AS168XAC2
Thermal-magnetic (TM and AS-line)
https://www.schurter.com /PG20
OU
T
Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 2 poles
See below:
Approvals and Compliances
Description
- Thermal-magnetic circuit breaker
- High short circuit performance
- Availability of AC and DC in the same frame size
- DIN-Rail Mounting
Applications
- Industrial appliances
References
Last order possibility: 31.08.2018
Last delivery date: 30.09.2018
Weblinks
pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Detailed request for product, Product News
General data
Rated Voltage AC
␣
Rated Voltage DC
Rated current
Conditional short circuit capacity IEC 60934
Conditional short circuit capacity UL 1077
E-
Technical Data
Tripping Type
IEC : 420 V Y / 240 V; 50/60 Hz
UL/CSA : 480 V Y / 277 V; 50/60 Hz
65 V
0.5 - 52 A , see approbations
Icn: AC 420 V / DC 65 V: 5 kA (no fuse)
Add-on modules
Add-on modules
Positively trip free
Manual ON/OFF
1.5 - 25 mm² / 16 - 4 AWG
AC 277 V
AC/DC 65 A
The switched neutral closes with manual closure of the poles and opens
automatically with thermal magnetic
tripping of the poles.
Technical data for the additional module
see separate data sheet
PH
AS
Inc: AC 480 V: 10 kA (with fuse class
H/J, 4x rated current (min. 15 A))
Icn: AC 480 V: 5 kA (no fuse)
Icn: DC 65 V: 2 kA (no fuse)
Conditional short circuit capa- Icn: AC 480 V: 5 kA (no fuse)
city UL 508
Degree of Protection
from front side IP 40 acc. to IEC 60529
Lifetime
1 x Ir 6000 switching cycles
Dielectric Strength
50 Hz: > 2 kV
Impulse 1.2/50 μs
Vibration Resistance
± 0.75 mm @ 5 - 60 Hz
acc. to IEC 60068-2-6, test Fc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
Insulation Resistance
250/440 VAC > 5 MΩ
Shock Resistance
30 G / 18 ms
acc. to IEC 60068-2-27, test Ea
Ambient temperature
-10 °C to 55 °C
Weight
100 - 130 g
Actuation Type
Permissible wire cross section
Switched neutral
Rated Voltage
Rated current
Function
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
Circuit Breakers
1
AS168XAC2
Thermal-magnetic (TM and AS-line)
https://www.schurter.com /PG20
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: AS168X
Certification Body
Description
VDE Approvals
VDE
VDE Certificate Number: 40005743
UL Approvals
UL
UL File Number: E216629 / E71572
UL Approvals
UL
UL File Number: E216629 / E71572
Product standards
Product standards that are referenced
Organization
Design
Standard
Designed according to
IEC 60934
Designed according to
UL508, UL1077
Designed according to
UL 508
Designed according to
CSA C22.2
Application standards
Application standards where the product can be used
Design
Standard
Designed for applications acc.
Standard for Supplementary Protectors for Use in Electrical Equipment
Standard for Industrial Control Equipment
Supplementary Protectors
Description
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Initiator
Description
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
SCHURTER AG
EU Directive RoHS 2011/65/EU
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
The product complies with following Guide Lines
Details
CE declaration of conformity
PH
AS
RoHS
2
Circuit-breakers for equipment (CBE)
IEC/UL 60950
Compliances
Identification
Description
E-
Organization
T
Certificates
OU
Approval Logo
Circuit Breakers
AS168XAC2
Thermal-magnetic (TM and AS-line)
https://www.schurter.com /PG20
Dimension [mm]
AS168X 2 pole
35
A)
1.9
90
B)
T
5.1
26.6
44.4
OU
68.4
61.6
45
35
A)
B)
35 mm DIN rail EN 50022
Max. torque
AS168X 2 pole and switched neutral pole
E-
Wire crosssection
1.5 ... 10 mm2
16 ... 25 mm2
AWG #16 ... 8
AWG #6 ... 4
Max. torque
2.5 Nm
3.1 Nm
20 ... 22 lb –in
26 ... 28 lb –in
68.4
A)
5.1
35
26.6
44.4
61.6
AS
45
52.5
PH
1.9
90
B)
A)
B)
35 mm DIN rail EN 50022
Max. torque
Wire crosssection
1.5 ... 10 mm2
16 ... 25 mm2
AWG #16 ... 8
AWG #6 ... 4
Circuit Breakers
Max. torque
2.5 Nm
3.1 Nm
20 ... 22 lb –in
26 ... 28 lb –in
3
AS168XAC2
Thermal-magnetic (TM and AS-line)
https://www.schurter.com /PG20
Diagrams
AS168X-CB1...N
OU
T
AS168X-CB1...
AS168X-CB1... / AS168X-ACBS2
AS
AS168X-CB1... / AS168X-ACBS1
AS168X-CB1... / AS168X-ACBH2
E-
AS168X-CB1... / AS168X-ACBH1
PH
AS168X-CB1... / AS168X-ACBA
4
Circuit Breakers
AS168XAC2
Thermal-magnetic (TM and AS-line)
https://www.schurter.com /PG20
Standard
Rated current
Rated voltage AC
Conditional short circuit
capacity Icn
Rated voltage DC
Conditional short circuit
capacity Icn
UL 508
CSA C22.2 no. 14
0.5 - 52 A
480Y/277 V
5 kA
-
-
UL 1077
-
-
-
-
-
0.5 - 50 A
480 V
5 kA
0.5 - 30 A
240/420 V
4.5 kA
GB 17701
-
-
-
Effect of ambient temperature
65 V
2 kA
65 V
4.5 kA
-
-
T
CSA C22.2 no. 235
EN 60934
OU
Symbol
AC-breaker are calibrated for an ambient temperature of +40°C, DC-breakers for +23°C. To determine the rated current for a lower or
higher ambient temperature, use a correction factor from the table below:
Ambient temperature [°C]
Correction factor AC version
Correction factor DC version
-20
0.78
0.80
-5
0.82
0
0.83
+10
0.87
+23
0.91
+30
0.95
+40
1.00
+50
1.05
+60
1.11
0.87
0.90
0.95
1.00
1.05
1.10
1.20
E-
1.30
PH
AS
Example DC version: Rated current = 10 A; Environmental temperature = 50 °C; --> Correction factor = 1.2; Resulting current = 12 A
Circuit Breakers
5
AS168XAC2
Thermal-magnetic (TM and AS-line)
https://www.schurter.com /PG20
Ampere-Horsepower
Horsepower
(FLA & LRC Ratings Apply where no HP Rating is given)
110120
AS168X-CB
FLA
Rating
0.5A
1A
1.5A
2A
3A
4A
5A
6A
7A
8A
9A
10A
12A
13A
15A
16A
18A
20A
23A
25A
27A
30A
Starting/
LRC Rating
3°
6°
9°
12A
18A
24A
30A
36A
42A
48A
54A
60A
72A
78A
90A
96A
108A
120A
138A
150A
162A
180A
Motor Nameplate
FLA
Rating
0.5A
1A
1.5A
2A
3A
4A
5A
6A
7A
8A
9A
10A
12A
13A
15A
16A
18A
20A
23A
25A
27A
30A
1/10
1/8
1/6
1/4
1/4
1/3
1/3
1/2
1/2
1/2
3/4
1
1
1 1/2
1 1/2
2
2
2
1/6
1/4
1/3
1/2
1/2
3/4
3/4
1
1 1/2
1 1/2
2
2
2
3
3
3
3
3
1/10
1/8
1/4
1/3
1/2
1/2
3/4
1
1
1 1/2
2
2
2
2
3
3
3
3
3
5
1/6
1/3
1/3
1/2
1/2
3/4
1
1
1 1/2
1 1/2
2
2
2
3
3
3
3
3
1/10
1/6
1/3
1/3
1/2
3/4
1
1
1 1/2
2
2
2
3
3
3
3
3
5
5
5
1/10
1/6
1/4
1/3
1/2
3/4
1
1 1/2
2
2
2
3
3
3
3
5
5
5
5
7 1/2
7 1/2
Starting/
LRC Rating
PH
10A
12.5A
20A
25A
32A
32A
32A
46A
46A
46A
63.5A
63.5A
81A
81A
81A
81A
116A
116A
145A
145A
1/2
1/2
3/4
3/4
1
1
1 1/2
1 1/2
2
2
2
3
3
3
3
3
1/2
3/4
1
1
1/2
2
2
2
3
3
3
3
5
5
5
5
7 1/2
7 1/2
1/2
3/4
1
1
1/2
2
2
2
3
3
3
3
5
5
5
7 1/2
7 1/2
7 1/2
Note #1: For AC motor circuit nameplate FLA loads, AC general-use loades, AC resistance loads
6
1/10
1/6
1/4
1/3
1/2
3/4
1
1
1
1 1/2
2
2
3
3
3
3
3
5
5
5
2 pole
Horsepower
(FLA & LRC Ratings Apply where no HP Rating is given)
Nominal Circuit Voltage, VAC
110-120
200
208
220-240
380-415
AS
Rated Current
(See Note #1)
0.5A
1A
1.5A
2A
3A
4A
5A
6A
7A
8A
9A
10A
12A
13A
15A
16A
18A
20A
23A
25A
27A
30A
Circuit Breakers
440480
380415
1 pole
E-
Rated Current
(See Note #1)
0.5A
1A
1.5A
2A
3A
4A
5A
6A
7A
8A
9A
10A
12A
13A
15A
16A
18A
20A
23A
25A
27A
30A
200
Nominal Circuit Voltage, VAC
220208
265
277
240
T
Motor Nameplate
OU
AS168X-CB
1/2
1
1 1/2
2
2
2
3
3
3
3
5
5
5
5
7 1/2
7 1/2
10
10
440-480
3 pole
1/2
3/4
1
1/2
2
2
2
3
3
3
3
5
5
5
7 1/2
7 1/2
7 1/2
10
1/2
3/4
1
1 1/2
2
2
3
3
3
5
5
5
7 1/2
7 1/2
10
10
10
10
15
15
1/2
3/4
1 1/ 2
2
3
3
3
5
5
5
7 1/ 2
7 1/ 2
10
10
10
10
15
15
20
20
AS168XAC2
Thermal-magnetic (TM and AS-line)
https://www.schurter.com /PG20
Time-Current-Curves
1hr
1000s
1000s
100s
100s
10s
10s
OU
1hr
1s
0,1s
10ms
T
Version G / Magnetic 6-10 xln
Time in Seconds
Time in Seconds
Version F / Magnetic 3-5 xln
1s
0,1s
10ms
1ms
1ms
0,1ms
0,1ms
1
10
100
1000 x In
Multiple of Rated Current In
1
10
100
1000 x In
Multiple of Rated Current In
Reference Temperature +23°
E-
Reference Temperature +23°
Version H / Magnetic 12-20 xln
1hr
1000s
AS
100s
Time in Seconds
10s
1s
0,1s
10ms
PH
1ms
0,1ms
1
10
100
1000 x In
Multiple of Rated Current In
Reference Temperature +23°
Config. Code
AS168X-CB|1|DG|200|N|
The characters are placeholders for the correspondingly keys of selections from the key tables.
AS168X-CB| 1 |DG|200|N| = Number of Poles
Number of Poles
Configuration
key
2-pole
2
Circuit Breakers
7
AS168XAC2
Thermal-magnetic (TM and AS-line)
https://www.schurter.com /PG20
AS168X-CB|1| DG |200|N| = Tripping characteristics
Configuration
key
1.0-1.25xIn / 3-5xIn / 0.5-52 A
F
1.0-1.25xIn / 6-10xIn / 0.5-52 A
G
1.0-1.25xIn / 12-20xIn / 0.5-52 A
H
12.0 A
120
15.0 A
150
16.0 A
160
18.0 A
180
20.0 A
200
23.0 A
AS168X-CB|1|DG| 200 |N| = Rated current
230
25.0 A
Configuration
key
250
27.0 A
270
30.0 A
OU
Rated current
Configuration
key
T
Tripping characteristics
Rated current
0.05 A
005
1.0 A
010
1.5 A
015
2.0 A
020
3.0 A
030
4.0 A
040
050
6.0 A
060
7.0 A
070
8.0 A
080
9.0 A
090
10.0 A
100
Other rated currents on request
Variants
Rated current
1.0-1.25xIn / 3-5xIn / 0.5-52 A
15.0 A
350
40.0 A
400
45.0 A
450
50.0 A
500
52.0 A
520
Other rated currents on request
AS168X-CB|1|DG|200| N | = Switched neutral
Switched neutral
Switched neutral
Config. Code
Order Number
AS168X-CB2F150
4420.0251
1.0-1.25xIn / 3-5xIn / 0.5-52 A
20.0 A
AS168X-CB2F200
4420.0371
1.0-1.25xIn / 6-10xIn / 0.5-52 A
1.0 A
AS168X-CB2G010
4420.0370
1.0-1.25xIn / 6-10xIn / 0.5-52 A
2.0 A
AS168X-CB2G020
4420.0235
1.0-1.25xIn / 6-10xIn / 0.5-52 A
4.0 A
AS168X-CB2G040
4420.0236
1.0-1.25xIn / 6-10xIn / 0.5-52 A
5.0 A
AS168X-CB2G050
4420.0237
1.0-1.25xIn / 6-10xIn / 0.5-52 A
6.0 A
AS168X-CB2G060
4420.0281
1.0-1.25xIn / 6-10xIn / 0.5-52 A
7.0 A
AS168X-CB2G070
4420.0396
1.0-1.25xIn / 6-10xIn / 0.5-52 A
10.0 A
AS168X-CB2G100
4420.0238
1.0-1.25xIn / 6-10xIn / 0.5-52 A
12.0 A
AS168X-CB2G120
4420.0227
1.0-1.25xIn / 6-10xIn / 0.5-52 A
15.0 A
AS168X-CB2G150
4420.0205
PH
Configuration
key
Switched neutral pole
AS
Tripping characteristics
320
35.0 A
E-
5.0 A
300
32.0 A
N
█
█
█
1.0-1.25xIn / 6-10xIn / 0.5-52 A
16.0 A
AS168X-CB2G160
4420.0225
1.0-1.25xIn / 6-10xIn / 0.5-52 A
18.0 A
AS168X-CB2G180
4420.0819
1.0-1.25xIn / 6-10xIn / 0.5-52 A
20.0 A
AS168X-CB2G200
4420.0239
1.0-1.25xIn / 6-10xIn / 0.5-52 A
25.0 A
AS168X-CB2G250
4420.0240
1.0-1.25xIn / 6-10xIn / 0.5-52 A
30.0 A
AS168X-CB2G300
4420.0221
█
1.0-1.25xIn / 6-10xIn / 0.5-52 A
40.0 A
AS168X-CB2G400
4420.0200
█
1.0-1.25xIn / 6-10xIn / 0.5-52 A
50.0 A
AS168X-CB2G500
4420.0380
█
1.0-1.25xIn / 12-20xIn / 0.5-52 A
1.0 A
AS168X-CB2H010
4420.0325
1.0-1.25xIn / 12-20xIn / 0.5-52 A
2.0 A
AS168X-CB2H020
4420.0335
1.0-1.25xIn / 12-20xIn / 0.5-52 A
3.0 A
AS168X-CB2H030
4420.0273
1.0-1.25xIn / 12-20xIn / 0.5-52 A
4.0 A
AS168X-CB2H040
4420.0605
1.0-1.25xIn / 12-20xIn / 0.5-52 A
6.0 A
AS168X-CB2H060
4420.0207
8
Circuit Breakers
█
AS168XAC2
Thermal-magnetic (TM and AS-line)
https://www.schurter.com /PG20
Tripping characteristics
Rated current
Switched neutral
Config. Code
Order Number
1.0-1.25xIn / 12-20xIn / 0.5-52 A
7.0 A
AS168X-CB2H070
4420.0317
8.0 A
AS168X-CB2H080
4420.0272
10.0 A
AS168X-CB2H100
4420.0174
1.0-1.25xIn / 12-20xIn / 0.5-52 A
12.0 A
AS168X-CB2H120
4420.0416
1.0-1.25xIn / 12-20xIn / 0.5-52 A
15.0 A
AS168X-CB2H150
4420.0296
1.0-1.25xIn / 12-20xIn / 0.5-52 A
16.0 A
AS168X-CB2H160
4420.0670
1.0-1.25xIn / 12-20xIn / 0.5-52 A
20.0 A
1.0-1.25xIn / 12-20xIn / 0.5-52 A
30.0 A
1.0-1.25xIn / 12-20xIn / 0.5-52 A
50.0 A
OU
█ Most Popular.
T
1.0-1.25xIn / 12-20xIn / 0.5-52 A
1.0-1.25xIn / 12-20xIn / 0.5-52 A
█
AS168X-CB2H200
4420.0220
█
AS168X-CB2H300
4420.0223
█
AS168X-CB2H500
4420.0560
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
1 Pcs
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
19.02.2018
PH
AS
E-
Packaging Unit
Circuit Breakers
9