3404.0113.11

3404.0113.11

  • 厂商:

    SCHURTER

  • 封装:

    SMD,7.4x3.1mm

  • 描述:

    一次性保险丝(熔断) 750mA 125V

  • 数据手册
  • 价格&库存
3404.0113.11 数据手册
OMT 125 Fuses https://www.schurter.com /PG01_2 Surface Mount Fuse, 7.4 x 3.1 mm, Time-Lag T, 125 VAC, 125 VDC Exemplary part photo depending on part no. See below: UL 248-14 · 125 VAC · 125 VDC · Time-Lag T Approvals and Compliances Description References - Directly solderable on printed circuit boards Corresponding Fuseholder   Assembled Fuseholder   Weblinks pdf data sheet, html datasheet, General Product Information, DistributorStock-Check, Detailed request for product Technical Data   Rated Voltage Rated current Breaking Capacity Characteristic Mounting Admissible Ambient Temp. Climatic Category Material: Housing Material: Terminals Unit Weight Storage Conditions Product Marking 125 VAC, 125 VDC 0.25 - 6.3 A 100 A Time-Lag T PCB,SMT -40 °C to +85 °C 40/085/21 acc. to IEC 60068-1 Thermoplastic, UL 94V-0 Copper alloy, tin-plated 0.01 g 0 °C to 40 °C, max. 70% r.h. , Type, Rated current, Certification marks Soldering Methods Solderability Resistance to Soldering Heat Moisture Sensitivity Level Case Resistance Moisture Resistance Test Mechanical Shock Resistance to Solvents Terminal Strength Reflow, Wave Soldering Profile 245 °C / 3 sec acc. to IEC 60068-2-58, Test Td 260 +0/-5 °C / 40 sec acc. to IPC/JEDEC J-STD-020D, Level 1 MSL 1, J-STD-020  acc. to EIA/IS-722, Test 4.7 >100 MΩ (between leeds and body) MIL-STD-202, Method 106 (50 cycles in a temp./mister chamber) MIL-STD-202, Method 213 Condition A MIL-STD-202, Method 215 MIL-STD-202, Method 211A (Deflection of board 1 mm for 1 minute) Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: OMT 125 Approval Logo Certificates Certification Body Description UL Approvals UL UL File Number: E41599 Design Standard Description Designed according to UL 248-14 Low voltage fuses - Part 14: Supplemental fuses Designed according to CSA22.2 No. 248.14 Low-Voltage Fuses - Part 14: Supplemental Fuses Product standards Product standards that are referenced Organization Circuit Protection 1 OMT 125 Fuses https://www.schurter.com /PG01_2 Application standards Application standards where the product can be used Organization Design Standard Description Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. UKCA declaration of conformity SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Compliances The product complies with following Guide Lines Identification Dimension [mm]  7.4 mm   2.8 7.4 3.1 5.8 2.6 3 4 1.6 1.6 2 Soldering pads Pre-Arcing Time Rated Current In 1.0 x In min. 2.0 x In max. 8.0 x In min. 0.25 A - 0.375 A 4h 60 s 2 ms 30 ms 0.5 A - 6.3 A 4h 60 s 5 ms 100 ms 2 8.0 x In max. Circuit Protection 3.5 OMT 125 Fuses https://www.schurter.com /PG01_2 Time-Current-Curves 100000 ≤ 0.375 A _> 0.5 A 10000 1000 Time in Seconds 100 10 1 0.1 0.01 0.001 10 1 Multiple of Rated Current In All Variants Rated Current [A] Rated Voltage [VAC] Rated Voltage [VDC] 0.25 125 125 Breaking Capacity 1) Voltage Drop 1.0 In typ. [mV] Power Dissipation 1.0 In typ. [mW] Melting I²t 8.0 In typ. [A²s] 142 35.5 0.02 Order Number l 3404.0110.11 0.25 125 125 1) 142 35.5 0.02 l 3404.0110.22 0.25 125 125 1) 142 35.5 0.02 l 3404.0110.24 █ 0.375 125 125 1) 123 46.1 0.054 l 3404.0111.11 0.375 125 125 1) 123 46.1 0.054 l 3404.0111.22 0.375 125 125 1) 123 46.1 0.054 l 3404.0111.24 0.5 125 125 1) 95 47.5 0.16 l 3404.0112.11 █ 0.5 125 125 1) 95 47.5 0.16 l 3404.0112.22 █ 0.5 125 125 1) 95 47.5 0.16 l 3404.0112.24 0.75 125 125 1) 92 69 0.43 l 3404.0113.11 █ 0.75 125 125 1) 92 69 0.43 l 3404.0113.22 █ 0.75 125 125 1) 92 69 0.43 l 3404.0113.24 1 125 125 1) 88 88 0.77 l 3404.0114.11 █ 1 125 125 1) 88 88 0.77 l 3404.0114.22 █ 1 125 125 1) 88 88 0.77 l 3404.0114.24 1.5 125 125 1) 82 123 1.73 l 3404.0115.11 █ 1.5 125 125 1) 82 123 1.73 l 3404.0115.22 █ 1.5 125 125 1) 82 123 1.73 l 3404.0115.24 2 125 125 1) 75 150 3.58 l 3404.0116.11 █ 2 125 125 1) 75 150 3.58 l 3404.0116.22 █ 2 125 125 1) 75 150 3.58 l 3404.0116.24 2.5 125 125 1) 137 343 5.6 l 3404.0117.11 █ 2.5 125 125 1) 137 343 5.6 l 3404.0117.22 █ 2.5 125 125 1) 137 343 5.6 l 3404.0117.24 3 125 125 1) 128 384 8.06 l 3404.0118.11 █ 3 125 125 1) 128 384 8.06 l 3404.0118.22 █ 3 125 125 1) 128 384 8.06 l 3404.0118.24 3.5 125 125 1) 119 417 11.76 l 3404.0119.11 Circuit Protection 3 OMT 125 Fuses https://www.schurter.com /PG01_2 Rated Current [A] Rated Voltage [VAC] Rated Voltage [VDC] 3.5 125 125 3.5 125 4 125 4 125 4 Breaking Capacity Voltage Drop 1.0 In typ. [mV] Power Dissipation 1.0 In typ. [mW] Melting I²t 8.0 In typ. [A²s] 1) 119 417 11.76 l 125 1) 119 417 11.76 l 3404.0119.24 125 1) 77 308 12.3 l 3404.0120.11 █ 125 1) 77 308 12.3 l 3404.0120.22 █ 125 125 1) 77 308 12.3 l 3404.0120.24 5 125 125 1) 79 395 20.8 l 3404.0121.11 █ 5 125 125 1) 79 395 20.8 l 3404.0121.22 █ Order Number 3404.0119.22 5 125 125 1) 79 395 20.8 l 3404.0121.24 6.3 125 125 1) 82 516 25.4 l 3404.0122.11 6.3 125 125 1) 82 516 25.4 l 3404.0122.22 6.3 125 125 1) 82 516 25.4 l 3404.0122.24 █ Most Popular. Availability for all products can be searched real-time: https://www.schurter.com/en/info-center/support-tools/stock-checkdistributors 1) 100 A @ 125 VAC / 100 A @ 125 VDC Packaging Unit   .xx = .11 .xx = .22 .xx = .24 100 St. in ESD-plastic bag 750 pcs. in tape [W: 16mm and P1: 8mm] on reel [A: 18cm] 3000 pcs. in tape [W: 16mm and P1: 8mm] on reel [A: 33cm] 26.03.2024 acc. IEC 60286-3 Type 2a 4 Circuit Protection The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.
3404.0113.11 价格&库存

很抱歉,暂时无法提供与“3404.0113.11”相匹配的价格&库存,您可以联系我们找货

免费人工找货