T9-311
Thermal (T- and TA-Line)
www.schurter.com /PG17_18_19
Circuit Breaker for Equipment thermal, Threaded-neck type, 1 pole
T9-311: Threaded neck type with nut nickelplated
Description
- Threaded neck type
- Thermal circuit breaker
- 1‑pole
- On request available with elevaled glow-wire ratings
- Quick connect terminal 6.3 x 0.8 mm
Unique Selling Proposition
- Reset type
- Cycling trip-free release
- Compact design
- Different mounting possibilities
Applications
- Designed for standard and medical applications
- Power supplies
- Uninterruptible power supply
- Power tools
- Industrial appliances
- HVAC
- Household appliances
Weblinks
pdf datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, DistributorStock-Check, Detailed request for product, Product News
Standards
- Approval Reference Type: T9
- IEC 60934
- UL 1077
- CSA C22.2 No. 235
- GB 17701
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current
Conditional short circuit capacity
␣
240 V, 50 / 60 Hz
48 / 32 V, see approvals
3-16 A, see approbations
IEC: Inc, PC1, AC 240 V: 2 kA
Ambient temperature
␣
␣
Weight
3 A: -5 °C to 60 °C
4 A: -5°C to 50 °C
5-16 A: -5 °C to 60 °C
9 - 13 g
UL / CSA: SC, AC 240 V DC 48 / 32 V:
2 kA, C1
Degree of protection front side IP 40
Endurance minimum
IEC: 200% Ir, cos φ 0.6: min. 50 switching cycles
Endurance typical
3-8 A: 150% Ir, cos φ 0.9:
2500 switching cycles
␣
10-16 A: 150% Ir, cos φ 0.9:
6000 switching cycles
Dielectric Strength
1500 VAC
Insulation Resistance
500 VDC > 1000 MΩ
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in General Product
Information
Circuit Breakers
1
T9-311
Thermal (T- and TA-Line)
www.schurter.com /PG17_18_19
Dimension [mm]
T9-211/311
36.1
10
19
8.6
8
5
6.3x0.8
19
10.4
SW14
±0.2
13.6 ±0.2
ø 15.4
3/8" -27UNS
Pannel thickness s = 0.8 - 5.5 mm
+0.10
0.00
8.90
9.6
9.6
Cover TZZ31für IP65 optional, see accessory
17
SW 14
Hexagonal nut TZZ12 / TZZ51
3/8" -27UNS
Approval
2.5
13.6
Rated current
Rated voltage AC
Rated voltage DC
UL 1077
3 - 12 A
14 - 16 A
240 V
240 V
48 V
32 V
CSA 22.2 235
3 - 12 A
14 - 16 A
240 V
240 V
48 V
32 V
IEC 60934
3 - 12 A
14 - 16 A
240 V
240 V
48 V
32 V
GB 17701
3 - 12 A
14 - 16 A
240 V
240 V
48 V
32 V
Typical internal resistance
Rated Current [A]
Internal Resistance [mΩ]
3
65.0
4
21.6
5
23.6
6
16.3
7
15.3
8
12.9
10
7.3
12
7.0
14
4.8
15
4.3
16
3.9
2
Circuit Breakers
T9-311
Thermal (T- and TA-Line)
www.schurter.com /PG17_18_19
Time-Current-Curves
[min]
[min]
[sec]
10'000
[sec]
10'000
T9
T9
5 A -16 A (TC-1)
60
4A
(TC-2)
30
20
1'000
10
10
5
5
3
1'000
3
Time in Seconds
100
1
10
100
1
10
1
2
1.35
1.45
1.05
0.1
1
1
3
4
5
6
7
8
0.1
1
10
1.5
Time in Seconds
(TC-2)
30
1.05
20
3 A
60
2
Multiple of Rated Current In
Multiple of Rated Current In
Reference Temperature +23°
Reference Temperature +23°
3
4
5
6
7
8
10
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient temperature [°C]
Correction factor
-5
0,85
+10
0,95
+23
1,00
+40
1,08
+60
1,21
Example: Rated current = 10 A; Environmental temperature = 60 °C; --> Correction factor
= 1.21; Resulting current = 12.1 A --> Fount to next higher rated current: 13 A
Accessory
Part Number
Type
Resources / Description
4404.0039
TZZ31
Protection cover for IP 65
4400.0420
TZZ11
Knurled nut nickel-plated
4400.0559
TZZ11-414
Knurled nut black
4400.0425
TZZ12
Additional hexagonal nut nickel-plated
4404.0072
TZZ51
Additional hexagonal nut PA 66
Variants
Mounting
Front printing
Rated current
Order Number
Threaded-neck type
Rated current not printed on front
3.0 A
4404.0049
█
Threaded-neck type
Rated current not printed on front
4.0 A
4404.0019
█
Threaded-neck type
Rated current not printed on front
5.0 A
4404.0025
█
Threaded-neck type
Rated current not printed on front
6.0
4404.0020
█
Threaded-neck type
Rated current not printed on front
7.0 A
4404.0027
Threaded-neck type
Rated current not printed on front
8.0 A
4404.0021
Circuit Breakers
█
3
T9-311
Thermal (T- and TA-Line)
www.schurter.com /PG17_18_19
Mounting
Front printing
Rated current
Order Number
Threaded-neck type
Rated current not printed on front
10.0 A
4404.0022
█
Threaded-neck type
Rated current not printed on front
12.0 A
4404.0023
█
Threaded-neck type
Rated current not printed on front
14.0 A
4404.0026
█
Threaded-neck type
Rated current not printed on front
15.0 A
4404.0028
█
Threaded-neck type
Rated current not printed on front
16.0 A
4404.0024
█
█ Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
100 Pcs
08.06.2017
Packaging Unit
4
Circuit Breakers
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
很抱歉,暂时无法提供与“4404.0049”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+22.68630
- 7+18.78150
- 18+17.75140
- 国内价格
- 1+74.86731
- 7+39.41311
- 15+28.68007