0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
4410.0565

4410.0565

  • 厂商:

    SCHURTER

  • 封装:

  • 描述:

    CIR BRKR THRM 11A 240VAC 28VDC

  • 数据手册
  • 价格&库存
4410.0565 数据手册
T12-211 Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Circuit Breaker for Equipment thermal, Threaded neck type, Reset type, Quick connect terminals See below: Approvals and Compliances Description Applications Unique Selling Proposition References Weblinks - Threaded neck type - Thermal circuit breaker - 1‑pole - Reset type - Quick connect terminals 6.3 x 0.8 mm - Compact design - Positively trip-free release - Available with cover - Different mounting possibilities pdf data sheet, html datasheet, General Product Information, DistributorStock-Check, Detailed request for product, Product News Technical Data Rated Voltage AC Rated Voltage DC Rated current range AC Conditional short circuit capacity Inc Short circuit capacity Icn Degree of Protection Dielectric Strength Insulation Resistance Endurance typical Endurance minimum - Power supplies - Uninterruptible power supply - Power tools - Household appliances   AC 240 VAC 28 VDC 0.05 - 15/16 A , see approbations IEC 60934: PC1, AC 240 V: 1 kA  IEC 60934: at In < 7 A/240 VAC : 8 x In  IEC 60934: at In ≥ 7 A/240 VAC : 200 A  AC/DC 28 V : 400 A  front side IP40 acc. to IEC 60529 50 Hz: > 1.5 kV Impulse 1.2/50 μs: > 2.5 kV 500 VDC > 100 MΩ 2 x Ir: 5000 switching cycles Reset type   AC : 2 x Ir , cos φ 0.6 :   DC : 2 x Ir , L/R = 2 - 3 ms :   50 switching cycles Overload ␣ Allowable Operation Temp. Vibration Resistance Shock Resistance Tripping Type Actuation Type Weight IEC: min. 40 trips @ 6 x Ir, cos φ 0.6 UL / CSA: min. 50 trips @ 1.5 x Ir, cos φ 0.75 -5 °C to 60 °C ± 1.5 mm @ 10 - 60 Hz acc. to IEC 60068-2-6, test Fc 10 G @ 60 - 500 Hz acc. to IEC 60068-2-6, test Fc 100 G / 6 ms acc. to IEC 60068-2-27, test Ea Thermal  Reset type  ca.  10 g Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. Circuit Breakers 1 T12-211 Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: T12 Approval Logo Certificates Certification Body Description VDE Approvals VDE VDE Certificate Number: 99673 UL Approvals UL UR File Number: E71572 CCC Approvals CCC CCC Certificate Number: 2020970307003504 Design Standard Description Designed according to IEC 60934 Circuit-breakers for equipment (CBE) Designed according to UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment Designed according to CSA C22.2 No. 235 Supplementary Protectors Designed according to GB 17701 Circuit-breaker for equipment Design Standard Description Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. UKCA declaration of conformity SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Product standards Product standards that are referenced Organization Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification 2 Circuit Breakers T12-211 Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Dimension [mm] T12-211 3/8-27UNS-2A Ø 5.7 48.5 – 0.2 +0.5 10 18 14.7 8.8 1 2 2 11.5 24.6 31– 0.2 14 14.5 SW T12-211SN 4 6 5 3/8-27UNS-2A Ø 5.7 57.5 57. 5 +0.5 48.5 – 0.2 10 18 14.7 8.8 1 A 6.3 2 2 3 2.5 20.2 24.6 31– 0.2 14 14.5 SW Circuit Breakers 3 T12-211 Thermal (T- and TA-Line) https://www.schurter.com /PG17_20   16 Ø 16 6 9. 8.9 Diagrams T12-... T12-...N 1 1 2 2 T12-...S T12-...SN Approval 4 3 1 54 2 6 1 54 2 3 6 Main circuit Auxiliary circuit Rated current Rated Voltage AC Rated Voltage DC Rated current Rated Voltage AC Rated Voltage DC UL 1077 CSA C22.2 No. 235 0.05...15 A 240 V 28 V 2A 3A 120 V - 28 V CSA C22.2 No. 235 0.3...16 A 240 V 28 V 1A 240 V - IEC 60934 0.05...16 A 240 V 28 V 1A 240 V 28 V GB 17701 0.05...16 A 240 V 28 V 1A 240 V 28 V Circuit Breakers T12-211 Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Typical internal resistance per pole Rated Current [A] Internal Resistance [Ω] 0.05 225.000 0.50 3.300 1.00 0.880 2.00 0.267 3.00 0.128 4.00 0.073 5.00 0.040 6.00 0.031 7.00 0.018 8.00 0.018 9.00 0.010 10.00 0.0087 11.00 0.0087 12.00 0.0087 13.00 0.0087 14.00 0.0070 15.00 0.0070 16.00 0.0055 Effect of ambient temperature The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: Ambient Temperature [°C] Correction factor -5 0.87 0 0.90 10 0.95 23 1.00 30 1.05 40 1.12 50 1.20 60 1.30 Example: Rated current = 5 A, Environmental temperature = 50 °C, --> Correction factor = 1.2, Resulting current = 6.0 A Circuit Breakers 5 T12-211 Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Time-Current-Curves [ min ] [ sec] 10'000 < 7,0 A > 7,0 A 60 30 20 2´000 1´000 10 500 5 200 Time in Seconds 100 1 50 20 10 5 2 1 0, 5 0, 3 0, 2 0, 1 1,05 1,32 2 3 4 5 8 10 Multiple of Rated Current In Ambient temperature +23° Config. Code T12|-|1|2|3|A|B|C|-|1.23|  The characters are placeholders for the correspondingly keys of selections from the key tables. T12|-| 1 |2|3|A|B|C|-|1.23| = Mounting Mounting Setting indication Configuration key Threaded neck type with hexagonal- and knurled nut 2 T12|-|1| 2 |3|A|B|C|-|1.23| = Actuation Type Actuation Type 1 T12|-|1|2| 3 |A|B|C|-|1.23| = Terminal Terminal Configuration key Quick connect terminal 6.3x0.8mm 1 T12|-|1|2|3| A |B|C|-|1.23| = Auxiliary contact Auxiliary contact Configuration key Auxiliary contact S T12|-|1|2|3|A| B |C|-|1.23| = Shunt terminal Shunt terminal Configuration key Shunt terminal N T12|-|1|2|3|A|B| C |-|1.23| = Setting indication 0.05 A Circuit Breakers Configuration key 0.05 0.1 A 0.1 0.15 A 0.15 0.2 A 0.2 0.3 A 0.3 0.4 A 0.4 0.5 A 0.5 0.6 A 0.6 0.7 A 0.7 0.8 A 0.8 0.9 A 0.9 1.0 1 1.1 A 1.1 1.2 A 1.2 1.3 A 1.3 1.4 A 1.4 1.5 A 1.5 1.6 A 1.6 1.7 A 1.7 Other rated currents on request 6 R T12|-|1|2|3|A|B|C|-| 1.23 | = Rated current Rated current Configuration key Reset type Setting indication Configuration key T12-211 Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Rated current Configuration key Rated current Configuration key 1.8 A 1.8 6.5 A 1.9 A 1.9 7.0 A 7 2.0 A 2 7.5 A 7.5 2.1 A 2.1 8.0 A 8 2.3 A 2.3 8.5 A 8.5 2.5 A 2.5 9.0 A 9 2.8 A 2.8 9.5 A 9.5 3.0 A 3 10.0 A 10 3.3 A 3.3 11.0 A 11 3.5 A 3.5 12.0 A 12 4.0 A 4 13.0 A 13 4.5 A 4.5 14.0 A 14 5.0 A 5 15.0 A 15 5.5 A 5.5 16.0 A 16 6.0 6 6.5 Other rated currents on request Other rated currents on request Variants Rated Current [A] Construction variants Auxiliary contact 0.8 Shunt terminal Config. Code Order Number T12-211S-0.8 4410.0044 Setting indication l 1 l T12-211SNR-1 4410.0655 2.5 l T12-211S-2.5 4410.0046 6.5 l T12-211S-6.5 4410.0264 10 T12-211-10 4410.0106 12 T12-211-12 4410.0019 l l █ █ Most Popular. Availability for all products can be searched real-time: https://www.schurter.com/en/info-center/supporttools/stock-check-distributors Packaging Unit   20 Pcs  Accessories Description T-Line_Accessories Accessories to T-Line 27.03.2024   The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. Circuit Breakers 7
4410.0565 价格&库存

很抱歉,暂时无法提供与“4410.0565”相匹配的价格&库存,您可以联系我们找货

免费人工找货