TA35 Rocker 3Pole
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_20
Circuit Breaker for Equipment thermal, Rocker actuation, 3 poles
See below:
Approvals and Compliances
Description
- Thermal circuit breaker
- 3-pole
- Snap-in version
- Positively trip-free release
- Method of operation acc. to IEC: S-type
- Different rocker colours
- Wide current range
Unique Selling Proposition
Applications
- Power tools
- Medical and laboratory equipment
- Industrial appliances
- Equipment for construction
- Cleaning equipment
- Commercial and household kitchen appliances
- Industrial Power
- Industrial lighting arrays
- 1-, 2- or 3-pole versions
- Finely graded rated currents
- High configurability (rocker colours, lettering, illumination)
- IP65 with optional cover
Other versions on request
Technical Data
Rated Voltage AC
Rated current range AC
Conditional short circuit capacity Inc
Degree of Protection
Dielectric Strength
Insulation Resistance
Lifetime
␣
␣
415 Y VAC / 240 VAC
0.05 - 12 A
IEC 60934: 0.05...12 A: 2 kA @ 415
VAC
front side IP40 acc. to IEC 60529
50 Hz: > 2.5 kV
Impulse 1.2/50 μs: > 4 kV
500 VDC > 100 MΩ
mechanical: 50'000 switching cycles
AC: 1 x Ir, cos φ 0.6:
50'000 switching cycles
DC: 1 x Ir, L/R = 2 - 3 ms:
50'000 switching cycles
- White front cover
Weblinks
pdf data sheet, html datasheet, General Product Information, DistributorStock-Check, Detailed request for product, Product News
Overload
␣
Allowable Operation Temp.
Storage Temperature
Vibration Resistance
Shock Resistance
Tripping Type
Actuation Type
Weight
IEC: min. 40 trips
@ 6 x Ir, cos φ 0.6
UL / CSA: min. 50 trips
@ 1.5 x Ir, cos φ 0.75
-30 °C to 60 °C
-40 °C to 60 °C
± 0.75 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Tc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Tc
30 G / 18 ms
acc. to IEC 60068-2-27, test Ea
Thermal
Rocker
43.0 - 45.0 g
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.
Circuit Breakers
1
TA35 Rocker 3Pole
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_20
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: TA35
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
VDE Certificate Number: 40019754
UL Approvals
UL
UR File Number: E71572
CCC Approvals
CCC
CCC Certificate Number: 2020970307001846
Design
Standard
Description
Designed according to
IEC 60934
Circuit-breakers for equipment (CBE)
Designed according to
UL 1077
Standard for Supplementary Protectors for Use in Electrical Equipment
Designed according to
CSA C22.2 No. 235
Supplementary Protectors
Designed according to
GB 17701
Circuit-breaker for equipment
Design
Standard
Description
Suitable for applications acc.
IEC/UL 62368-1
Audio/video, information and communication technology equipment - Part
1: Safety requirements
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
UKCA declaration of conformity
SCHURTER AG
The UKCA marking declares that the product complies with the applicable
requirements laid down in the British Amendment of Regulation (EC)
765/2008.
RoHS
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Product standards
Product standards that are referenced
Organization
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
Dimension [mm]
40.5
34
31.9
37.5
+0.2
0
7.2
1.7
36
10.6
21.3
11
2.3
34.5
33.8
6.3 x 0.8 mm
2
11 6.1
Circuit Breakers
37.4
+0.2
0
34
44.1
10.5
LINE
L
33.5
+0.3
Panel 1.0 − 4.0 mm
TA35 Rocker 3Pole
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_20
Diagrams
3-pole, 3 bimetal, illuminated
3-pole, 3 bimetal, non illuminated
1)
P1
1)
P2
P3
P1
5
6
4
4
2)
P2
P3
5
6
2)
1) Line, 2) Load
Codepos AAA = CD1
1) Line, 2) Load
Codepos AAA = CKD, CLD
The keys / codepos are listed in the key table of the basic function for selection.
Approvals
Approval
Rated current
Rated Voltage AC
Rated Voltage DC
UL 1077
0.05...12 A
415 Y / 240 V
-
CSA C22.2
235
0.05...12 A
415 Y / 240 V
-
IEC 60934
0.05...12 A
415 Y / 240 V
-
GB 17701
0.05...12 A
415 Y / 240 V
-
Typical internal resistance per pole
Rated Current [A]
Internal Resistance [Ω]
0.05
200.000
0.1
70.000
0.5
2.750
1.0
0.720
1.5
0.340
2.0
0.187
2.5
0.115
2.8
0.089
3.0
0.059
4.0
0.059
5.0
0.044
6.0
0.028
7.0
0.0142
8.0
0.0142
10.0
0.0109
12.0
0.0086
13.0 *
0.0072
14.0 *
0.0072
15.0 *
0.0056
16.0 *
0.0056
18.0 *
0.0052
20.0 *
0.0052
* 3-Pole max. 12 A
TA35 Rocker 3-poles max. 12 A
Circuit Breakers
3
TA35 Rocker 3Pole
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_20
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient Temperature [°C]
Correction factor
-30
0.76
-20
0.81
0
0.90
+23
1.00
+40
1.06
+50
1.10
+60
1.14
Example: Rated current = 5 A, Environmental temperature = 50 °C, --> Correction factor =
1.10, Resulting current = 5.2 A --> Round to next higher rated current: 6 A
Time-Current-Curves
Tripping Characteristics In < 3 A
Tripping Characteristics In 3 -20 A
[min] [sec ]
10'000
[min] [sec ]
10'000
TA35
60
30
20
10
TA35
3-20A (TC-1, TC-2)
(3 pole
max. 12A)
60
3 pole
Circuit Breakers
2
3
4
5
8
10
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_20
TA35 Rocker 3Pole
Circuit Breakers
5
TA35 Rocker 3Pole
6
Circuit Breakers
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_20
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_20
TA35 Rocker 3Pole
Circuit Breakers
7
TA35 Rocker 3Pole
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_20
All Variants
Basic function
Rocker colour
Legend
Rated current
Accessories
Config. Code
Order Number
3-pole, 3 bimetal, without illumination
Black
white printed
2.5 A
Without cover
TA35-CKDBHJ25C0-000
4435.0229
3-pole, 3 bimetal, without illumination
White
embossed
3.0 A
Without cover
TA35-CKDWF030C0-000
4435.0025
3-pole, 3 bimetal, without illumination
Black
white printed
4.0 A
Without cover
TA35-CKDBH040C0-000
4435.0232
3-pole, 3 bimetal, without illumination
White
embossed
5.0 A
Without cover
TA35-CKDWF050C0-000
4435.0044
3-pole, 3 bimetal, without illumination
Black
white printed
5.0 A
Without cover
TA35-CKDBH050C0-000
4435.0048
3-pole, 3 bimetal, without illumination
Black
white printed
6.0 A
Without cover
TA35-CKDBH060C0-000
4435.0233
3-pole, 3 bimetal, without illumination
White
embossed
10.0 A
Without cover
TA35-CKDWF100C0-000
4435.0050
3-pole, 3 bimetal, without illumination
Black
white printed
10.0 A
Without cover
TA35-CKDBH100C0-000
4435.0235
3-pole, 3 bimetal, without illumination
White
embossed
12.0 A
Without cover
TA35-CKDWF120C0-000
4435.0017
3-pole, 3 bimetal, illuminated 415 V
Red transparent
white printed
12.0 A
Without cover
TA35-CD13L120C0-000
4435.0414
█
█ Most Popular.
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Packaging Unit
10 Pcs
Accessories
Description
TA35 Accessories
Screw-on collar with cover, IP65
09.06.2022
8
Circuit Breakers
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.