123-522”相匹配的价格&库存,您可以联系我们找货

免费人工找货
3-123-522

    库存:0