Non resettable fuses www.schurter.com/pg0_2 Surface Mount Fuse for Space Application, ESCC QPL Listed
MGA-S
125 VAC · 125 VDC · Super-Quick-Acting FF
Description Standards
- ESCC QPL Listed, see www.escies.org - Full data sheet available on request - ESCC Generic Specification no. 4008 - ESCC Detail Specification no. 4008/001
Applications References Weblinks
- Protection of Payloads General Product Information Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check, Accessories, Product Change Notification (PCN)
Technical Data
Rated Voltage Rated Current Breaking Capacity Characteristic Mounting Admissible Ambient Air Temp. Climatic Category Material: Housing Material: Terminals Unit Weight Storage Conditions Product Marking 32 - 125 VAC, 125 VDC 0.14 - 3.5 A 50 A - 300 A Super-Quick-Acting FF PCB,SMT -55 °C to 150 °C 55/150/21 acc. to IEC 60068-1 Ceramic Tin-Plated Copper Alloy (with lead) 0.035 g 0 °C to 60 °C, max. 70% r.h. none 3.2 mm Soldering Methods Solderability Resistance to Soldering Heat Reflow, Wave 245 °C / 3 sec acc. to IEC 60068-2-58, Test Td 260 +0/-5 °C / 30 sec acc. to IPC/JEDEC J-STD-020D, Level 1
Dimensions
1.55
0.5 3.2
1.55
1.5
1.1
Soldering pads
Pre-Arcing Time
Rated Current In 0.14 A - 3.5 A .43 x In min. 4 h 3.58 x In min. 2 ms 3.58 x In max. 5 s 5.7 x In min. 500 us 5.7 x In max. 10 ms 8.57 x In min. 50 us 8.57 x In max. 2 ms
Fuses
2
MGA-S
www.schurter.com/pg0_2 Variants
Rated Current [A] Rated Voltage [VAC] Rated Voltage [VDC] Breaking Capacity Voltage Drop .0 In typ. [mV] 258 250 165 150 100 124 105 98 90 88 83.5 90 Cold Resistance typ. [mΩ] 1020 800 361 247 115 98.7 56 39 29.5 24.1 17 13.5 Melting I²t 4.0 In typ. [A²s] ESCC Component Number Order Number
Non resettable fuses
0.14 0.175 0.262 0.35 0.525 0.7 1.05 1.4 1.75 2.1 2.8 3.5
125 125 125 125 125 125 125 125 125 125 63 32
125 125 125 125 125 125 125 125 125 125 125 125
1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 2) 3)
0.0008 0.0009 0.0037 0.0042 0.01 0.035 0.064 0.089 0.15 0.18 0.23 0.45
400800101 400800102 400800103 400800104 400800105 400800106 400800107 400800108 400800109 400800110 400800111 400800112
3410.0310 3410.0311 3410.0312 3410.0313 3410.0314 3410.0315 3410.0316 3410.0317 3410.0318 3410.0319 3410.0320 3410.0321
1) 50 A @ 125 VAC / 300 A @ 125 VDC 2) 50 A @ 63 VAC / 50 A @ 125 VDC / 300 A @ 32 VDC 3) 50 A @ 32 VAC / 50 A @ 125 VDC / 300 A @ 32 VDC
Packaging Unit
Blister Tape on 18 cm Reel in ESD Plastic Bag
Time-Current-Curves
100000
10000
1000
100
10
Time in Seconds
1
0.1
0.01
0.001
0.0001 0.00001 1 10
Multiple of Rated Current In
2
Fuses
Non resettable fuses www.schurter.com/pg0_2
MGA-S
Order Entry
escc generic sPeciFication n˚ 4008
Production
Production with Product and Quality Tests
chart F2 - Production control
External Visiual Inspection according to Paragraph 5.2.1
Dimension Check according to Paragraph 5.2.2
Cold Resistance Initial Measurement according to Paragraph 5.2.1
Current Carrying Capacity and Overload Operation Test according to Paragraph 5.2.4/5.2.5
chart F3 - screening tests
Voltage drop Initial Measurement according to Paragraph 8.1.1.2
Burn-In (168h) according to Paragraph 8.3
Voltage drop Final Measurement according to Paragraph 8.1.1.2 Cold Resistance Final Measurement according to Paragraph 8.1.1.1
Test Equipment for Burn-In
External Visual Inspection according to Paragraph 8.2
Solderability according to Paragraph 8.4
Current Carrying Capacity and Overload Operation according to Paragraph 8.5/8.6
Check for Lot Failure according to Paragraph 6.4
Delivery with Test Report Summary Flight Model, see escc QPl Approved according to ESCC Generic Specification no. 4008 + ESCC Detail Specification no. 4008/001