Selector Chart For Power Entry Modules
For power entry
modules with line
filter, see page 49
Series / page number
AC inlet
NEW
Miniature
Module
NEW
Pcb
Mount
NEW
NEW
Pcb
Mount
CMF, page 31
KP, page 32
KP, page 32
KP, page 32
KEB, page 34
• low current
•
•
inlet / outlet
•
Fuseholder (5 x 20mm)
On/off line switch
Pcb
Mount
•
•
•
•
Voltage selector
NEW
Series / page number
Snap in
KEA, page 36
6200, page 35
GSF2, page 35
0040, page 37
KEC, page 38
AC inlet
•
•
•
•
•
Fuseholder (5 x 20mm)
•
•
• fuse clips
•
Fuseholder
•
(5 x 20mm or 1/4 x 11/4" )
On/off line switch
Voltage selector
•step
• step
8843
FELCOM
Series / page number
AC inlet
KD, page 39
KE, page 41
KG, page 42
8843, page 44
FELCOM, page 45
•
•
•
•
with or without outlet
•
•
•
•
•
with or without switch
• series/parallel
• series/parallel
Fuseholder (5 x 20mm)
Fuseholder
with / without fuseholder
(5 x 20mm or 1/4 x 11/4" )
On/off line switch
•
Voltage selector
• step
• series/parallel
with or without switch
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
29
About Power Entry Modules
Power entry modules integrate several component functions, thus reducing
panel space, parts count, and assembly time. For instance, the CG series
integrates a total of five components including RFI filter, IEC 320 inlet, 1- or
2-pole fuseholder for 1/ 4 x 11/ 4" or 5 x 20 mm fuses, series/parallel or DPDT
voltage selector, and a remote or integral on/off line switch. The remote switch
further reduces assembly time by eliminating the wiring between the front
panel, on/off switch, and the rear power entry module.Tool-only accessibility
requirements of medical standards IEC 601-1, BS 5724 part 1 and DIN/VDE
0750 part 1 can be satisfied by specifying medical fusedrawer ordering data.
Casing
Fuses
Fusedrawer
On / off
line switch
Voltage
selector
AC inlet
Options
Options for most power entry modules include: ac inlet without ground
terminal for protection class II equipment; various terminal types, including all
solder or quck-connect for Line and Neutral with solder for Ground; nonstandard internal connection wiring; red or green neon lighted switch;
Bowden units for customer supplied remote switch activation rods;
• Series KE, KG, CE and CG: ac inlet without ground terminal for protection
class II equipment available in 2-pole only.
• Voltage selector markings available other than those listed in the charts.
• Rivet mount modules available for series 6200, 6202, 6205 and 6220.
• Felcom series 64 and 54 modules available in custom configurations.
Accessories
For insulation cover and cord retaining clamp ordering data, see page 27.
For KE, KG, CE or CG voltage selector wiring cable, see page 43.
For cordsets, see pages xx-xx.
Materials
Casing and fusedrawer:
MultiFit modules KP, CMF
KEA, KEC/KFC,
KD/CD, KE/CE, KG/CG
KEB I & II, KFA,
6200-6220, 5200-5220, 0040
8843
Inlet prongs:
MultiFit KP, CMF
KEB/KFB I, 8843, 0040, KEA/KFA,
KEC/KFC, KD/CD, KE/CE, KG/CG
KEB/KFB I & II
thermoplastic PA 6.6 (UL 94V-O)
fiberglass reinforced thermoplastic
PETP (UL 94V-O)
thermoplastic PA 6.6 (UL 94V-O)
thermoplastic, polyester (UL 94V-O)
tin-plated brass
nickel-plated brass
nickel- and tin-plated brass
Power Dissipation
Max. power dissipation values are listed on the individual pages. See pages
3-5 for additional shock safety and power dissipation guidelines and data.
Voltage Selection Charts For Fusedrawers
Selection Chart for Series KEA, KFA
(KFA available with 3 positions max.)
Fusedrawer
Voltage markings /
Order Numbers
terminal markings
KEA, KFA
1
2
3
4301.XXXX.01 *
110
150
220
4301.XXXX.02
120
—
240
4301.XXXX.03
110
—
220
4301.XXXX.04
115
—
220
4301.XXXX.05
110
—
230
4301.XXXX.06
115
—
230
4301.XXXX.07
100
110
220
4301.XXXX.08
100
120
220
4301.XXXX.09
110
—
117
4301.XXXX.10
220
—
240
4301.XXXX.11
120
220
240
4301.XXXX.12
110
220
240
4301.XXXX.13
115
220
240
4301.XXXX.14
—
—
—
4301.XXXX.15
100
120
220
4301.XXXX.16
50Hz
—
60Hz
4301.XXXX.17
220
—
110
4301.XXXX.18
110
240
220
4301.XXXX.19
117
220
240
4301.XXXX.20
100
110
127
4301.XXXX.21
110
120
220
4301.XXXX.22
110
220
230
4301.XXXX.23
100
115
220
4301.XXXX.24
115
230
240
4
—
—
—
—
—
—
240
240
—
—
—
—
—
—
—
—
—
—
—
230
—
—
240
—
* Standard version
Selection Chart for Series KEC, KFC, KD, CD
(KFC available with 3 positions max.)
Fusedrawer
Voltage markings /
Order Numbers
terminal markings
KEC, KFC
1
2
3
KD, CD
3
4
5
4303.XXXX.00
—
—
—
4303.XXXX.01 *
100
120
220
4303.XXXX.02
110
150
220
4303.XXXX.03
110
—
220
4303.XXXX.04
110
220
240
4303.XXXX.05
115
—
230
4303.XXXX.06
117
220
240
4303.XXXX.07
100
117
220
4303.XXXX.08
110V
—
220V
4303.XXXX.09
220
—
240
4303.XXXX.10
115
220
240
4303.XXXX.11
110
120
220
4303.XXXX.12
115
230
240
4303.XXXX.13
100
110
220
4303.XXXX.14
100
117
220
4303.XXXX.15
100
115
230
4303.XXXX.16
100
120
230
4303.XXXX.17
115
120
230
4303.XXXX.18
115
—
240
4303.XXXX.19
220
120
240
4303.XXXX.20
100
120
230
4303.XXXX.21
100
—
220
4303.XXXX.22
100
120
220
4303.XXXX.23
100
110
120
4
6
—
240
—
—
—
—
—
—
—
—
—
240
—
240
240
—
240
240
—
230
—
—
230
—
* Standard version
Terminals:
MultiFit KP, CMF
KEC/KFC, KD/CD, KE/CE, KG/CG,
Felcom 54/64, 6200/6220, 5200/5220
KEB/KFB I & II, KFA
8843, 0040
30
tin-plated brass
For More Information
tin-plated brass
silver- and tin-plated brass
nickel-plated brass
Contact Schurter at the numbers listed below for non-standard part numbers
and order minimums, or for any other questions you may have regarding
options, accessories, materials or power dissipation.
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
CMF Low Current AC Inlet with On / Off Line Switch
NEW
Switch on left or right of AC inlet
Shown with rear insulation cover
• Miniature power entry module with integral 1-pole on/off line switch
• For cold connections 65˚C, Protection Class I or II
• Pcb mount with snap-in stabilizing feet; center screw mounts to
housing, or to pcb from above or below
• Body designed to protrude through panel opening
• SPST switch, 40A inrush maximum
• Electrical connections between mains inlet and switch done on the pcb
• Resistance to vibration according to IEC 68-2-6/Fc
• Rear insulation cover protects against inadvertent electrical contact
• For materials, options and accessories, see page 30
• For inlet/switch with 10A rating, see KEB on page 34
• For international cordsets, see page 26
UL
CSA
VDE
SEMKO
SEV
recognition
certification
approval
approval
approval
2.5A/250V
2.5A/250V
2.5A/250V
2.5A/250V
2.5A/250V
File #E96454
File #LR38456
File #93511
File
numbers
on request
7A, 250V UL/CSA version available; contact factory for pricing and order minimum
C8 inlet
C6 inlet
C8 inlet polarized
(acc. to IEC 320-1)
(acc. to Nema 1-115P)
Panel
Mounting from
above
Socket
Mounting from
below
4
with
insulation
cover
Housing
Pcb 1.6 mm
socket
cover
switch
with
insulation
cover
Panel
center screw
Pcb
Drilling diagram
Dimensions not tolerated ≤ 15 = ± 0.05
> 15 = ± 0.10
The size of the mounting cut-out can
be selected as required.
Mounting screw torque 0.5 Nm
Order Numbers
CMF
CMF1.1111.12
CMF1.1011.12
CMF1.1131.12
CMF1.1031.12
CMF2.1111.12
CMF2.1011.12
CMF2.1131.12
CMF2.1031.12
CMF3.1112.12
CMF3.1012.12
CMF3.1132.12
CMF3.1032.12
Appl. inlet
C8
Appl. inlet
polarized
Appl. inlet
C6
Cover mounted
•
•
•
•
•
•
Rocker switch
with inscript.0-I
•
•
•
•
•
•
•
•
•
•
•
•
Mounting
from above
•
•
Mounting
from below
•
•
•
•
•
•
•
•
•
•
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
31
KP
Pcb Mount, Snap-in or Screw-on • AC Inlet • AC Outlet • On / off Line Switch
Fuseholder for 5 x 20mm Fuses
NEW
AC inlet / switch
Medical
Fusedrawer
• Power entry module with line switch, fuseholder or inlet/outlet
• For “cold” connections 65° C, Protection Class I.
• Pcb mount with snap-in or screw-on feet (self-tapping M3 screws
provided, ø 3 x 8mm)
• Panel mount from rear or "sandwich" between top and bottom / side to
side panels
• Single or double pole shocksafe fuseholder according to IEC 65/VDE
0860 for 5 x 20mm fuses
• Integral 1-pole SPST on/off line switch or 2-pole DPST switch (70A/34ms in-rush max.; 10,000 cycles lifetime)
• Insulation cover in back protects against inadvertant electric contact
• Ground terminal solder/quick-connect .187 x .032" (4.8 x 0.8mm) or
.250 x .032" (6.3 x 0.8mm)
• 0.5 Nm screw torque required for screw-on type
• Max. power dissipation 3.2 watts (1-pole fusing) or 5 watts (2-pole fusing)
according to IEC 127-6. For additional values Pv in function of Tamb , see
page 5.
• For materials, options and accessories please see page 30
• For inlets with piggy-back fuse clips see GSF, page 13-14
AC inlet / fuseholder
UL
CSA
VDE
SEMKO
SEV
recognition
certification
approval
approval
approval
1)
2)
UL
CSA
VDE
SEMKO
SEV
AC inlet / outlet
Inlet / switch
10A/250V 1) File #E96454
10A/250V 1) File #LR38456
10A/250V 2) File #83482
10A/250V 2)
10A/250V 2)
Inlet / outlet
10A/250V File #E103791
10A/250V File #LR38456
10A/250V File #83482
File
10A/250V
numbers
10A/250V
on request
10A/250V approval with 1/2 HP; 10A/125V approval with 1/3 HP
4A inductive load
recognitation
certification
approval
approval
approval
Inlet / fuseholder
10A/250V File #E93617
10A/250V File #LR38456
10A/250V File #83482
File numbers
10A/250V
on request
10A/250V
Optional “back-pack” filter
(see KPF, pg. 55)
Optional “back-pack” surge
protector (see KPS, pg. 55)
Standards: IEC 320/C14/F; IEC 127-6; EN 60320; EN 60127-6. Fusedrawer meets toolonly accessibility requirements of medical standards IEC 601-1, BS5724 part 1, DIN/VDE
0750 part 1.
Snap-in pcb mounting
see next page for drilling diagram and panel cut-out
32
Cascading multi-function design
streamlines packaging
Screw-on pcb mounting
see next page for drilling diagram and panel cut-out
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
KP continued
Printed circuit board mounting
Order Numbers (to order fuses, see page 102)
KP01. 1 X X X . X X 9 0 (add 90 when used in conjunction with
snap-on filter or surge protector)
Stable snap feet requires
minimal insertion force
Module must lay flat on the
pcb when soldering (see
diagram below)
Ground Terminal
1* = protection class I, solder/quick-connect
4.8 x 0.8mm, in connector axis
2 = protection class I, solder/quick-connect
6.3 x 0.8mm, in connector axis
6 = protection class I, solder/quick-connect
4.8 x 0.8mm, 90˚ to connector axis
7 = protection class I, solder/quick-connect
6.3 x 0.8mm, 90˚ to connector axis
Line switch
0 = without switch
non-illuminated
1* = black
2 = white
3 = red
4 = green
5 = orange
Screw-on mount uses selftapping screws
0.5 Nm torque required for
screws
For 2-pole inlet/switch,2-pole
inlet/fuseholder and inlet/outlet
For 1-pole inlet/switch and
1-pole inlet/fuseholder
Other dimensions for
2-pole modules:
d1 = 6 ± 0.05 (snap-in)
d1 = 3.6 (screw-on)
d2 = 2 ± 0.1 (screw-on)
Tolerances not marked:
≤ 15 = ± 0.05
≥ 15 = ± 0.1
Panel mounting
Insertion
from behind
illuminated 100- 250V~
7* = red
8* = green
9 = orange
Mounting
For snap-in Pcb mount (thickness 1.6 mm):
11 = slot for panel, thickness S = 1.0mm
12* = slot for panel, thickness S = 1.5 – 2.0mm
13* = slot for panel, thickness S = 2.5 – 3.0mm
14 = slot for panel, thickness S = 3.5 – 4.0mm
15 = without slot for panel fixation
For screw-on Pcb mount (thickness 1.2-2.5mm):
With or without self-tapping screws, ø3 x 8mm
With
Without
51
61
panel thickness S = 1.0mm
52*
62
panel thickness S = 1.5 – 2.0mm
53*
63
panel thickness S = 2.5 – 3.0mm
54
64
panel thickness S = 3.5 – 4.0mm
55
65
panel thickness S = 0
Standard combinations
0 = AC inlet with ac outlet
1 = AC inlet with on/off line switch, 2-pole
2 = AC inlet with on/off line switch, 1-pole
3 = AC inlet with fuseholder, 2-pole
4 = AC inlet with fuseholder, 1-pole
Color of Housing
1* = black
Basic Specification
KP01 = Power entry module for Pcb mounting,
SNAPFIT or SCREWFIT
* standard configuration. Contact Schurter for non-standard order minimums.
Ordering example:
KP01.1112.11
“Sandwich”
mounting with
split enclosure panels
Solder/quick-connect ground terminal 4.8 x 0.8mm
in connector axis
Black unlighted rocker switch
Snap-in pcb mounting (1.6mm pcb), with bezel for
1.5-2.0mm panel
Combination ac inlet with on/off line switch (2-pole)
Black housing
Power entry module for pcb mounting
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
33
KEB AC Inlet with On / Off Line Switch
CS
(VDE)
•
•
•
•
•
•
•
•
•
Power entry module with integral 1-pole or 2-pole on/off line switch
For “cold” connections 65° C, Protection Class I.
Screw mount from front or rear, or snap-in mount from front
SPST switch 60A in-rush max., unlighted(black) or lighted(red)
DPST switch 35A in-rush max., unlighted(black) or lighted(red or green)
Quick-connect terminals .187 x .032" (4.8 x 0.8mm)
0.5 Nm torque required for M3 screws for screw-on type
For materials, options and accessories please see page 30
For KEB with line filter, please see KFB on page 56
UL
CSA
VDE
SEMKO
SEV
CS
KEB 1-pole
10A/250V 1
10A/250V 1
10A/250V 2
10A/250V 2
10A/250V 2
10A/250V
recognition
certification
approval
approval
approval
certification
File #E96454
File #LR38456
File #3461, expert report
File
numbers
on request
1)
6A/250V with lighted DPST switch
2)
3A inductive load SPST; 4A inductive load DPST
KEB 2-pole
1-pole
unlighted
1-pole
lighted
2-pole
unlighted
2-pole
lighted
Standards:UL498;CSAC22.2182.3;DIN/VDE 0625;
SEMKO 9320; IEC 320/C14; EN 60320
KEB 1-pole
KEB 2-pole
lighted
unlighted
± 0.1 mm panel thickness tolerance required with snap-in modules
Order Numbers
KEB
1-pole switch
2-pole switch
4302.0001
4302.0002
4302.2001
4302.2002
4302.0003
4302.0004
4302.0101
4302.0102
4302.0103
4302.2003
4302.2004
4302.2101
4302.2102
4302.2103
4302.0104
4302.0121
4302.0122
4302.0123
4302.0124
4302.2104
4302.2141
4302.2142
4302.2143
4302.2144
34
Switch color / rating
unlighted / 250V
red lighted/ 250V
red lighted/ 125V (1-pole)
green lighted/ 250V (2-pole)
Mounting
Screw-on
Snap-in, 1.5mm panel thickness
Snap-in, 2.0mm panel thickness
Snap-in, 2.5mm panel thickness
Screw-on
Snap-in, 1.5mm panel thickness
Snap-in, 2.0mm panel thickness
Snap-in, 2.5mm panel thickness
Screw-on
Snap-in, 1.5mm panel thickness
Snap-in, 2.0mm panel thickness
Snap-in, 2.5mm panel thickness
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
6200 / 6220 AC Inlet with 5 x 20mm Fuseholder
• Power entry module with 1-pole (6200) or 2-pole (6220) fuseholder.
1-pole fuseholder has spare fuse compartment (Class I only).
• For “cold” connections 65° C, Protection Class I or Class II (6202)
• Screw mount from front or rear, or snap-in mount from front
• Single or double pole shocksafe fuseholder according to
IEC 65/VDE 0860 for 5 x 20mm fuses
• Quick-connect terminals .187 x .032" (4.8 x 0.8mm) or .250 x .032"
(6.3 x 0.8mm); or solder terminals .138 x .032" (3.5 x 0.8mm)
• 0.5 Nm torque required for M3 screws for screw-on type
• Max. power dissipation 1.7 watts(6200) and 3.1 watts(6220) according
to IEC 127-6. For additional values Pv in function of Tamb , see page 5
• For materials, options and accessories please see page 30
• For 6200/6220 with line filter, please see 5200/5220 on page 57
• For inlets with piggy-back fuse clips see GSF, pg. 13-14
With Captive
Fusedrawer
6200
1-pole
6220
2-pole
UL
CSA
VDE
SEMKO
SEV
Plug Removal
Necessary for
Fuse Replacement
recognition
certification
approval
aooroval
approval
Standards: UL 498; CSA C22.2/182.3; DIN/VDE 0625; SEMKO 9320; IEC 320/
C14/C18; EN 60320. 6200 fusedrawer meets requirements of medical standards
IEC 601-1, BS5724 part 1, DIN/VDE 0750 part 1.
10A/250V
10A/250V
10A/250V
10A/250V
10A/250V
File #E96317
File #LR38456
File #2324, expert report
File
numbers
on request
6200
6200
6220
6220
S = panel thickness 1.0, 1.5, 2.0, 2.5, 3.0mm
E = solder terminals 20.5mm; quick-connect terminals 23.5mm
Order Numbers (type)
Note: Casing and fusedrawer combined. To order fuses, please see page
pages102
99-130.
6200, 1-pole fusing
Screw-on
Class I
Class II
Class I
Snap-in
Class I
(w/o internal connections)
Class I
6220, 2-pole fusing
Screw-on
Class I
Snap-in
Class I
Terminal Type
(w/o internal connections)
6200.2100
6200-21
6202.2100*
6202-21
6205.2100*
6205-21
6200.41XX
6200-41/...
6205.41XX*
6205-41/...
6220.2100
6220-21
6220.51XX
6220-51/...
solder
.138" x .032" (3.5 x 0.8mm)
6200.2200
6200-22
6202.2200*
6202-22
6205.2200*
6205-22
6200.42XX
6200-42/...
6205.42XX*
6205-42/...
6220.2200
6220-22
6220.52XX
6220-52/...
quick-connect
.187" x .032" (4.8 x 0.8mm)
6200-2300
6202.2300*
6205.2300*
6200.43XX
6205.43XX*
6220.2300
6220.53XX
quick-connect
6205-43/...
6220-23
6220-53/...
.250" x .032" (6.3 x 0.8mm)
6200-23
6202-23
6205-23
6200-43/...
XX = panel thickness 1.0, 1.5, 2.0, 2.5, 3.0mm (e.g. 6200.4110 = 1.0mm)
To order rivet mount type, change the fifth digit in the part number from a "2" to a "9" (e.g. 6200.9100, 6202.9100). Contact Schurter for order minimum.
* Contact Schurter for order minimum
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
35
KEA AC Inlet with 5 x 20mm Fuseholder
(VDE)
•
•
•
•
Plug Removal
Necessary for
Fuse Replacement
•
•
•
•
•
•
•
Power entry module with 1-pole or 2-pole fuseholder
For “cold” connections 65° C, Protection Class I.
Screw mount from front or rear, or snap-in mount from front
Single or double pole shocksafe fuseholder according to
IEC 65/VDE 0860 for 5 x 20mm fuses (plug removal necessary for fuse
replacement)
Optional voltage selector with 2-4 step switch positions
Quick-connect terminals .187 x .032" (4.8 x 0.8mm) or pcb terminals
0.5 Nm torque required for M3 screws for screw-on type
Max. power dissipation 3.5 watts (2 pole fusing) according to IEC 127-6.
For additional values Pv in function of Tamb , see page 5.
For materials, options and accessories please see page 30
For KEA with line filter, please see KFA on page 58
For inlet with piggy-back fuse clips see GSF, pg. 13-14
UL
CSA
VDE
SEMKO
SEV
recognition
certification
approval
approval
approval
10A/250V
10A/250V
10A/250V
10A/250V
10A/250V
File #E93617
File #LR38456
File #1996, expert report
File
numbers
on request
Standards: UL 498; CSA C22.2/182.3; DIN/VDE 0625; SEMKO 9320; IEC 320/C14; EN
60320. Medical fusedrawers meet tool-only accessibility requirements of medical
standards IEC 601-1, BS5724 part 1, DIN/VDE 0750 part 1. U.S. Patented.
without
voltage
selector
with
voltage
selector,
2-step
with int.
connections;
3-step
voltage
selector
without int.
connections;
4-step
voltage
selector
Pcb mount
(with
internal
connections)
1-pole
schematics
without
voltage
selector
with int..
connections;
3-step
voltage
selector
with
voltage
selector,
2-step
without int.
connections;
4-step
voltage
selector
Pcb mount
(with
internal
connections)
2-pole
schematics
Screw-on
Snap-in
Pcb mount
1-pole
2-pole
Raster: 1/10" = 2.54mm
Drillings: 3/5/N = ø1.3 +0.1
= ø1.6 +0.1
± 0.1 mm panel thickness tolerance required with snap-in modules
Order Numbers
Note: Casing and fusedrawer must be ordered separately. To order fuses, please see pgs
page97-128.
102
Casing
KEA w/o voltage selector
2-pole fusing
1-pole fusing
KEA with voltage selector
1-pole fusing
2-pole fusing
KEA pcb mnt., w/o volt. selector
1-pole fusing
2-pole fusing
4301.0521
4301.0522
4301.0523
4301.0524
4301.0021
4301.0022
4301.0023
4301.0024
4301.2061
4301.0001
4301.0002
4301.0003
4301.0004
4301.2041
4301.3211
4301.3212
4301.3213
4301.3214
4301.2062
4301.2063
4301.2064
4301.2042
4301.2043
4301.2044
4301.0501
4301.0502
4301.0503
4301.0504
Part numbers without internal
connections on request
4301.3201
4301.3202
4301.3203
4301.3204
Part numbers without internal
connections on request
Voltage Internal
Selector Connections
2-3 pos.,
(n/a pcb
type)
with
3-4 pos.,
(n/a pcb
type)
without
Mounting
Screw-on
Snap-in, 1.5mm panel thickness
Snap-in, 2.0mm panel thickness
Snap-in, 2.5mm panel thickness
Screw-on
Snap-in, 1.5mm panel thickness
Snap-in, 2.0mm panel thickness
Snap-in, 2.5mm panel thickness
Fusedrawer
Voltage markings / terminal
markings: 1 2 3 4
With voltage selector: see
30 for .XX
selector chart on page 23
Without voltage selector
36
5 x 20mm
1-pole + spare
2-pole black, with shorting bar
1-pole black
2-pole black
fuse-case
in the neutral side
Standard
4301.1214.XX
4301.1014.XX
4301.2814.XX
4301.3536.XX
Medical *
4301.1224.XX
4301.1024.XX
4301.2824.XX
4301.3537.XX
Standard
4301.1405
4301.1401
4301.1409
4301.1413
Medical *
4301.1407
4301.1403
4301.1411
4301.1415
* Meets tool-only accessibility requirements of medical standards IEC 601-1, BS 5724 part 1, DIN/VDE 0750 part 1
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
0040 AC Inlet with 5 x 20mm Fuseholder
•
•
•
•
Note: Not recommended for
new designs. Refer to KEA
(pg. 36), GSF (pg. 13/14) or
6220 (pg. 35)
Standards: UL 498; CSA
C22.2/182.3; DIN/VDE
0625; SEMKO 9320; IEC
320/C14/C18; EN 60320
•
•
•
•
•
Power entry module with 1-pole or 2-pole fuseholder
For “cold” connections 65° C, Protection Class I or II
Screw mount from front
Single or double pole shocksafe fuseholder according to IEC 65/VDE
0860 for 5 x 20mm fuses
Quick-connect terminals .187 x .032" (4.8 x 0.8mm)
0.5 Nm torque required for M3 screws
Max. power dissipation 2.4 watts (2-pole fusing) according to IEC 127-6.
For additional values Pv in function of Tamb , see page 5
For materials, options and accessories please see page 30
For inlet with piggy-back fuse clips see GSF, page 13-14
UL
CSA
VDE
SEMKO
SEV
recognition
certification
approval
approval
approval
10A/250V
10A/250V
6A/250V
10A/250V
10A/250V
File #E93617
File #LR38456
File #19397
File
numbers
on request
Order Numbers (type)
Note: Casing and fusedrawer combined. To order fuses, please see pgs
page99-130.
102.
Series 0040
Class I
0040.5000.2
8843-2.SP.FL.4/3.60
0040.5001.2
8843-2.SP.FL.4/3.64
0040.5012
8843-2.SP.U.FL.4/3.60
8843
Class II
0040.5015
8842-2.SP.FL.4/3.60
Color/Fusing
black/2-pole
grey/2-pole
black/1-pole
Terminal Type
solder
.138" x .032" (3.5 x 0.8mm)
quick-connect
.187" x .032" (4.8 x 0.8mm)
quick-connect
.250" x .032" (6.3 x 0.8mm)
AC Inlet • Interchangeable Fuseholders for 1/4 x 11/4" or 5 x 20mm Fuses
Standards: UL 498; CSA C22.2/
182.3; DIN/VDE 0625; SEMKO
9320; IEC 320/C14; EN 60320.
U.S. Patented.
• Power entry module with 1-pole or 2-pole fuseholder
• For “cold” connections 65° C, Protection Class I.
• Screw mount from front or rear, or snap-in mount from front (0.8-3.0mm
panel thickness)
• Single or double pole shocksafe fuseholder according to IEC 65/VDE
0860 for 1/4 x 11/4" or 5 x 20mm fuses
• Quick-connect terminals .187 x .032" (4.8 x 0.8mm) or solder .138 x
.032" (3.0 x 0.8mm).
• 0.5 Nm torque required for M3 screws for screw-on type
• Max. power dissipation 5.5 watts (2 pole fusing, unfiltered) according to
IEC 127-6. For additional values Pv in function of Tamb , see page 6
• For materials, options and accessories please see page 30
• For 8843 with line filter, please see 8843 on page 59
• For inlet with piggy-back fuse clips see GSF, page 13-14
UL
CSA
VDE
SEMKO
SEV
recognition
certification
approval
approval
approval
10A/250V
10A/250V
10A/250V
10A/250V
10A/250V
File #E96317
File #LR38456
File #3157, expert report
File
numbers
on request
Order Numbers (type) Note: Casing and fuseholders must be ordered separately. To order fuses, please see page
pgs 99-130.
102.
Casing
8843
1-pole fusing
8843.0351
8843.0353
8843.0451
8843.0453
2-pole fusing
(8843-351.60)
(8843-353.60)
(8843-451.60)
(8843-453.60)
8843.0361
8843.0363
8843.0461
8843.0463
(8843-361.60)
(8843-363.60)
(8843-461.60)
(8843-463.60)
Terminals
Solder .138" X .032" (3.0 x 0.8mm)
Quick-connect .187" x .032" (4.8 x 0.8mm)
Solder .138" X .032" (3.0 x 0.8mm)
Quick-connect .187" x .032" (4.8 x 0.8mm)
Mounting
Screw-on
Screw-on
Snap-in,0.8-3.0mm panel thickness
Snap-in,0.8-3.0mm panel thickness
Fuseholder inserts* (2 inserts
must be ordered for 2-pole fusing)
8843.0901
1/4 x 1 1/4"
8843-901.60
(6.3x32mm)
8843.0902
for 5 x 20mm
8843-902.60
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
37
KEC AC Inlet • Interchangeable Fuseholders for / x 1 / " or 5 x 20mm Fuses
1
1
4
•
•
•
•
•
•
•
•
•
•
•
recognition
certification
certification
VDE
approval
SEMKO approval
SEV
approval
Standards: UL 498; CSA C22.2/182.3; DIN/VDE 0625; SEMKO 9320; IEC 320/C14; EN
60320. Medical fusedrawers meet tool-only accessibility requirements of medical
standards IEC 601-1; BS5724 part 1, DIN/VDE 0750 part 1. U.S. Patented.
with
voltage
selector,
2-step
Power entry module with 1-pole or 2-pole fuseholder
For “cold” connections 65° C, Protection Class I.
Screw mount from front or rear, or snap-in mount from front
Single or double pole shocksafe fuseholder according to
IEC 65/VDE 0860 for 1/ 4 x 11/ 4" or 5 x 20mm fuses
Optional voltage selector with 2-4 step switch positions
Quick-connect terminals .187 x .032" (4.8 x 0.8mm)
0.5 Nm torque required for M3 screws for screw-on type
Max. power dissipation 5.5 watts (2 pole fusing) according to IEC 127-6.
For additional values Pv in function of Tamb , see page 5
For materials, options and accessories please see page 30
For KEC with line filter, please see KFC on page 60
For inlet with piggy-back fuse clips see GSF, pg. 13-14
UL
CSA
Standard or
Medical
Fusedrawer
without
voltage
selector
4
with int.
connections;
3-step volt.
selector
with int.
connections;
4-step volt.
selector
without int.
connections;
4-step volt.
selector
without
voltage
selector
1-pole
schematics
15A/250V
16A/250V
10A/250V
10A/250V
10A/250V
10A/250V
with
voltage
selector,
2-step
File #E93617
Single pole File #LR38456
Double pole File #LR38456
File #1996, expert report
File
numbers
on request
with int.
connections;
3-step
voltage
selector
with int.
connections;
4-step volt.
selector
without int.
connections;
4-step volt.
selector
2-pole
schematics
± 0.1 mm panel thickness tolerance required with snap-in modules
Order Numbers
Note: Casing and fusedrawer must be ordered separately. To order fuses, please see page
pgs 99-130.
102.
Casing
KEC w/o voltage selector,
with internal connections
2-pole fusing
1-pole fusing
KEC with voltage selector,
with internal connections
1-pole fusing
2-pole fusing
KEC with voltage selector,
without internal connections
1-pole fusing
2-pole fusing
4303.0031
4303.0001
4303.0091
4303.0061
4303.1091
4303.1061
4303.0032
4303.0033
4303.0034
4303.0002
4303.0003
4303.0004
4303.0092
4303.0093
4303.0094
4303.0211
4303.0212
4303.0062
4303.0063
4303.0064
4303.0181
4303.0182
4303.1092
4303.1093
4303.1094
4303.1211
4303.1212
4303.1062
4303.1063
4303.1064
4303.1181
4303.1182
4303.0213
4303.0214
4303.0183
4303.0184
4303.1213
4303.1214
4303.1183
4303.1184
Voltage Selector Mounting
Screw-on
3-4 pos.
2 pos.
Snap-in, 1.5mm panel thickness
Snap-in, 2.0mm panel thickness
Snap-in, 2.5mm panel thickness
Screw-on
Snap-in, 1.5mm panel thickness
Snap-in, 2.0mm panel thickness
Snap-in, 2.5mm panel thickness
Fusedrawer
Voltage markings / terminal
markings: 1 2 3 4
With voltage selector: see
selector chart on page 30 for .XX
Standard
Medical *
Standard
5 x 20mm
1-pole black
4303.2114.XX
4303.2124.XX
4303.2406
2-pole black
4303.2014.XX
4303.2024.XX
4303.2401
2-pole black,
with shorting bar
in the neutral side
4303.2036.XX
4303.2037.XX
4303.2411
1/4" x 1-1/4"
(6.3 x 32mm)
1-pole grey
4303.2814.XX
4303.2824.XX
4303.2907
2-pole grey
4303.2714.XX
4303.2724.XX
4303.2902
2-pole grey,
with shorting bar
in the neutral side
4303.2736.XX
4303.2737.XX
4303.2912
Without voltage selector
Medical *
4303.2408
4303.2403
4303.2413
4303.2909
4303.2904
4303.2914
* Meets tool-only accessibility requirements of medical standards IEC 601-1, BS 5724 part 1, DIN/VDE 0750 part 1
38
Black
on
request
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
KD
AC Inlet • On/off Line Switch – Integral or Remote • Voltage Selector •
Interchangeable Fusedrawers for 1/4 x 11/4" or 5 x 20mm Fuses
Mechanical pushbutton
for front or side panel
actuation
•
•
•
•
Power entry module with 1-pole or 2-pole fuseholder
For “cold” connections 65° C, Protection Class I.
Screw mount from front or rear, or snap-in mount from front
Single or double pole shocksafe fuseholder according to
IEC 65/VDE 0860 for 1 /4 x 11 /4" or 5 x 20mm fuses
Integral DPST on/off line switch (35A in-rush max.) or DPST switch with
remote mechanical pushbutton (64A in-rush max.;10,000 cycles lifetime)
Optional voltage selector with 2-4 step switch positions
Quick-connect terminals .187 x .032" (4.8 x 0.8mm)
0.5 Nm torque required for M3 screws for screw-on type
Max. power dissipation 5.5 watts (2 pole fusing) according to IEC 127-6.
For additional values Pv in function of Tamb , see page 5
For materials, options and accessories please see page 30
For KD with line filter, please see CD on page 61
B1
•
•
•
•
•
Fusedrawer
RFI shielded
Bowden cable
eliminates wiring
between switch and
power entry module
•
•
Mechanical switching
mechanism
UL
CSA
VDE
SEMKO
SEV
recognition
certification
approval
approval
approval
1)
2)
8A/125V
without
Bowden cable
10A/250V
10A/250V 2)
10A/250V 3)
10A/250V 3)
10A/250V 3)
6A/250V with lighted switch
with
Bowden cable
6A/250V 1)
6A/250V 1)
10A/250V 3,4)
6A/250V 3)
6A/250V 3)
File #E93617
File #LR38456
File #1996, expert report
3)
4)
4A inductive load
File
numbers
on request
6A max. switch rating
Standard or
Medical
Fusedrawer
1 Pole
Casing (internally wired)
2 Poles
Standards: UL 498; CSA C22.2/182.3; DIN/VDE 0625; SEMKO 9320; IEC 320/C14; EN
60320. Medical fusedrawers meet tool-only accessibility requirements of medical
standards IEC 601-1, BS5724 part 1, DIN/VDE 0750 part 1. U.S. Patented.
2 Poles
1 Pole
Without Voltage Selector
Voltage
Selector
2 step
2 Poles
1 Pole
Voltage Selector; 4 step
Voltage Selector; 4
step; Bowdenzug
Mounting
hole B1
± 0.1 mm panel thickness tolerance required with snap-in modules
Order Numbers
page 102.
Important Note: Casing, fusedrawer and Bowden cable must be ordered separately. To
Seeorder
pages
97-128
for fuses.
fuses,
please
see pages
99-130.
Casing
KD without Bowden cable
1-Pole fusing
2-Pole fusing
KD13.1101.151
KD14.1101.151
KD13.1101.105
KD14.1101.105
KD13.1101.107
KD14.1101.107
KD13.1101.109
KD14.1101.109
KD13.4101.151
KD14.4101.151
KD13.4101.105
KD14.4101.105
KD13.4101.107
KD14.4101.107
KD13.4101.109
KD14.4101.109
KD with Bowden cable
1-Pole fusing
2-Pole fusing
KD11.4199.151
KD14.4199.151
KD11.4199.105
KD14.4199.105
KD11.4199.107
KD14.4199.107
KD11.4199.109
KD14.4199.109
KD11.4199.151
KD14.4199.151
KD11.4199.105
KD14.4199.105
KD11.4199.107
KD14.4199.107
KD11.4199.109
KD14.4199.109
Voltage Selector
without
without
without
without
2-4 positions
2-4 positions
2-4 positions
2-4 positions
Mounting
screw-in
snap-in, for 1.5mm panel
snap-in, for 2.0mm panel
snap-in, for 2.5mm panel
screw-in
snap-in, for 1.5mm panel
snap-in, for 2.0mm panel
snap-in, for 2.5mm panel
Bowden Cable
Bowden cables are
supplied in standard
or custom lengths
Please see page
40 for ordering instructions
Fusedrawer
Voltage markings / terminal
markings: 3 4 5 6
With voltage selector: see
selector chart on page 30
23 for .XX
Without voltage selector
2-pole black,
1/4" x 1-1/4"
2-pole grey,
5 x 20mm
with shorting bar
(6.3 x 32mm)
with shorting bar
1-pole black
2-pole black
in the neutral side
1-pole grey
2-pole grey
in the neutral side
Standard
4303.2114.XX
4303.2014.XX
4303.2036.XX
4303.2814.XX
4303.2714.XX
4303.2736.XX
Medical * 4303.2124.XX
4303.2024.XX
4303.2037.XX
4303.2824.XX
4303.2724.XX
4303.2737.XX
Standard
4303.2406
4303.2401
4303.2411
4303.2907
4303.2902
4303.2912
Medical * 4303.2408
4303.2403
4303.2413
4303.2909
4303.2904
4303.2914
* Meets tool-only accessibility requirements of medical standards IEC 601-1, BS 5724 part 1, DIN/VDE 0750 part 1
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
Black
on
request
39
Bowden Cable
(VDE)
Ordering Data
Custom Cable Lengths (please specify dimensions according to mounting illustrations)
Type R
Mounting
Type S
Mounting
Power entry module mounted parallel to switch
Power entry module mounted 90˚ to switch
Specify dimensions a, b & c in mm (center of mounting hole B1, outer
surface to center of mounting hole B2, outer surface).
Specify dimensions a, b & c in mm (center of mounting hole B1, outer
surface to center of mounting hole B2, outer surface).
R
a/
b/
S
c/
a/
b/
c/
Please allow 4-6 weeks delivery for custom cable sample. For a standard cable sample, use order number 886.0101. Note: carefully observe Bowden cable limitations as described in the Technical Data
section below. For optimum switch actuation, the length of the traction cable must be specified according to Schurter's catalog specifications.
Assembly Instructions
1. Drop Bowden barrel into
seat of switch
2. Slide clamp around cable
3. Bowden cable locked into
assembly
Technical Data
The remote actuator cable assembly
consists of a wire cable inside of a plastic
insulated spiral wire casing.
The principal element of lost motion is
backlash and deflection.
Identifying a proper routing of the cable
assembly is important. Deviations from line
to line placement will require bends in the
cable with resulting losses in the overall
assembly. These inefficiencies show up as
friction losses and lost motion.
Backlash is caused by the wire cable
moving inside the casing with the change in
direction of motion. It is the function of
clearance between the wire cable and
casing, plus the number of degrees of bend
in the cable assembly. Deflection of the
cable assembly, while usually low, can be
minimized by anchoring the casing.
Frictional losses are increases in actuation
force due to losses in the assembly. Lost
motion is an undesirable difference
between the input end of the assembly and
the output end.
This is especially true in those applications
of cable assemblies with long lengths and/
or large degrees of bend in the system.
40
All of these losses and resulting
inefficiencies can be reduced by the
equipment designer through minimizing the
total degrees of bend in the assembly.
Because of the number of variables
effecting proper operation of any remotely
actuated switch assembly, it is important
that the ordering instructions shown above
be used to determine proper cable length
and to provide samples for customer
approval. Consult figure for minimum
information required to describe cable
assembly application.
Percent Increase in Actuation Force
Remote Actuator Technology
180˚
“Courtesy of ITT Schadow”
Degrees of bend in assembly
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
KE
AC Inlet • Series Parallel Voltage Selector •
Interchangeable Fusedrawer for 1/4 x 11/4" or 5 x 20mm Fuses
•
•
•
•
•
•
•
•
•
•
(VDE)
Power entry module with 1-pole or 2-pole fuseholder
For “cold” connections 65° C, Protection Class I.
Screw mount from front or rear, or snap-in mount from front
Single or double pole shocksafe fuseholder according to
IEC 65/VDE 0860 for 1 /4 x 11 /4" or 5 x 20mm fuses
Voltage selector with series parallel connections; with 4, 3, or 2 switch
positions or usable as a 2-pole changeover switch
Quick-connect terminals .187 x .032" (4.8 x 0.8mm)
0.5 Nm torque required for M3 screws for screw-on type
Max. power dissipation 5.5 watts (2 pole fusing) according to IEC 127-6.
For additional values Pv in function of Tamb , see page 5
For materials, options and accessories please see page 30
For KE with line filter, please see CE on page 62
UL
CSA
recognition 15A/250V
certification 12A/250V
10A/250V
VDE
approval
10A/250V
SEMKO approval
10A/250V
SEV
approval
10A/250V
Medical
Fusedrawer
with internal connections
File #E93617
1-Pole fusing, file #LR38456
2-Pole fusing, file #LR38456
File #3189, expert report
File
numbers
on request
without internal connections
Optional accessory
cable for voltage
selector wiring shown
on page 43
Standards: UL 498; CSA C22.2/182.3; DIN/VDE 0625; SEMKO 9320; IEC 320/C14; EN
60320. Fusedrawers meet tool-only accessibility requirements of medical standards IEC
601-1, BS5724 part 1, DIN/VDE 0750 part 1.
1-pole
2-pole
1-pole
2-pole
± 0.1 mm panel thickness tolerance required with snap-in modules
Order Numbers
Three order numbers are needed to specify the KE, complete with casing, voltage selector insert and fusedrawer. For example:
1. KE10.6100.151 = Casing for screw mounting with internal connections and 2-pole protection
2. 4305.0048.01 = Voltage Selector Insert with markings 100, 120, 220, 240
3. 4305.0001
= Fusedrawer with 2-pole protection for 5 x 20mm fuses
Casing
KE with internal connections
2-pole fusing
1-pole fusing
KE without internal connections
1-pole fusing
2-pole fusing
Mounting
KE16.5100.151
KE16.5100.105
KE16.5100.107
KE16.5100.109
KE15.1100.151
KE15.1100.105
KE15.1100.107
KE15.1100.109
Screw on
Snap-in, 1.5mm panel thickness
Snap-in, 2.0mm panel thickness
Snap-in, 2.5mm panel thickness
KE10.6100.151
KE10.6100.105
KE10.6100.107
KE10.6100.109
KE10.2100.151
KE10.2100.105
KE10.2100.107
KE10.2100.109
102.
Order numbers for voltage selector insert and fusedrawer shown on pg 43.
35. To
Toorder
orderfuses,
fuses,please
pleasesee
seepage
pgs 97-128.
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
41
Inlet • On/off Line Switch – Integral or Remote • Series Parallel Voltage
KG AC
Selector • Interchangeable Fusedrawer for / x 1 / " or 5 x 20mm Fuses
1
4
1
•
•
•
•
B1
(VDE)
4
•
•
•
•
•
•
•
Power entry module with 1-pole or 2-pole fuseholder
For “cold” connections 65° C, Protection Class I.
Screw mount from front or rear, or snap-in mount from front
Single or double pole shocksafe fuseholder according to
IEC 65/VDE 0860 for 1 /4 x 11 /4" or 5 x 20mm fuses
Integral DPST on/off line switch (35A in-rush max.) or DPST switch with
remote mechanical pushbutton (64A in-rush max.;10,000 cycles lifetime)
Voltage selector with series parallel connections, with 4, 3, or 2 switch
positions or usable as a 2-pole changeover switch
Quick-connect terminals .187 x .032" (4.8 x 0.8mm)
0.5 Nm torque required for M3 screws for screw-on type
Max. power dissipation 5.5 watts (2 pole fusing) according to IEC 127-6.
For additional values Pv in function of Tamb , see page 5
For materials, options and accessories please see page 30
For KG with line filter, please see CG on page 63
UL
CSA
VDE
SEMKO
SEV
recognition
certification
approval
approval
approval
without
Bowden cable
10A/250V
10A/250V
10A/250V 2)
10A/250V 2)
10A/250V 2)
with
Bowden cable
6A/250V 1)
6A/250V 1)
6A/250V
6A/250V
6A/250V
1)
2)
8A/125V
4A inductive load
1-pole
Medical
Fusedrawer
File #E93617
File #LR38456
File #3772, expert report
File
numbers
on request
2-pole
with internal
connections
Optional accessory
cable for voltage
selector wiring shown
on page 43
Standards: UL 498; CSA C22.2/182.3; DIN/VDE 0625; SEMKO 9320; IEC 320/C14; EN
60320. Fusedrawers meet tool-only accessibility requirements of medical standards IEC
601-1, BS5724 part 1, DIN/VDE 0750 part 1.
Mounting
hole B1
± 0.1 mm panel thickness tolerance required with snap-in modules
Order Numbers
Three order numbers are needed to specify the KG, complete with casing, voltage selector insert and fusedrawer. For example:
1. KG10.6101.151 = KG for screw mounting with 2-pole protection
2. 4305.0048.01 = Voltage Selector Insert with markings 100, 120, 220, 240
3. 4305.0001
= Fusedrawer with 2-pole protection for 5 x 20mm fuses
Casing
KG without Bowden cable
2-pole fusing
1-pole fusing
KG with Bowden cable
1-pole fusing
2-pole fusing
Mounting
Bowden Cable
KG16.5101.151
KG16.5101.105
KG16.5101.107
KG16.5101.109
KG15.6199.151
KG15.6199.105
KG15.6199.107
KG15.6199.109
Screw on
Snap-in, 1.5mm panel thickness
Snap-in, 2.0mm panel thickness
Snap-in, 2.5mm panel thickness
Bowden Cables are supplied
in standard or custom
lengths. Please see page 32
33
for ordering instructions.
KG10.6101.151
KG10.6101.105
KG10.6101.107
KG10.6101.109
KG10.6199.151
KG10.6199.105
KG10.6199.107
KG10.6199.109
Order numbers for voltage selector insert and fusedrawer shown on pg 43.
35. To
Toorder
orderfuses,
fuses,please
pleasesee
seepage
pgs 97-128.
102.
42
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
KE, KG, CE, CG Voltage selector insert, fusedrawer and accessory cable
Voltage Selector Systems No. 1-4
Switch position
Switch position
System No. 1
2 separate windings,
one with a tap
3 or 4 switch positions
Switch position
System No. 2
2 separate windings
2 switch positions
Switch position
System No. 3
3 separate windings
3 or 4 switch positions
System No. 4
DPDT
Voltage Selector Insert Order Numbers
1
4
1
2
Voltage markings/switch position
1
2
3
4
without markings
100
120
220
240
110
220
115
230
130
110
240
220
120
240
100
115
230
230
110
230
115
220
110
240
230
220
200
115
230
100
220
115
230
4305.0050.00
4305.0050.02
4305.0050.04
4305.0050.06
4305.0050.12
3
3
3
3
3
without markings
130
110
110
150
110
130
115
4305.0049.00
4305.0049.07
4305.0049.17
4305.0049.19
4
4
4
4
wihout markings
240
240
240
115
230
230
2 (special; .05 stand.)
110
**Insert is specially
designed to block
positions 2 and 3.
2 (special; .05 stand.)
220
*Most common voltage.
Other voltages and custom
voltages require longer
lead times and are subject
to minimum order
quantity.
Voltage selector
System No.
1, 2
1
2
2
1
2
1
2
110
Order Number
*4305.0048.00
*4305.0048.01
*4305.0048.03
*4305.0048.05
4305.0048.08
4305.0048.09
4305.0048.10
4305.0048.11
4305.0048.13
4305.0048.14
4305.0048.15
4305.0048.17
4305.0048.18
**4305.0056.05
220
220
220
230
Schematic
20
Switch position
100
120
110
110
115
115
15
100
115
20
110
110
20
110
110
40
110
110
Fusedrawer
102.
Fusedrawer Order
Order Numbers*
Numbers* (to order fuses, please see page
pgs 97-128.)
2-pole black,
6.3 x 32mm
5 x 20mm
w/shorting bar
(1/4 x 1 1/4")
1-pole black
2-pole black
in the neutral side
1-pole grey
2-pole grey
4305.0006
4305.0001
4305.0021
4305.0017
4305.0012
* Meets tool-only accessibility requirements of medical standards IEC 601-1, BS 5724 part 1, DIN/VDE 0750 part 1
2-pole grey,
w/shorting bar
in the neutral side
4305.0027
Accessory Cable Order Numbers
The accessory cable is optional for voltage selector wiring. Connections must be made by the customer.
Strand = 1.5mm2. Note: To guarantee the minimum air and creepage distances, use taps for the following terminals only:
3/4 or N for KE/CE
2/3/4 or N for KG/CG (concerns voltage selector systems 1, 2 or 3)
Quick-connect terminals
4.8 x 0.8mm
881.0076 (70mm length)
881.0077 (100mm length)
Tap
4.8 x 0.8mm
881.0074 (70mm length)
881.0075 (100mm length)
Power entry
modules type
KE/CE 1-pole
KE/CE 2-pole
KG/CG 1-pole
KG/CG 2-pole
Voltage selector
System No. 1
881.0075
881.0076
881.0074
881.0076
Voltage selector
System No. 2 and 3
881.0074
881.0075
Voltage selector
System No. 4
881.0076
881.0077
2x 881.0074
2x 881.0076
881.0075
881.0076
881.0074
881.0076
881.0074
881.0075
881.0076
881.0077
2x 881.0074
2x 881.0076
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
43
Inlet • Series Parallel Voltage Selector •
8843 AC
Interchangeable Fusedrawer for / x 1 / " or 5 x 20mm Fuses
1
4
1
4
•
•
•
•
•
•
•
•
Power entry module with 1-pole or 2-pole fuseholder
For “cold” connections 65° C, Protection Class I.
Screw-on or snap-in mount from front
Single or double pole shocksafe fuseholder according to
IEC 65/VDE 0860 for 1 /4 x 11 /4" or 5 x 20mm fuses (plug removal
necessary for fuse replacement)
Voltage selector with series parallel connections, 4 switch positions
Solder terminals .118 x .032" (3.0 x 0.8mm)
0.5 Nm torque required for M3 screws for screw-on type
Max. power dissipation according to IEC 127-6 on request. (For
information, see page 5).
UL
CSA
VDE
SEMKO
SEV
Note: Not recommended for new designs. Refer to KE, page 41.
(VDE)
recognition
certification
approval
approval
approval
10A/250V
10A/250V
10A/250V
10A/250V
10A/250V
File #E93617
File #LR38456
File #2096, expert report
File
numbers
on request
Order Numbers (type)
Note: Casing and fuseholders must be ordered separately. To order fuses,
fuses,
please see page
pgs 97-128.
102.
Fuseholder Inserts* (order
8843 casing without switch
2 inserts for 2-pole casing)
1-pole fusing
Mounting
2-pole fusing
8843.1751
(8843-1.751.60)
8843.1761
(8843-1.761.60)
Screw on
8843.0901
(8843-901.60)
for 1/4 x 1 1/4"
(6.3x32mm)
8843.1451
(8843-1.451.60)
8843.1461
(8843-1.461.60)
Snap-in
8843.0902
(8843-902.60)
for 5 x 20mm
Standards: UL 498; CSA C22.2/
182.3; DIN/VDE 0625; SEMKO 9320;
IEC 320/C14; EN 60320
Inlet • On/Off Line Switch • Series Parallel Voltage Selector •
8843 AC
Interchangeable Fusedrawer for / x 1 / " or 5 x 20mm Fuses
1
4
1
4
•
•
•
•
•
•
•
•
•
Note: Not recommended for new designs. Refer to KG, page 42.
(VDE)
Power entry module with 1-pole or 2-pole fuseholder
For “cold” connections 65° C, Protection Class I.
Screw-on or snap-in mount from front
Single or double pole shocksafe fuseholder according to
IEC 65/VDE 0860 for 1 /4 x 11 /4" or 5 x 20mm fuses (plug removal
necessary for fuse replacement)
DPST on/off line switch
Voltage selector with series parallel connections, 4 switch positions
Solder terminals .118 x .032" (3.0 x 0.8mm)
0.5 Nm torque required for M3 screws for screw-on type
Max. power dissipation according to IEC 127-6 on request. (For
information, see page 5).
UL
CSA
VDE
SEMKO
SEV
recognition
certification
approval
approval
approval
10A/250V
10A/250V
10A/250V
10A/250V
10A/250V
File #E93617
File #LR38456
File #2096, expert report
File
numbers
on request
Order Numbers (type)
fuses,
Note: Casing and fuseholders must be ordered separately. To order fuses,
please see page
pgs 97-128.
102.
Fuseholder Inserts* (order
8843 casing with switch
2 inserts for 2-pole casing)
1-pole fusing
Mounting
2-pole fusing
Standards: UL 498; CSA C22.2/
182.3; DIN/VDE 0625; SEMKO 9320;
IEC 320/C14; EN 60320
44
8843.4851
(8843-4.851.60)
8843.4861
(8843-4.861.60)
Screw on
8843.0901
(8843-901.60)
for 1/4 x 1 1/4"
(6.3x32mm)
8843.4451
(8843-4.451.60)
8843.4461
(8843-4.461.60)
Snap-in
8843.0902
(8843-902.60)
for 5 x 20mm
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
FELCOM® Series 64 Power Entry Modules
(VDE)
For “cold” conditions, 65˚ C. Protection class I.
Standards: EN 60320; IEC 320/C14/F; DIN/VDE 0625; SEMKO 9320; CSA C22.2/182.3; UL 498. U.S. Patented
6421.005X.XX
• AC inlet/outlet
• See page 32 for KP
inlet/outlet combination
power entry module,
which can also be
mounted horizontally
A = solder terminals 13.4mm or
quick-connect terminals 17.0mm
6422.005X.XX
• AC inlet
• On/off switch
• See page 32 for KP
inlet/outlet combination
power entry module,
which can also be
mounted horizontally
A = solder terminals 13.4mm or
quick-connect terminals 17.0mm
6423.0X5X.XX
• AC inlet/outlet
• Fuseholder
Plug Removal
Necessary for
Fuse Replacement
A = solder terminals 13.4mm or
quick-connect terminals 17.0mm
6424.0X5X.XX
• AC inlet
• Fuseholder
• On/off switch
Plug Removal
Necessary for
Fuse Replacement
A = solder terminals 13.4mm or
quick-connect terminals 17.0mm
see next page for technical data and ordering instructions
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
45
FELCOM® Series 64 Power Entry Modules, cont'd
(VDE)
6431.005X.XX
• AC inlet/outlet
• On/off switch
A = solder terminals 13.4mm or
quick-connect terminals 17.0mm
6432.0X5X.XX
• AC inlet/outlet
• Fuseholder
• On/off switch
Plug Removal
Necessary for
Fuse Replacement
A = solder terminals 13.4mm or
quick-connect terminals 17.0mm
Order Numbers:
• Snap-in mounting for 1mm – 3mm panel thickness
• Single or double pole shock-safe fuseholder for 5 x 20mm fuses (plug
removal necessary for fuse replacement)
• DPST on/off line switch (non-illuminated)
• Solder terminals .138 x .032" (3.5 x 0.8mm) or quick-connect terminals
.250 x .032" (6.3 x 0.8mm)
• Individual component modules are soldered on a printed circuit board,
fully insulated from the rear
• Shallow depth behind the panel (23mm)
• IEC 320 inlet according to EN 60320, IEC 320/C14
• IEC 320 outlet according to EN 60320, IEC 320/F
• Body: thermoplastic
Terminals: brass, tin-plated
• Max. power dissipation values on request (see pg 5 for
more information).
• For Felcom with line filter, please see Felcom 54 on page 64
Options:
• Other combinations available on request. Contact Schurter, Inc. for part
numbers and minimum order requirements.
• For cord retaining clamp, see page 27
• For mating IEC 320 inlet plugs 4300.0602/0606, see page 23
• For mating IEC 320 outlet plugs 4300.0407/0411, see page 22
• For fuses, see page 102
Approvals:
UL
recognition
CSA
certification
VDE
approval
SEMKO approval
SEV
approval
46
10A/250V
10A/250V
10A/250V
10A/250V
10A/250V
File #E103791
File #LR38456
File #3946, expert report
File
numbers
on request
64 XX.0X5X.XX
Snap-in panel thickness
10
12
15
20
25
30
=
=
=
=
=
=
1.0
1.2
1.5
2.0
2.5
3.0
mm
mm
mm
mm
mm
mm
Terminals
51 = Solder terminals .138 x .032" (3.5 x 0.8mm)
53 = quick-connect terminals .250 x .032" (6.3 x
0.8mm)
Fuseholder
00 = without fuseholder
01 = single pole, for 5 x 20mm fuse
02 = double pole, for 5 x 20mm fuses
Standard combinations
21
22
23
24
31
32
=
=
=
=
=
=
IEC 320 inlet/outlet
IEC 320 inlet, switch
IEC 320 inlet/outlet, fuseholder
IEC 320 inlet, fuseholder, switch
IEC 320 inlet/outlet, switch
IEC 320 inlet/outlet, fuseholder, switch
Base model
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
FELCOM® Individual Components For PCB Mounting
(VDE)
On/off switch – non-illuminated, double pole, single throw (DPST)
Order No.
6050.5510
6050.5512
6050.5515
6050.5520
6050.5525
6050.5530
Panel Thickness
s = 1.0 mm
s = 1.2 mm
s = 1.5 mm
s = 2.0 mm
s = 2.5 mm
s = 3.0 mm
IEC 320 inlet
Order No.
6150.5510
6150.5512
6150.5515
6150.5520
6150.5525
6150.5530
Panel Thickness
s = 1.0 mm
s = 1.2 mm
s = 1.5 mm
s = 2.0 mm
s = 2.5 mm
s = 3.0 mm
Order No.
1-pole
6250.5510
6250.5512
6250.5515
6250.5520
6250.5525
6250.5530
2-pole
6255.5510
6255.5512
6255.5515
6255.5520
6255.5525
6255.5530
Order No.
6650.4510
6650.4512
6650.4515
6650.4520
6650.4525
6650.4530
Panel Thickness
s = 1.0 mm
s = 1.2 mm
s = 1.5 mm
s = 2.0 mm
s = 2.5 mm
s = 3.0 mm
IEC 320 inlet and shocksafe fuseholder – single or double pole, for 5 x 20mm fuses
Plug Removal
Necessary for
Fuse Replacement
Panel
Thickness
s = 1.0 mm
s = 1.2 mm
s = 1.5 mm
s = 2.0 mm
s = 2.5 mm
s = 3.0 mm
IEC 320 outlet
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
47
About Shock Safety for Fuseholders and Power Entry Modules
Miniature Fuses
Miniature Fuses are protective devices for electrically powered apparatus,
small motors, measuring instruments, semiconductors, or assembled circuits. They protect against damage and destruction as a result of unacceptable current loads and short circuits. According to VDE 0820 and IEC 257,
miniature fuses consist of a fuseholder, a fuse, and possibly a bayonet-type
cap (fuse carrier). A distinction is made between open and closed types. The
particular advantage of the closed designs is that there is less risk of electrical
shock both in normal use and while changing the fuse.
Fuseholder Contact Protection According To
IEC 529 Test Finger
Fusedrawer
insertion / removal
Fig.5
Open fuseholder portion of power entry module
Fig.4 and 5
When a 5 x 20 mm or 6.3 x 32 mm (1/4 x 1-1/4") fuse is inserted or
replaced, neither the fuse nor the fuse carrier can come in contact with
any live parts.
Fig.1
Closed fuseholder
Contact System
On conventional fuseholders (bayonet system), momentary discontinuity
frequently occurs when the fuse carrier is pushed. Circuit interruptions of this
kind can mean that stored data on computers, etc., can be erased. But with
the SCHURTER contact system, movements in an axial direction prevent
circuit interruptions.
Fig.2
Open fuseholder
Bayonet-cap (fuse carrier)
5 x 20mm
IEC 529 test finger
Socket
Bayonet-cap (fuse carrier)
6.3 x 32mm (1 /4 x 11 /4")
Fig.3
Open fuseholder portion of power entry module
Fig.2 and 3
It is not possible to touch any live parts on the SCHURTER fuseholder
when the fuse carrier is extracted.
Fuseholder Contact Protection According to
IEC 529 Test Probe
IEC 529 test probe
Fuse carrier
insertion / removal
Fig.4
Open fuseholder
Live parts are completely inaccessible to a probe measuring 1mm in diameter
and 100mm in length (See the FBS series, page 86).
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
3
About Shock Safety For Power Entry Modules, continued
Extra-Safe Medical Fuse Drawers for Power Entry Modules
For added safety, extra-safe fuse drawers are available for the SCHURTER line of power entry modules (with and without mains filters). The drawer can only
be removed with the aid of a tool (e.g. screwdriver) so that opening by hand is virtually impossible. With the KEA series, it is also necessary to pull out the
mains outlet first. Only then can the drawer be removed from the socket. Extra-safe fuse drawers are able to satisfy the following standards and international
specifications: Appliance standard IEC 601-1, BS 5724 part 1, and DIN/VDE 0750 part 1 (suitable for medical applications).
Fig.1
Extra-safe fusedrawer can only
be removed with the aid of a
tool (e.g. screwdriver)
Fig.2
Fingergrip fusedrawer
can be removed by
hand
About Power Dissipation
Power dissipation is the product of voltage drop multiplied by rated current. Power dissipation generates heat. High in-rush and/or higher operating
temperatures can become a problem. Too much heat may lead to melting of the plastic, contact problems, premature failure of the fuse, etc. Therefore, suitable
fuseholders/power entry modules must be selected not only by desired function and application specific requirements, but also by the amount of power
dissipation through the area holding the fuse.
Current ratings for fuseholders/power entry modules vary widely from agency to agency, due to different methods used for temperature rise testing. For the
specifier, it is important to know that the temperature rise testing is performed at UL and CSA using dummy inserts in place of actual fuses. European test
agencies, however, rely on IEC methods that reflect more realistic field conditions. Current ratings provided by the test agency should always be observed.
However, it is imperative that attention also be given to the maximum permissible power dissipation values provided by the manufacturer when selecting a
fuseholder/power entry module.
For further clarification, please refer to the following excerpt from IEC 257 amendment 2, as shown below:
•
Depending upon the type of fuse-link applied in the holder and the possible prolonged overloads of this fuse-link, the contributions to the actual
power dissipation in the holder produced by the contact resistances and the fuse-link may vary considerably.
•
Certain types of miniature fuse-links, covered by IEC Publication 127-2, especially the quick-acting type with high breaking capacity, may sustain
overloads at a level of 1.7 to 2.1 times rated current for a considerable period of time. The application of such fuse-links in closed fuseholders can
under those circumstances result in temperature rises of the holder and its accessible parts, beyond the limits e.g. given in IEC Publication 65: Safety
Requirements For Mains Operated Electronic and Related Apparatus For Household and Similar Use.
Attention should therefore be given to the possibility of a dangerous situation arising out of such overloads.
MAXIMUM POWER DISSIPATION VALUES
Ambient temperature +23˚C (±0.1) according to IEC 127-6
Fuseholders
LEGEND
5 X 20mm =
1
/ 4 x 11/ 4" =
Quick-connect
terminals
Pcb terminals
Tamb
Values are determined at ambient temperatures ranging from +20˚C to +80˚C
4
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
About Power Dissipation, continued
Fuseholders
LEGEND
5 X 20mm =
1
/4 x 11/4 " =
Tamb
Values are determined at ambient temperatures ranging from +20˚C to +80˚C
Power Entry Modules
LEGEND
2 Pole =
1 Pole =
Tamb
KP / GSF1 / GSF2
5 x 20
Values are determined at ambient temperatures ranging from +20˚C to +80˚C
Power Entry Modules
LEGEND
2 Pole =
1 Pole =
Tamb
Values are determined at ambient temperature +23˚C. Values at a higher ambient temperature on request.
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
5
Accessories For AC Inlets, Plugs and Power Entry Modules
Insulation Cover for
AC Inlets, Outlets and
Power Entry Modules
KG
KD
KE
KEC
KEB (2-pole)
KEB (1-pole)
KEA
Series 6200
Series 6600
Series 6100
Technical Data:
• Material: flexible plastic PVC
• Surface resistance: 7.8 x 10 8 Ω at 23˚ C, 63% humidity
• Easily mountable from back side
• Oxygen Index Rating: 30 (tested by Cookson Labs)
Based on the Oxygen Index Rating, material qualifies for UL 94V-O
Order Numbers
Order No.
Series
0859.0047
KG / CG with or without bowden cable
0859.0047
CD with or without bowden cable
0859.0075
CE all part numbers
0859.0072
Series 6100 / 6102 / 6110 / 6120
0859.0074
Series 6200 / 6202 / 6220 / 6600
0859.0076
Series
KEA (except pcb mount type)
KEB (1-pole) all part numbers
KEB (2-pole) all part numbers
KEC / KFC all part numbers
KD with or without bowden cable
KE all part numbers
Order No.
0859.0109
0859.0077
0859.0108
0859.0048
0859.0047
Cord Retaining Clamp (to prevent loosening or accidental removal)
0888.0001
Clamp with hexnuts
Drawing for 0888.0004/0005
only: Clamp with hexnuts
For filter type:
nominal size +0.5mm
Selection Chart for Cord Retaining Clamp
Order No.
KE / CE
KG / CG
KFS / KFX
FELCOM 54 / 64
5100 screw-on
5110 screw-on
5200 screw-on
5220 screw-on
6100 screw-on
6100 snap-in
3
3
3
3
1
3
1
1
2
2
1
3
4300.0603
4300.0407
4
2
3
2
3
6600 screw-on
KD / CD
3
6220 snap-in
KEC / KFC
2
6220 screw-on
KEB II / KFB II
3
6200 snap-in
KEB I / KFB I screw-on
2
6200 screw-on
KEB I snap-in
3
6110 snap-in
KEA / KFA screw-on
4300.0602
Inlet
6110 screw-on
Plug
KEA snap-in
Select desired inlet and plug. Match corresponding number to legend at right to identify retaining clamp order number.
1
0888.0001
2
0888.0004
3
0888.0005
4
0888.0015
5
0888.0016
6
0888.0017
5
6
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
27
PLUGS AC Inlets for Cable Connections
(VDE)
•
•
•
•
•
4300.0407
4300.0411
Standards: EN 60320;
IEC 320/E
For “cold” connections 65˚C, Protection Class I
AC inlet plugs with straight or 90˚ cable entry
Max. wire size 18 AWG (1.0 mm2)
Disassemble plug for cable connection
Material: thermoplastic, UL 94V-O
Prongs and terminals: brass, tin-plated
4300.0407 / .0411:
UL
recognition
CSA
certification
VDE
approval
SEV
approval
10A/250V
10A/250V
10A/250V
10A/250V
File #E96454
File #LR74853
File #95403,expert report
File number on request
4300.0401:
UL
recognition
CSA
certification
SEV
approval
10A/250V
10A/250V
6A/250V
File #E96454
File #LR70111
File number on request
4300.0401
4300.0407
4300.0401
4300.0411
Order Numbers (type)
Inlet plug
4300.0407
4300.0411
4300.0401
22
(8143)
(8143.A)
(P685)
Cable Entry
straight (in plug axis)
angled (90˚ to plug axis)
angled (90˚ to plug axis)
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
PLUGS AC Outlets for Cable Connections
®
• For “hot” or “cold” connections 120˚C or 65˚C, Protection Class I
• AC outlet plugs with straight or 90˚ cable entry
4300.0602 / .0606 / .0609 (65˚C):
• Max. wire size 18 AWG (1.0 mm2)
• Disassemble plug for cable connection
• Material: thermoplastic, UL 94V-O
(4300.0609 UL 94V-2)
Contact material: brass, nickel-plated
4300.0602
4300.0606
UL
CSA
VDE
SEMKO
SEV
recognition
certification
approval
approval
approval
4300.0602
10A/250V * File #E96454
10A/250V * File #LR70111
10A/250V File #63826
File
10A/250V
numbers
10A/250V
on request
4300.0606 / 0609
File #E96454
File #LR70111
File #69635
File
numbers
on request
*4300.0609: 15A/125V, 10A/250V UL, CSA
4300.0603
4300.0603 / .0607 (120˚C):
• Max. wire size 16 AWG (1.5 mm2)
• Disassemble plug for cable connection
• Material: thermoplastic, UL 94V-2
Contact material: brass
4300.0607
UL
CSA
VDE
SEMKO
SEV
OVE
NEW
4300.0609
listing
certification
approval
approval
approval
approval
15A/250V
15A/250V
10A/250V
10A/250V
10A/250V
10A/250V
File #E96454
File #LR38456
File #73759
File
numbers
on request
Standards: EN60320; IEC 320/C13/C15
4300.0602
4300.0606
4300.0609
4300.0603
4300.0607
Order Numbers (type)
Outlet plug, 65˚C
4300.0602
(P587)
4300.0606
(P587SE)
4300.0609
(SF0430)
Outlet plug, 120˚C
4300.0603
(8943.W)
4300.0607
(8943.L.W)
Cable Entry
straight (in plug axis)
angled (90˚ to plug axis)
angled (90˚ to plug axis)
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
23
Selector Chart for Power Entry Modules with Line Filter
For power entry modules
without filter, see page 29
Snap in or
screw mount
NEW
EMI shield
NEW
Filter or surge
protector
Series / page number
KFS/5100, page 52
GRF4, page 53/54
KPF / KPS, page 55
KFB, page 56
KFB, page 56
Rated current / voltage
1A – 10A / 250V
1A – 10A / 250V
1A – 10A / 250V
1A – 6A / 250V
1A – 6A / 250V
•
•
• with or without outlet
•
•
•
•
AC inlet
Fuseholder (5 x 20mm)
• optional
On/off line switch
• optional
Series / page number
5200, page 57
5220, page 57
KFA, page 58
8843, page 59
KFC, page 60
Rated current / voltage
1A – 6A / 250V
1A – 6A / 250V
1A – 6A / 250V
1A – 10A / 250V
1A – 6A / 250V
•
•
•
•
AC inlet
•
•
•
Fuseholder (5 x 20mm)
•
•
•
Fuseholder
(5 x 20mm or 1/4 x 11/4" fuses)
Voltage selector
• step
• step
Felcom
RFI filter only
Series / page number
CD, page 61
CE, page 62
CG, page 63
Felcom, page 64
Filter only, page 64
Rated current / voltage
1A – 6A / 250V
1A – 6A / 250V
1A – 6A / 250V
1A – 6A / 250V
1A – 6A / 250V
•
•
•
• with or without outlet
•
•
•
• series/parallel
• series/parallel
AC inlet
Fuseholder (5 x 20mm)
Fuseholder
optional
(5 x 20mm or 1/4 x 11/4" fuses)
On/off line switch
•
Voltage selector
• step
•
optional
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
49
About Line Filters
Field of Application
The increasing use of electronic circuitry in many technical fields made it
necessary to protect these sensitive control systems from external
interference. For this purpose, special mains filters have been developed.
These filters eliminate or minimize interference to guarantee the function
of electronic equipment.
Possible Interference
Class Y Capacitors are intended for an operation voltage Veff =250 V with
increased electrical and mechanical safety and limited capacity.
b) Leakage current according to IEC 335.T. 1
The leakage current of a device is mainly determined by the capacitance
value of the Y-capacitor. According to international standards IEC 335-1
and VDE 0700 T.1., the following regulations with respect to leakage
current can be assumed:
In practice, mains interference can be divided into four categories:
A. Fluctuation of the mains voltage (magnetic stabilizer).
B. Harmonic wave interference in the frequency range 100 Hz-2 kHz
(selective harmonic filter type).
C. Transient interference signals in the frequency range up to 300 MHz
(low pass filter type)
D. Sinusoidal interference signals in the frequency range up to 1 GHz
(broad band, low pass filter type)
For electrical household appliances
Portable appliances
to Protection class I
0.75 mA
Stationary motor appliances *
to Protection class I
3.5 mA
Stationary heating appliances
to Protection class I
5
From a practical point of view, the main types of interference are those in
the last two categories, C and D, superimposed upon the mains. Such
interference may adversely affect or even destroy electronic circuits.
Appliances
to Protection class II
0.25 mA
Unshielded appliances
5
Function of the Mains Filter
Others
3.5 mA
An optimum rated mains filter can readily perform a double function
(Fig.1).
mA
mA
* Stationary appliances fixed or weighing in excess of 18 kg (without carrying handle)
For other applications
Ref.
Analytical
Medical
EDV
Calculators
Instruments
UL
0.5 mA
(UL 1262)
0.1 mA
(UL 544)
5.0 mA
(UL 478)
5.0 mA
(UL 114)
5.0 mA
(UL 1244)
IEC
-
0.1 mA
(IEC 62A)
3.5 mA
(IEC 435)
0.5 mA
(IEC 380)
3.5 mA
(IEC 348)
Fig. 1. Double function of a mains filter, acts in both directions.
Function 1
The filter protects the electronic control circuit from voltage spikes on the
mains input that can be generated by, for instance, electromechanical
switches and relays.
Function 2
The same filter also acts in the opposite direction. These can attenuate
interference variables to such an extent that the admissible level of
interference can be attained.
c) Rated voltage U n ; Rated current In
For each filter type, the rated voltage and the rated current are specified in
the technical data sheet. The indicated rated currents refer to the full load
(In) at an ambient temperature of 45˚C. At higher temperatures, the
allowable maximum rated current decreases linearly to 0 amp at a
temperature of 85˚C.
Amp.2
In2
Filter Construction and Combination
SCHURTER mains filters are always available together with standard
appliance inlets, or with a combination of inlet, fuse holder, switch and
voltage selector. Following criterion are of essential importance:
a) Radio interference suppression capacitors
All SCHURTER filters are equipped with radio interference suppression
capacitors, either Class X or Class Y, according to international standards
requirements of IEC. As a rule, they are self healing metal-paper types,
which are tested according to the standards of the major user countries,
and which are accepted as noise suppression capacitors.
Class X capacitors have unlimited capacity for those applications in which
a failure caused by a short circuit cannot result in a dangerous electrical
shock.
50
Tamb
45˚C (40˚C)
85˚C
Permissible working current as a function of ambient temperature
d) Insertion transmission loss (asymm., and symm.)
In the case of asymmetric measurement, the line and neutral conductors
are measured together with respect to earth (Fig. 2).
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
About Line Filters, continued
Test Sample
Four poles
Attenuator
Fig. 2. Asymmetric measurement: line (L) and neutral (N) are
measured together with respect to earth (E).
Fig. 5. Substitution method for measurement of insertion transmission loss
In the case of symmetric measurement, the insertion transmission loss is
measured between the line and neutral through a balancing transformer.
The earth wire is not used (Fig. 3).
f) Dielectric strength
To date the dielectric strength has been tested according to the Ycapacitor specification. VDE 0563 T.3 specifies this test as per the
following table:
Capacitor
Class X
Class Y
Fig. 3. Four pole network with integrated balanced transformer for the
measurement of insertion transmission loss in the symmetrical case.
e) Measurement method
The insertion transmission loss D is defined as that loss which is
developed when a four pole network is inserted into an existing set-up,
having a surge impedance Z. Using the assumption that the LHS as well
as the RHS terminal impedance of the four pole network are of the same
real value, the insertion transmission loss and the overall loss are the
same.
The insertion transmission loss, calculated in decibels, can be obtained as
follows:
D = 20 log
Type test
Ceramic and foil capacitors
Up – = 4.3 Un
Self healing capacitors (MP)
Up ~ = 2.15 Un
All capacitors
Up ~ = 1500 V
Between plate and case
Up ~ = 2 Un + 1500V
Impulse voltage test
in Germany none
Standards and Approvals
SCHURTER mains filters according to international quality standards are
approved or in test at all major laboratories such as UL, CSA, VDE,
SEMKO, SEV and DEMKO.
The following mains filters qualify for use in equipment according to IEC
950, IEC 664 Installation Category I & II: KFS, KFB, KFA, KFC, CD, CE
and CG.
Development and Manufacturing
UG
2 U2
In practice, the substitution method is used exclusively. Its main
advantage is that the absolute value of the voltage needs not to be known
(Fig. 5).
All SCHURTER mains filters are designed and developed in cooperation
with a major filter manufacturer, ensuring that technical as well as quality
requirements are optimally fulfilled. Parts for the mains filters with
appliance plugs are manufactured both by Schurter and our mains filter
partner. The know-how of both partners can thus be used for the benefit of
the product performance.
Consulting, Laboratory Tests
If you have a particular application not mentioned in this catalog, feel free
to contact SCHURTER at one of the numbers listed below. We can
perform technical tests and if necessary, also specific laboratory
measurements. The measurements can either be simulated or performed
directly on your equipment.
Fig. 4. Four pole network with real termination
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
51
KFS / KFX / 5100 / 5110 Line Filter with AC Inlet
• For cold connections 65˚ C, Protection Class I
• KFS/KFX qualifies for use in equipment with safety requirements acc.
to IEC 950, IEC 664 Installation Category I & II (KFS) and III (KFX)
• Screw mount from front or rear, or snap-in mount from front
• Quick-connect terminals .250 x .032" (6.3 x 0.8mm)
• 0.5 Nm torque required for M3 screws
• For attenuation graphs, see page 66
• For general information on filters, see page 50
• For materials, options and accessories, see page 30
• For ac inlets without RFI filter, see page 8
5100 / 5110
KFS / KFX
Recommended for IEC 950
equipment requirements
UL
CSA
VDE
SEMKO
SEV
Standard or
Medical Filter
recognition 1A-10A/250V *
certification 1A-10A/250V *
approval
1A-10A/250V *
approval
1A-10A/250V *
approval
1A-10A/250V *
*5100 Series rated only 1A-6A
Standards: UL 1283; CSA C22.2/8; DIN/VDE 0565; IEC 320/C14; EN 60320
File #E72928
File #LR725591) / LR97784-12)
File #588241) / 531552)
File numbers
on request
1)
KFS/KFX
2)
5100/5110
L
N
KFS / KFX
5100 / 5110
Cy
E
Cx
Cy
L (P)
L = 59mm (5100, long type)
50mm (5110, short type)
Schematic for
KFS/KFX/5100/5110
Order Numbers
KFS / KFX with standard RFI filter
KFS
KFX
In (A)
Tamb 45˚ C *
4300.5051
4300.5052
4300.5061
4300.5062
1
2
4300.5053
4300.5063
4
4300.5054
4300.5064
6
4300.5055
4300.5065
10
Un (V)
up to
250V
max.
50/60 Hz
Max. leak. curr.
@ 250V/50 Hz
Cx2
(nF)
Cx1
(nF)
Cy
(nF)
L(mH)
+50/-30%
< 0.5 mA
< 0.5 mA
47
47
2 x 2.2
2 x 2.2
2 x 10
2x4
(KFS
only)
(KFX
only)
2 x 2.2
2 x 1.5
2 x 2.2
2 x 0.8
2 x 2.2
2 x 0.16
< 0.5 mA
< 0.5 mA
< 0.5 mA
Test voltage
L, N E
L
2000V
50 Hz
2 sec.
N
1700V
DC
2 sec.
Surge voltage
immunity
For KFX only:
Cy: L,N E 4000Vp
1.2/50µs
Cx1: L, N 4000Vp
1.2/50µs
VDE Tamb 40˚C; values of fuses (time-lag): Isi ≤ In
5100 / 5110 with standard RFI filter
5100 (long type)
Screw-on
5100.0133.1
5100.0233.1
5100.0433.1
5100.0633.1
5110 (short type)
Screw-on
5110.0133.1
5110.0333.1
5110.0633.1
5110.1033.1
(5100-1-33)
(5100-2-33)
(5100-4-33)
(5100-6-33)
Snap-in 0.8-3.0mm
5100.0143.1
(5100-1-43)
5100.0243.1
(5100-2-43)
5100.0443.1
(5100-4-43)
5100.0643.1
(5100-6-43)
In (A)
Tamb 40˚C
1A
2A
4A
6A
Un(V)
up to
250V
max.
50/60 HZ
Max. leakage curr.
@250V/50 HZ