4420.0176

4420.0176

  • 厂商:

    SCHURTER(硕特)

  • 封装:

  • 描述:

    CBE AS168X-ACBH2

  • 数据手册
  • 价格&库存
4420.0176 数据手册
AS168X Add-on modules Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 Signal contact Relay trip module OU Auxiliary contact T Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic See below: Approvals and Compliances Description Technical Data AC 277 V / 6 A (50/60 Hz)  DC 125 V / 1 A  DC 50 V / 6 A  IEC: Inc, PC1, AC 277 V: 1 kA  50 Hz: > 2 kV Impulse 1.2/50 μs > 5 MΩ mechanical: 50000 switching cycles IEC 60947-5-1   AC : 10 x Ir , p.f. = 0.3 :   DC : 1 x Ir , L/R = 0.3 s :   6050 switching cycles AS ␣ - Industrial appliances References Last order possibility: 31.08.2018 Last delivery date: 30.09.2018 Weblinks pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Detailed request for product, Product News   Ratings ␣ ␣ Conditional short circuit capacity Dielectric Strength Insulation Resistance Endurance typical ␣ Applications E- - DIN-Rail Mounting - Auxiliary contact module Each auxiliary contact module contains one contact, either normally open or normally closed - Signal contact module Signal contact modules are linked internally with the protected poles but not linked at the handles. Contacts are actuated by a fault condition at the protected poles, not by manual operation of the CBE - Relay trip module The relay trip module can be used for remote tripping of the adjacent poles by applying a voltage to the module's terminal Overload ␣ Ambient temperature Vibration Resistance Shock Resistance Degree of Protection Weight AC: min. 10 trips @ 10 x Ir, p.f. = 0.3 DC: min. 50 trips @ 1.1 x Ir, L/R = 0.3 s -20 °C to 60 °C ± 0.75 mm @ 10 - 60 Hz acc. to IEC 60068-2-6, test Fc 10 G @ 60 - 500 Hz acc. to IEC 60068-2-6, test Fc 30 G / 18 ms acc. to IEC 60068-2-27, test Ea from front side IP 20 acc. to IEC 60529 22 - 49 g  AC : 26 A / 2.6 A , p.f. = 0.35 :   DC : 1.1 A / 1.1 A , L/R = 0.3 s :   6000 switching cycles Approvals and Compliances PH Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in   Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: AS168X Approval Logo Certificates Certification Body Description VDE Approvals VDE VDE Certificate Number: 40021845 UL Approvals UL UL File Number: E216629 / E71572 UL Approvals UL UL File Number: E216629 / E71572 Circuit Breakers 1 AS168X Add-on modules Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 Product standards Product standards that are referenced Standard Description Designed according to IEC 60947-5-1 Circuit-breakers for equipment (CBE) Designed according to UL 508 Standard for Supplementary Protectors for Use in Electrical Equipment Designed according to UL 508 Standard for Industrial Control Equipment Designed according to CSA C22.2 Supplementary Protectors T Design Application standards Application standards where the product can be used Design Standard Designed for applications acc. IEC/UL 60950 Description Compliances The product complies with following Guide Lines Details Initiator Description CE declaration of conformity SCHURTER AG RoHS SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. EU Directive RoHS 2011/65/EU E- Identification IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. China RoHS REACH Dimension [mm] The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. AS   SCHURTER AG AS168X-ACBH. PH +0.5 17.5 - 0.0 2 Circuit Breakers AS168X-ACBA. 90 90 AS168X-ACBS. +0.5 17.5 - 0.0 90 Organization OU Organization +0.5 17.5 - 0.0 AS168X Add-on modules Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20   AS168X-Auxiliary contact 35.7 90 A) 5.1 T 37.1 26.4 44.4 OU 68.4 61.6 45 +0.5 8.75 - 0.0 A) 35 mm DIN rail EN 50022 60 Diagrams AS168X-CB1... / AS168X-ACBH2 AS AS168X-CB1... / AS168X-ACBH1 E- 75.6 AS168X-CB1... / AS168X-ACBS2 PH AS168X-CB1... / AS168X-ACBS1 Circuit Breakers 3 AS168X Add-on modules Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 Approvals Relay trip module Standard Rated voltage AC Rated voltage DC UL 508 CSA C22.2 no. 14 - - UL 1077 up to 277 V up to 240 V - - EN 60934 - - GB 17701 - - Standard Rated current AC UL 508 CSA C22.2 no. 14 6A UL 1077 6A CSA C22.2 no. 235 - EN 60934 6 A (Ac-15) GB 17701 - Symbol Approvals Signal contact Symbol Standard UL 508 CSA C22.2 no. 14 UL 1077 CSA C22.2 no. 235 Rated current DC Rated voltage DC 277 V 1A 6A 125 V 50 V 277 V 1A 6A 125 V 50 V - - - 277 V 1 A (DC-12) 0.5 A (DC-13) 6 A (DC-12) 125 V 125 V 50 V - - - Rated current AC Rated voltage AC Rated current DC Rated voltage DC 6A 277 V 1A 6A 125 V 50 V 6A 277 V 1A 6A 125 V 50 V - - - - 6 A (AC-15) 277 V 1 A (DC-12) 0.5 A (DC-13) 6 A (DC-12) 125 V 125 V 50 V - - - AS EN 60934 Rated voltage AC E- Approvals Auxiliary contact OU CSA C22.2 no. 235 T Symbol GB 17701 - Add-on modules Type H1 assumes the same contact position Type H2 assumes the opposite position Actuation of the contact is determined by the condition of the handle position of the adjacent poles. Functional signal contact Type S1 assumes the same contact position Type S2 assumes the opposite position The signal contact operates due to a thermal magnetic tripping and must be reset by hand. PH Functional auxiliary contact When voltage is applied across the terminals, remote tripping takes place by a self interrupting magnetic system. Trip delay time 8 - 16 ms. Type A1 A2 A3 A4 A5 Maximum Pole combination The maximum allowed number of poles/modules is 6, but in any combination, only 1 or 2 add-on modules are permitted 1 or 2 add-on modules only 1 add-on module 1 or 2 add-on modules Voltage range AC/DC 5 - 12 V 10 - 24 V 20 - 48 V 40 - 110 V 90 - 240 V Impedance at 50 Hz 1.1 Ω 4.7 Ω 16 Ω 63 Ω 395 Ω Function of relay trip module + 1 or 2 or 3 pole + 4 pole + 4 pole The time-current-curves are not relevant for the add-on modules. 4 Circuit Breakers + switched neutral + switched neutral AS168X Add-on modules Thermal-magnetic (TM and AS-line) https://www.schurter.com /PG20 Config. Code AS168X-ACB|H1|S2|A3|LOA| AS168X-ACB| H1 |S2|A3|LOA| = Auxiliary contact Auxiliary contact Relay trip module Configuration key T  The characters are placeholders for the correspondingly keys of selections from the key tables. Relay trip module AC/DC 5 -12 V A1 A2 A3 H1 Auxiliary contact opposited H2 Relay trip module AC/DC 20 - 48 V Signal contact OU Auxiliary contact synchronized Relay trip module AC/DC 10 -24 V AS168X-ACB|H1| S2 |A3|LOA| = Signal contact Configuration key Signal contact synchronized Relay trip module AC/DC 40 -110 V A4 Relay trip module AC/DC 90 -240 V A5 AS168X-ACB|H1|S2|A3| LOA | = Relay trip module S1 Signal contact opposited Configuration key Accessories S2 Configuration key Lockout attachment AS168X-ACB|H1|S2| A3 |LOA| = Relay trip module Auxiliary contact Signal contact Auxiliary contact synchronized   Auxiliary contact opposited           E- Variants Relay trip module Accessories Config. Code Order Number     AS168X-ACBH1 4420.0163     AS168X-ACBH2 4420.0176 Relay trip module AC/DC 20 - 48 V   AS168X-ACBA3 4420.0189 Relay trip module AC/DC 10 -24 V   AS168X-ACBA2 4420.0340 Signal contact synchronized     AS168X-ACBS1 4420.0414 Signal contact opposited     AS168X-ACBS2 4420.0415     Lockout attachment AS168X-ACBLOA 4420.0799 AS       LOA Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER 1 Pcs  The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 19.02.2018 PH Packaging Unit   Circuit Breakers 5
4420.0176 价格&库存

很抱歉,暂时无法提供与“4420.0176”相匹配的价格&库存,您可以联系我们找货

免费人工找货