TA36 Rocker
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
Circuit Breaker for Equipment thermal, Rocker actuation, 2 pole
1-pole
Rocker red
Flange black
1-pole
Rocker green
Flange white
2-pole
Rocker black
Flange black
See below:
Approvals and Compliances
Description
- Thermal circuit breaker
- 1-/2 pole
- Snap-in version
- Positively trip-free release
- Method of operation acc. to IEC: S-type
- Different rocker and flange colours
- Wide current range
Unique Selling Proposition
Applications
- Power tools
- Medical and laboratory equipment
- Industrial appliances
- Equipment for construction
- Cleaning equipment
- Commercial and household kitchen appliances
- Industrial Power
- Industrial lighting arrays
- Unique UL rating of 277 VAC
- Finely graded rated currents
- High configurability (rocker colours, lettering)
- Appealing design
Weblinks
Technical Data
Rated Voltage AC
Overload
IEC: 240 VAC
UL/CSA : 277 VAC
Rated Voltage DC
1-pole: 32 VDC / 2-pole: 60 VDC
Rated current range AC
0.05 - 20 A
Conditional short circuit capa- IEC 60934: 0.05...20 A: 2 kA, SC (C1)
city Inc
@ 240 VAC
Degree of Protection
front side IP40 acc. to IEC 60529
Dielectric Strength
50 Hz: > 2.5 kV
Impulse 1.2/50 μs: > 4 kV
Insulation Resistance
500 VDC > 100 MΩ
Lifetime
mechanical: 50'000 switching cycles
␣
AC: 1 x Ir, cos φ 0.6:
50'000 switching cycles
␣
DC: 1 x Ir, L/R = 2 - 3 ms:
50'000 switching cycles
pdf data sheet, html datasheet, General Product Information, DistributorStock-Check, Detailed request for product, Product News
␣
Allowable Operation Temp.
Vibration Resistance
Shock Resistance
Tripping Type
Actuation Type
Weight
IEC: min. 40 trips
@ 6 x Ir, cos φ 0.6
UL / CSA: min. 50 trips
@ 1.5 x Ir, cos φ 0.75
-30 °C to 60 °C
± 0.75 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Tc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Tc
30 G / 18 ms
acc. to IEC 60068-2-27, test Ea
Thermal
Rocker
1-pole 19 g - 2-pole 32 g
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.
Circuit Breakers
1
TA36 Rocker
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: TA36
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
VDE Certificate Number: 40019754
UL Approvals
UL
UL File Number: E71572
CCC Approvals
CCC
CCC Certificate Number: pending
Design
Standard
Description
Designed according to
IEC 60934
Circuit-breakers for equipment (CBE)
Designed according to
UL 1077
Standard for Supplementary Protectors for Use in Electrical Equipment
Designed according to
CSA C22.2 No. 235
Supplementary Protectors
Designed according to
GB 17701
Circuit-breaker for equipment
Design
Standard
Description
Designed for applications acc.
IEC/UL 62368-1
IEC 62368-1 includes the basic requirements for safety of audio, video,
information technology and office equipment.
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Product standards
Product standards that are referenced
Organization
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
2
Circuit Breakers
TA36 Rocker
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
Dimension [mm]
29
20.7
36
44.1
10.6
10.6
51.7
33.5
51.7
44.1
33.5
1.9
1.9
18
9.7
2.3
12.5
2.3
23.5
21.3
21.3
26
33.8
14.5
33.8
Quick connect terminal
IEC 61210 A6,3-0.8
Quick connect terminal
IEC 61210 A6,3 - 0,8
1-pole
2-pole
Panel cut-out
Panel cut-out
2 Pole
14.5
+0.2
0
26
+0.2
0
+0.2
0
+0.2
0
34
34
+0.3
Panel 1.0 − 3.5 mm
Panel 1.0 − 3.5 mm
Diagrams
1-pole, 1 bimetal, non illuminated
1)
2-pole, 1 bimetal, non illuminated
P1
P1
1)
2-pole, 2 bimetal, non illuminated
P1
P2
1)
P2
4
2)
4
2)
1) Line, 2) Load
Codepos AAA = CFT, CGT
Approval
4
8
1) Line, 2) Load
2)
5
1) Line, 2) Load
Rated current
Rated Voltage AC
Rated Voltage DC
UL 1077
0.05...20 A
277 V
32/60 V
CSA C22.2
235
0.05...20 A
277 V
32/60 V
IEC 60934
0.05...20 A
240 V
32/60 V
Circuit Breakers
3
TA36 Rocker
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
Typical internal resistance per pole
Rated Current [A]
Internal Resistance [Ω]
0.05
200.0000
0.1
70.0000
0.2
18.8000
0.3
8.6500
0.4
4.4000
0.5
2.7500
0.8
0.9100
1.0
0.7200
1.2
0.5000
1.5
0.3400
2.0
0.1870
2.5
0.1150
3.0
0.0590
3.5
0.0590
4.0
0.0590
5.0
0.0440
6.0
0.0280
7.0
0.0142
8.0
0.0142
10.0
0.0109
12.0
0.0086
13.0
0.0072
14.0
0.0072
15.0
0.0056
16.0
0.0056
18.0
0.0052
20.0
0.0052
Time-Current-Curves
Tripping Characteristics In < 3 A
Tripping Characteristics In 3 -20 A
[min] [sec ]
10'000
[min] [sec ]
10'000
TA35
60
30
20
10
TA35
3-20A (TC-1, TC-2)
(3 pole
max. 12A)
60
3 pole
Circuit Breakers
2
3
4
5
8
10
TA36 Rocker
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature,
use a correction factor (typical value) from the table below:
Ambient Temperature [°C]
Correction factor
1-pole
2-pole
-30
0.77
0.76
-20
0.81
0.81
0
0.90
0.90
+23
1.00
1.00
+40
1.03
1.03
+50
1.04
1.04
+60
1.06
1.06
Example: Rated current = 5 A, Environmental temperature = 50 °C --> Correction factor = 1.04, Resulting current = 5.2 A --> Fount to
next higher rated current: 6 A
Circuit Breakers
5
TA36 Rocker
6
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
Circuit Breakers
TA36 Rocker
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
All Variants
Basic function
Rocker
Marking
Front bezel
Rated Current [A]
Config. Code
Order Number
1 pole, 1 bimetal
white
I/O; embossed
black
20
TA36-RS14FQ100BWHE200000-000
3-125-263
1 pole, 1 bimetal
white
I/O; embossed
grey
20
TA36-RS14FQ100GWHE200000-000
3-128-204
1 pole, 1 bimetal
green
I/O; embossed
black
20
TA36-RS14FQ100BGHE200000-000
3-128-208
1 pole, 1 bimetal
black
ON/OFF; white
black
16
TA36-RS14FQ100BBFW160000-000
3-128-211
1 pole, 1 bimetal
black
I/O; white
black
16
TA36-RS14FQ100BBHW160000-000
3-128-212
1 pole, 1 bimetal
black
I/O; embossed
black
10
TA36-RS14FQ100BBHE100000-000
3-128-197
1 pole, 1 bimetal
yellow
I/O; black
black
10
TA36-RS14FQ100BYHB100000-000
3-128-198
1 pole, 1 bimetal
black
I/O; embossed
black
6
TA36-RS14FQ100BBHE060000-000
3-128-199
1 pole, 1 bimetal
green
ON/OFF; white
white
5
TA36-RS14FQ100WGFW050000-000
3-128-213
1 pole, 1 bimetal
red
I/O; black
black
5
TA36-RS14FQ100BRHB050000-000
3-128-200
1 pole, 1 bimetal
white
I/O; embossed
black
3
TA36-RS14FQ100BWHE030000-000
3-128-201
2 pole, 2 bimetal
black
I/O; white
black
20
TA36-RS24FQ200BBHW200000-000
3-128-214
2 pole, 2 bimetal
black
I/O; white
grey
20
TA36-RS24FQ200GBHW200000-000
3-128-215
2 pole, 2 bimetal
green
I/O; embossed
black
20
TA36-RS24FQ200BGHE200000-000
3-128-216
2 pole, 2 bimetal
white
I/O; black
black
20
TA36-RS24FQ200BWHB200000-000
3-128-240
2 pole, 2 bimetal
black
ON/OFF; white
black
16
TA36-RS24FQ200BBFW160000-000
3-128-230
2 pole, 2 bimetal
black
I/O; white
black
16
TA36-RS24FQ200BBHW160000-000
3-128-231
2 pole, 2 bimetal
white
I/O; embossed
black
15
TA36-RS24FQ200BWHE150000-000
3-128-217
2 pole, 2 bimetal
white
I/O; black
black
15
TA36-RS24FQ200BWHB150000-000
3-128-218
2 pole, 2 bimetal
black
I/O; white
black
10
TA36-RS24FQ200BBHW100000-000
3-128-327
2 pole, 2 bimetal
black
I/O; embossed
black
10
TA36-RS24FQ200BBHE100000-000
3-128-232
2 pole, 2 bimetal
white
I/O; embossed
black
10
TA36-RS24FQ200BWHE100000-000
3-128-233
2 pole, 2 bimetal
green
I/O; white
white
10
TA36-RS24FQ200BGHW100000-000
3-128-234
2 pole, 2 bimetal
black
I/O; white
white
10
TA36-RS24FQ200WBHW100000-000
3-128-235
2 pole, 2 bimetal
white
I/O; black
white
10
TA36-RS24FQ200WWHB100000-000
3-128-219
2 pole, 2 bimetal
white
I/O; embossed
black
6
TA36-RS24FQ200BWHE060000-000
3-128-236
2 pole, 2 bimetal
white
I/O; embossed
black
5
TA36-RS24FQ200BWHE050000-000
3-128-221
2 pole, 2 bimetal
green
I/O; embossed
black
3
TA36-RS24FQ200BGHE030000-000
3-128-238
2 pole, 2 bimetal
black
I/O; embossed
black
3
TA36-RS24FQ200BBHE030000-000
3-128-239
2 pole, 2 bimetal
black
I/O; white
black
3
TA36-RS24FQ200BBHW030000-000
3-128-243
2 pole, 2 bimetal
white
I/O; black
black
3
TA36-RS24FQ200BWHB030000-000
3-128-244
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
1-pole
2-pole
20 pcs.
10 pcs.
08.03.2021
Packaging Unit
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Circuit Breakers