5145
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
IEC Appliance Inlet C14 or C18 with Filter, Circuit Breaker TA45
Protection class II without shield
C14
Protection class I with shield
C18
See below:
Approvals and Compliances
70° C
70° C
Description
- Panel mount :
Screw-on mounting front side
- 3 Functions :
Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole
, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
Unique Selling Proposition
- Compact power entry module with circuit breaker
- High configurability
- Easy assembly with prewired modules
- Protection class I or II
Characteristics
- All single elements are already wired
- Unwired versions available on request
- Circuit Breaker non-illuminated or illuminated
- For applications according IEC/UL 62368-1 we recommend variants
with bleed resistor
Suitable for use in medical equipment according to IEC/UL 60601-1 (1
MOOP, 1 MOPP)
References
Alternative: version without line filter 6145
We recommend for new applications DF12
Weblinks
pdf data sheet, html datasheet, General Product Information, Approvals,
Distributor-Stock-Check, Accessories, Detailed request for product,
Microsite
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temperature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Material
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21 acc. to IEC 60068-1
front side IP40 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance inlet/-outlet
Circuit Breakers
Line Filter
MTBF
C14 or C18 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I or II
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 100'000 h acc. to MIL-HB-217 F
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.
EMC Products
1
5145
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: 5145
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40035745
UL Approvals
UL
UR File Number: E72928
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
IEC 60939
Passive filters for suppressing electromagnetic interference
Designed according to
IEC 61058-1
Switches for appliances. Part 1. General requirements
Designed according to
UL 498
Standard for Attachment Plugs and Receptacles
Designed according to
UL 1283
Electromagnetic interference filters
Designed according to
CSA C22.2 no. 42
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Designed according to
CSA C22.2 no. 8
Electromagnetic interference (EMI) filters
Design
Standard
Description
Suitable for applications acc.
IEC/UL 62368-1
Audio/video, information and communication technology equipment - Part
1: Safety requirements
Suitable for applications acc.
IEC 60601-1
Medical electrical equipment - Part 1: General requirements for basic
safety and essential performance
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
UKCA declaration of conformity
SCHURTER AG
The UKCA marking declares that the product complies with the applicable
requirements laid down in the British Amendment of Regulation (EC)
765/2008.
RoHS
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Medical Equipment
SCHURTER AG
Suitable for use in medical equipment according to IEC/UL 60601-1 (1
MOOP, 1 MOPP)
Product standards
Product standards that are referenced
Organization
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
2
EMC Products
5145
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Dimension [mm]
Detail A
2
0
36
29 +0.2
1
43
6.3x0.8mm
ø6
3.25
A
0
80 ±0.1
72
+0.1
0
80
91.5
R 3-0.5
6.3x0.8mm
50.7
M3/ø 3.6
13.5
67.5*
* --- Version TA45 with undervoltage release
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
1
Standard version
2 x 11
47
2.2
-
2
Standard version
2x4
47
2.2
-
3
Standard version
2 x 2.5
47
2.2
-
4
Standard version
2 x 1.6
47
2.2
-
6
Standard version
2 x 0.7
47
2.2
-
8
Standard version
2 x 0.6
47
2.2
-
10
Standard version
2 x 0.4
47
2.2
-
15
Standard version
2 x 0.1
47
2.2
-
1
Medical Version (M5)
2 x 11
47
-
1
2
Medical Version (M5)
2x4
47
-
1
6
Medical Version (M5)
2 x 0.7
47
-
1
8
Medical Version (M5)
2 x 0.6
47
-
1
10
Medical Version (M5)
2 x 0.4
47
-
1
15
Medical Version (M5)
2 x 0.1
47
-
1
EMC Products
3
5145
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Diagrams
Medical Version (M5)
Medical filter (M5) protection class II
P1
PE
Cx
TA 45
L1
1)
PE’
R
L2
N’
N
L’
L
2)
L1
1)
Cx
P2
R
L2
N’
N
1) Line
2) Load
P1
TA 45
L’
L
2)
P2
1) Line
2) Load
Standard version
L’
L
P1
PE
Cy
Cx
N
L2
Cy
TA 45
L1
1)
PE’
N’
2)
P2
1) Line
2) Load
Attenuation Loss
- - - - 50Ω differential mode _____ 50Ω common mode
Standard version
15A
1A
2A
4A
3A
6A
10 A
8A
4
EMC Products
5145
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Medical version (M5)
1A
2A
6A
3A
4A
8A
15A
10 A
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient Temperature [°C]
Correction factor
-10
0.89
-5
0.91
0
0.92
+23
1.00
+30
1.03
+40
1.08
+55
1.16
Example: With a nominal current of 5A and an ambient temperature of 40°C, a correction
factor of 1.08 results. This results in a nominal current of 5.5 A, which is rounded up to the
next higher nominal current 6 A.
EMC Products
5
5145
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Time-Current-Curves
Tripping Characteristics In ≥ 3 ... ≤ 15 A
Tripping Characteristics In < 3 A
[ min ] [ sec ]
10’000
[ min ] [ sec ]
10’000
Type
TA45
Type
Rated current
In < 3 A
Rated current
60
2000
30
20
1000
10
Ambient temp.
1-pole pr otected
60
2- pole protected
30
2’000
+23 °C
Ambient temp.
500
5
5
200
200
100
1
100
1
50
20
20
10
10
5
5
2
2
1
1
0,5
0,5
Tripping time
Tripping time
50
0,3
0,2
0,1
1,05 1,32
2
Multiple of rated curr ent
6
2- pole protected
1’000
10
500
I n > 3... < 15 A
1-pole p rotected
20
+23 °C
TA45
3
4
5
8
10
[ x In ]
EMC Products
0,3
0,2
0,1
1,05 1,32
2
Multiple of rated cur rent
3
4
5
8
[ x In ]
10
5145
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Order number key
Configuration code (Order example)
Type
Configuration code TA45
514 5 - ABTWF150C0 - 0 0 0 - 111 - 10 - 0 0
Optional Variants
00 standard
21 V-Lock notch
Terminal PE
0 without (PCII)
1 QC 6.3x0.8
Terminal L and N
1 QC 6.3x0.8, without connection to TA45
3 Connection to TA45 non insulated
Metal Shield Filter
0 with metal shield (PCI)
1 without metal shield (PCI and PCII)
Type of mains fi lter / capacitor / bleed resistor
1 standard
X2,Y2
without
3 medical M5
X2
with
2)
Rated current
1 1A
2 2A
3 3A
4 4A
5 6A
6 8A
7 10A
8 15A
1) Not in conjunction with PC II
2) The rated current of the mains filter must not be less than
the tripping current of the circuit breaker for equipment.
Only the rated filter current is shown in the item description on the packaging.
EMC Products
1)
7
5145
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Configuration code TA45
Type
• Circuit Breaker of Equipment
• 2-pole, rocker actuated
• Quick connect terminal
Other types on request
Configuration code TA45
5 145 -A B T WF 15 0C 0 - 0 0 0 - 111 - 10 - 0 0
Without release: code C0
Undervoltage release
P2
P2
P1
Remote trip release
P1
b
U<
U<
P2
ba
P2
P1
c P1
U<
Rated
voltage Un
U
E
Z
A
Code
•
•
•
•
2
240 V AC
•
•
•
•
3
230 V AC
•
•
•
•
4
120 V AC
Rated current circuit breaker of equipment
In
Code
In
Code
In
Code
In
Code
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1,0
1,1
1,2
J01
J02
J03
J04
J05
J06
J07
J08
J09
J10
J11
J12
1,3
1,4
1,5
1,6
1,7
1,8
1,9
2,0
2,1
2,2
2,3
2,5
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J25
2,8
3,0
3,5
4,0
4,5
5,0
6,0
6,5
7,0
7,5
8,0
9,0
J28
030
035
040
045
050
060
065
070
075
080
090
10,0
11,0
12,0
13,0
14,0
15,0
20,0
100
110
120
130
140
150
200
Rocker legend
Surface
printed
Colour of print
printed
printed
white
M
printed
black
P
printed
I
O
white
R
printed
I
O
black
l
ON ON
l
K
L
O OFF OFF O
H
Illustration
O
embossed
l
F
Position of the rocker legend e.g F
white
black
Colours
Switch front
W
B
6
black
black
black
Rocker
white
black
–
–
–
orange transp.
Diagram
Thermal overload protection
1-pole
2-pole
P2
P2
P1
4
3
6
Without illumination
With illumination
8
EMC Products
220…240 V
110…120 V
P1
3
ABT
ABD
A12
A14
A32
A34
5145
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Configuration code (Order example)
Type
Configuration code TA45
514 5 - ABTWF150C0 - 0 0 0 - 111 - 10 - 0 0
Optional Variants
00 standard
21 V-Lock notch
Terminal PE
0 without (PCII)
1 QC 6.3x0.8
Terminal L and N
1 QC 6.3x0.8, without connection to TA45
3 Connection to TA45 non insulated
Metal Shield Filter
0 with metal shield (PCI)
1 without metal shield (PCI and PCII)
Type of mains fi lter / capacitor / bleed resistor
1 standard
X2,Y2
without
3 medical M5
X2
with
2)
Rated current
1 1A
2 2A
3 3A
4 4A
5 6A
6 8A
7 10A
8 15A
1) Not in conjunction with PC II
2) The rated current of the mains filter must not be less than
the tripping current of the circuit breaker for equipment.
Only the rated filter current is shown in the item description on the packaging.
EMC Products
1)
9
5145
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Configuration code TA45
Type
• Circuit Breaker of Equipment
• 2-pole, rocker actuated
• Quick connect terminal
Other types on request
Configuration code TA45
5 145 -A B T WF 15 0C 0 - 0 0 0 - 111 - 10 - 0 0
Without release: code C0
Undervoltage release
P2
P2
P1
Remote trip release
P1
b
U<
U<
P2
ba
P2
P1
c P1
U<
Rated
voltage Un
U
E
Z
A
Code
•
•
•
•
2
240 V AC
•
•
•
•
3
230 V AC
•
•
•
•
4
120 V AC
Rated current circuit breaker of equipment
In
Code
In
Code
In
Code
In
Code
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1,0
1,1
1,2
J01
J02
J03
J04
J05
J06
J07
J08
J09
J10
J11
J12
1,3
1,4
1,5
1,6
1,7
1,8
1,9
2,0
2,1
2,2
2,3
2,5
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J25
2,8
3,0
3,5
4,0
4,5
5,0
6,0
6,5
7,0
7,5
8,0
9,0
J28
030
035
040
045
050
060
065
070
075
080
090
10,0
11,0
12,0
13,0
14,0
15,0
20,0
100
110
120
130
140
150
200
Rocker legend
Surface
printed
Colour of print
printed
printed
white
M
printed
black
P
printed
I
O
white
R
printed
I
O
black
l
ON ON
l
K
L
O OFF OFF O
H
Illustration
O
embossed
l
F
Position of the rocker legend e.g F
white
black
Colours
Switch front
W
B
6
black
black
black
Rocker
white
black
–
–
–
orange transp.
Diagram
Thermal overload protection
1-pole
2-pole
P2
P2
P1
4
3
6
Without illumination
With illumination
10
EMC Products
220…240 V
110…120 V
P1
3
ABT
ABD
A12
A14
A32
A34
5145
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Packaging unit
20 Pcs
Accessories
Description
Assorted_Covers
Rear Cover
0859.0074
RC320
Rear Cover for Power Entry Module
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I
4787
4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder / Quick Connect, 10 A, Suitable for appliances with
protection class I
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4782
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4300-06
4781 Mounting: Power Cord, Cable, Connector: IEC C15
4781
4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15
4784
Mating Outlets/Connectors shuttered
Power Cord Overview complete
VAC17KS, V-Lock cord retaining, diverse m, Connector IEC C17, diverse, black / grey / white
VAC17KS
15.08.2023
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
EMC Products
11