C20F
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
IEC Appliance Inlet C20 with Filter, Front or Rear Side Mounting
Screw-on mounting
from front side
Snap-in mounting
from front side
C20
See below:
Approvals and Compliances
70° C
Description
- Panel mount :
Screw-on version from front or rear side, snap-in version front side
- 2 Functions :
Appliance Inlet Protection class I , Line filter in standard and medical
version
- Solder / quick connect / wires (stranded)
Unique Selling Proposition
- Attractive flat front design
- Highly resistant since fully potted
- Interrupts ground loops
- V-Lock cord retaining
Characteristics
- Compact design with optimal shielding
Suitable for assembly in metal plated plastic housings
- Version with class X1 and X2 (standard version) capacitors
- Universal line filter for standard applications
- Suitable for use in medical equipment according to IEC/UL 60601-1 (1
MOOP, 1 MOPP)
For applications according IEC/UL 62368-1 we recommend variants
with bleed resistor
Other versions on request
- 16A according to UL
- Capacity CX 330 nF
References
Alternative: version without line filter 4793; 4798
Weblinks
pdf data sheet, html datasheet, General Product Information, Approvals,
Distributor-Stock-Check, Accessories, Detailed request for product
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Impulse Withstand Voltage
Allowable Operation Temperature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Material
16 A @ Ta 40 °C / 250 VAC; 50 Hz
20 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
> 2.5 kV between L-N (CX2)
> 4 kV between L-N (CX1)
> 5 kV between L/N-PE (Cy2)
voltage (1.2/50 μs)
-25 °C to 85 °C
Appliance inlet/-outlet
Line Filter
MTBF
C20 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection Class I
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 3'000'000 h acc. to MIL-HB-217 F
25/085/21 acc. to IEC 60068-1
front side IP40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Solder / quick connect / wires (stranded)
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1 mm to 3 mm
Thermoplastic, black, UL 94V-0
Approvals and Compliances
EMC Products
1
C20F
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: C20F
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
VDE Certificate Number: 104884
UL Approvals
UL
UR File Number: E72928
CQC Approvals
CQC
CQC Certificate Number: CQC18001191999
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
IEC 60939
Passive filters for suppressing electromagnetic interference
Designed according to
IEC 61058-1
Switches for appliances. Part 1. General requirements
Designed according to
UL 498
Standard for Attachment Plugs and Receptacles
Designed according to
UL 1283
Passive filters for suppressing electromagnetic interference
Designed according to
CSA C22.2 no. 42
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Designed according to
CSA C22.2 no. 8
Electromagnetic interference (EMI) filters
Design
Standard
Description
Suitable for applications acc.
IEC/UL 62368-1
Audio/video, information and communication technology equipment - Part
1: Safety requirements
Suitable for applications acc.
IEC 60601-1
Medical electrical equipment - Part 1: General requirements for basic
safety and essential performance
Product standards
Product standards that are referenced
Organization
Application standards
Application standards where the product can be used
Organization
2
EMC Products
C20F
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Compliances
The product complies with following Guide Lines
Identification
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
UKCA declaration of conformity
SCHURTER AG
The UKCA marking declares that the product complies with the applicable
requirements laid down in the British Amendment of Regulation (EC)
765/2008.
RoHS
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
SCHURTER AG
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
SCHURTER AG
Suitable for use in medical equipment according to IEC/UL 60601-1 (1
MOOP, 1 MOPP)
Medical Equipment
Dimension [mm]
Screw-on from front side
10.7
R6
6.3 x 0.8 *
3.5/M3
64.65
30
42 ±0.15
34.8 +0.20
0
ø 6.3x95°
33.90
x 25.90
53
42
3.5
9.4
R3
3.85
26.8
+0.20
0
79.2
* Solder terminal: identical outer dimensions
Screw-on mounting from rear side with metal flange
10.7
R6
6.3 x 0.8 *
3
3.5
max. R 0.5
M3
28
64.65
30
79.2
42 ±0.15
33.90
x 25.90
53
42
36
36.4 +0.20
0
9.4
R 0.5
3.85
EMC Products
28.3
+0.20
0
3
C20F
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Snap-in mounting from front side
10.7
38
33.90
x 25.85
34.8 +0.20
0
9.4
R2
64.65
30
R3
3.85
26.3
+0.20
0
79.2
Screw-on mounting from front side with flexible wire
7
±2
150
+10
0
Technical Data of Filter-Components
Rated Current [A]
4
Filter-Type
Inductance L1/
L2 [mH]
Inductance L3
[mH]
Capacitance CX
[nF]
Capacitance CY
[nF]
R [MΩ]
16
Standard version
2 x 0.3
-
100
2.2
1
16
Standard Version with Ground Line Choke
2 x 0.3
0.15
330
2.2
1
16
Medical Version (M5)
2 x 0.3
-
100
-
1
16
Medical Version (M80)
2 x 0.3
-
100
0.47
1
16
Medical Version (M5) with Ground Line Choke
2 x 0.3
0.15
330
-
1
EMC Products
C20F
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Diagrams
Standard version
Medical Version (M5)
L
L’
L
L’
L1
1) PE
Cx
L1
Cy
R
L2
N
PE’ 2)
Cy
1) PE
N’
Cx
PE’ 2)
R
L2
N
N’
1) Line
2) Load
1) Line
2) Load
Standard version with ground line choke
Medical Version (M5) with ground line choke
L
L’
L1
1)
PE
Cx
N
1) Line
2) Load
Attenuation Loss
Cy
R
L2
L3
Cy
2)
PE’
N’
L
L’
L1
1)
PE
Cx
2)
PE’
R
L2
N’
N
L3
1) Line
2) Load
- - - - 50Ω differential mode _____ 50Ω common mode
Standard version
20 A
Medical version (M5)
20 A
Standard with Earth Line Choke
20A
EMC Products
5
C20F
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Medical (M5) with Earth Line Choke
20A
All Variants
Rated Current
IEC [A]
Rated Current Filter-Type
UL [A]
Panel mounting
Mounting side
Terminal
Capacitor
V-Lock
Order Number
16
20
Standard version
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
mm
X2 100nF
l
C20F.0111
16
20
Standard version
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
mm
X1 100nF
l
C20F.0113
16
20
Standard version
Snap-in
Front Side
Solder terminals
X2 100nF
l
C20F.0011
16
20
Standard version
Snap-in
Front Side
Solder terminals
X1 100nF
l
C20F.0013
16
20
Standard version
Screw
Rear Side
Flexible wire AWG14
X2 100nF
l
C20F.0221
16
20
Standard version
Screw
Rear Side
Flexible wire AWG14
X1 100nF
l
C20F.0223
16
20
Standard version
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
mm
X2 100nF
l
C20F.0121
16
20
Standard version
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
mm
X1 100nF
l
C20F.0123
16
20
Standard version
Screw
Rear Side
Solder terminals
X2 100nF
l
C20F.0021
16
20
Standard version
Screw
Rear Side
Solder terminals
X1 100nF
l
C20F.0023
16
20
Standard version
Screw
Front Side
Quick connect terminals 6.3 x 0.8
mm
X2 100nF
l
C20F.0101
16
20
Standard version
Screw
Front Side
Quick connect terminals 6.3 x 0.8
mm
X1 100nF
l
C20F.0103
16
20
Standard version
Screw
Front Side
Solder terminals
X2 100nF
l
C20F.0001
16
20
Standard version
Screw
Front Side
Solder terminals
X1 100nF
l
C20F.0003
16
20
Standard Version with
Ground Line Choke
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
mm
X2 330nF
l
3-124-295
16
20
Standard Version with
Ground Line Choke
Screw
Front Side
Quick connect terminals 6.3 x 0.8
mm
X2 330nF
l
3-124-273
16
20
Medical Version (M5)
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
mm
X2 100nF
l
C20F.0112
16
20
Medical Version (M5)
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
mm
X1 100nF
l
C20F.0114
16
20
Medical Version (M5)
Snap-in
Front Side
Solder terminals
X2 100nF
l
C20F.0012
16
20
Medical Version (M5)
Snap-in
Front Side
Solder terminals
X1 100nF
l
C20F.0014
16
20
Medical Version (M5)
Screw
Rear Side
Flexible wire AWG14
X2 100nF
l
C20F.0022
16
20
Medical Version (M5)
Screw
Rear Side
Flexible wire AWG14
X2 100nF
l
C20F.0222
16
20
Medical Version (M5)
Screw
Rear Side
Flexible wire AWG14
X1 100nF
l
C20F.0024
16
20
Medical Version (M5)
Screw
Rear Side
Flexible wire AWG14
X1 100nF
l
C20F.0224
16
20
Medical Version (M5)
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
mm
X2 100nF
l
C20F.0122
16
20
Medical Version (M5)
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
mm
X1 100nF
l
C20F.0124
16
20
Medical Version (M5)
Screw
Front Side
Quick connect terminals 6.3 x 0.8
mm
X2 100nF
l
C20F.0102
16
20
Medical Version (M5)
Screw
Front Side
Quick connect terminals 6.3 x 0.8
mm
X1 100nF
l
C20F.0104
16
20
Medical Version (M5)
Screw
Front Side
Solder terminals
X2 100nF
l
C20F.0002
16
20
Medical Version (M5)
Screw
Front Side
Solder terminals
X1 100nF
l
C20F.0004
16
20
Medical Version (M5) with
Ground Line Choke
Screw
Front Side
Quick connect terminals 6.3 x 0.8
mm
X2 330nF
l
3-124-294
6
EMC Products
█
█
█
█
█
C20F
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Rated Current
IEC [A]
Rated Current Filter-Type
UL [A]
Panel mounting
Mounting side
Terminal
Capacitor
V-Lock
Order Number
█ Most Popular.
Availability for all products can be searched real-time: https://www.schurter.com/en/info-center/support-tools/stock-check-distributors
Wire length: 150 mm
Packaging unit
20 Pcs
Accessories
Description
Wire_Harness
Wire harness for SCHURTER products
Assorted_Covers
Rear Cover
0859.0047
RC320
Rear Cover for Power Entry Module
Cord_retaining_kits
Cord retaining strain relief
Countersunk, K
4700.0010
Flat head, L
4700.0011
EMC Products
7
C20F
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Mating Outlets/Connectors
Category / Description
Connector Overview complete
4795, Mounting: Power Cord, Cable Connector: IEC C19
4795
4790, Mounting: Power Cord, Screw Connector: IEC C19
4790
0104U, Mounting: Power Supply Cord, Screw clamps Connector: IEC C19
0104U
Mating Outlets/Connectors shuttered
Power Cord Overview complete
VAC19KS, Overview, V-Lock cord retaining, diverse Connector IEC C19, diverse, black
VAC19KS
28.03.2024
8
EMC Products
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.