TA45-2R
Thermal (T- and TA-Line)
www.schurter.com /PG17_20
Circuit Breaker for Equipment thermal, 2 pole, Rocker actuation
Description
- Thermal circuit breaker
- 1 or 2 pole thermal overload protection
- Positively trip-free release
- High configurability
- Rocker non-illuminated or illuminated
- Snap-in version
- Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x
6 mm (lineside P1, P2)
Applications
- Power tools
- Industrial appliances
- Power supplies
Weblinks
pdf datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, DistributorStock-Check, Detailed request for product, Product News
Approvals
- Approval Reference Type: TA45
- IEC Standard: IEC 60934
- UL Standard: UL 1077
- CSA Standard: CSA C22.2 No. 235
- GB Standard: GB 17701
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current range AC
Conditional short circuit capacity
Degree of Protection
Dielectric Strength
Insulation resistance
Endurance typical
␣
240 V
60 V
0.05 - 20 A
IEC: Inc, PC1, AC 240 V: 1 kA
from front side IP 40 acc. to IEC 60529
4 kVAC
500 VDC > 100 MΩ
mechanical: 50'000 switching cycles
AC: 1 x Ir:
50'000 switching cycles
DC: 1 x Ir:
50'000 switching cycles
␣
Dimension
Quick connect terminal
Overload
AC: min. 40 trips
@ 6 x Ir
DC: min. 40 trips
@ 4 x Ir
-10 °C to 55 °C
± 0.75 mm @ 5 - 60 Hz
acc. to IEC 60068-2-6, test Fc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
30 G / 18 ms
acc. to IEC 60068-2-27, test Ea
Thermal
Rocker
30 - 35 g
␣
Ambient temperature
Vibration Resistance
Shock Resistance
Tripping Type
Actuation Type
Weight
Screw clamp terminal
25
16
34
10.8
23.7
44.1
P1 a
P1 a
3
3
5
5
10.6
5.3
26.7
12.5
3.5
48
26.7
8.4
B)
10.8
A)
A) Quick connect terminal, IEC 61210, A6.3-0.8 mm
10.8
21.5
B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm
Circuit Breakers
1
TA45-2R
Thermal (T- and TA-Line)
www.schurter.com /PG17_20
Accessories / factory mounted
AZM01 / Collar with cover, IP54
AZM02 / Raised collar with cover, narrow, IP54
AZM03 / Raised collar, IP40
33.6
27.5
19.2
33.6
27.5
19.2
56.5
50.5
43.7
43.7
15.3
17.6
12.5
17.6
8.1
56.6
50.5
48
AZM10 / Collar with cover, narrow, IP54
27
19.2
17.3
8.8
17.3
50
48
43.8
43.8
14
50
37.2
AZM11 / Partially raised collar with cover, narrow, IP54
AZM12 / Partially raised collar without cover, narrow, IP40
Circuit Breakers
14
17.3
33.2
10.6
2
27
19.2
50
33.2
27
14
50
AZM14 / Raised collar with cover narrow, IP54
10.6
AZM13 / Raised collar narrow, IP40
TA45-2R
Thermal (T- and TA-Line)
www.schurter.com /PG17_20
Cut-out and pin-out
Cut-out snap-in type
a (1.0 – 5.0)
21.7 – 0.0
+0.2
Pin-out
b
1)
a
b
1.0
1.5
2.0
2.5
3.0
4.0
5.0
44,5...45,0
44,5...45,0
44,7...45,2
44,7...45,2
44,8...45,3
44,9...45,4
45,0...45,5
U-Relais
P2
P1
b
a
c
4
6
3
5
2)
1) Assemble
2) edge must be sharp
Circuit Breakers
3
TA45-2R
Thermal (T- and TA-Line)
www.schurter.com /PG17_20
Diagrams
Without thermal overload protection
1 pole thermal overload protection
P2
P1
P2
6
5
6
1 pole thermal overload protection, Shunt terminal
P2
6
5
2 pole thermal overload protection, Shunt terminal
6
P2
P1
4
3
5
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient temperature [°C]
Correction factor
-10
0.89
-5
0.91
0
0.92
+23
1.00
+30
1.03
+40
1.08
+55
1.16
Example: Rated current = 5 A; Environmental temperature = 40 °C; --> Correction factor =
1.08; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A
4
Circuit Breakers
3
2 pole thermal overload protection
P1
3
P1
P2
P1
4
3
TA45-2R
Thermal (T- and TA-Line)
www.schurter.com /PG17_20
Time-Current-Curves
[ min ] [ sec ]
10'000
Type
TA45
Rated current
In 18 A
Rated current
60
20
3 A > In