0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
5500.2093

5500.2093

  • 厂商:

    SCHURTER

  • 封装:

    -

  • 描述:

    FILTER LINE PWR MED M80 10A QC

  • 数据手册
  • 价格&库存
5500.2093 数据手册
FMLB-41 1-Phase Line Filters https://www.schurter.com /PG84 AC Filter Cost Optimized See below: Approvals and Compliances Description - Line filter in standard and medical version - 1‑stage - standard attenuation Characteristics - Designed for standard applications - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - Suitable for use in equipment according to IEC/UL 62368-1 Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP) Other versions on request - Version with varistor for overvoltage protection References Alternative: Standard version   We recommend for new applications the type   FMAB NEO  Weblinks pdf data sheet, html datasheet, General Product Information, Approvals, Distributor-Stock-Check, Detailed request for product, Microsite Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category Protection Class Terminal Material: Housing   1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz standard < 0.25 mA (250 V / 60 Hz) 1.7 kVDC between L-N 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 °C to 100 °C Line Filter MTBF Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 200'000 h acc. to MIL-HB-217 F 25/100/21 acc. to IEC 60068-1 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Nickel plated steel Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. EMC Products 1 FMLB-41 1-Phase Line Filters https://www.schurter.com /PG84 Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: FMLB Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40004673 UL Approvals UL UL File Number: E72928 Design Standard Description Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Design Standard Description Designed for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. UKCA declaration of conformity SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP) Product standards Product standards that are referenced Organization Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification 2 EMC Products FMLB-41 1-Phase Line Filters https://www.schurter.com /PG84 max 42 3.2 1) 2) 13 ±0.5 max 25.5 37 ±0.5 max 46 6.3x0.8 (5x) max 66 max 29.5 Dimension [mm] 4 1) Line 2) Load Diagrams Standard version 1) Medical Version (M5) 2) 1) 1) Line 2) Load 2) 1) Line 2) Load Medical Version (M80) 1) 2) 1) Line 2) Load EMC Products 3 FMLB-41 https://www.schurter.com /PG84 Attenuation Loss - - - - 50Ω differential mode _____ 50Ω common mode 1-Phase Line Filters Standard version 1A 2A 4A 6A 2A 4A 6A 2A 4A 6A 10 A Medical version (M5) 1A 10 A Medical version (M80) 1A 10 A 4 EMC Products FMLB-41 1-Phase Line Filters https://www.schurter.com /PG84 All Variants Filter-Type Leakage Current [mA] L [mH] Cx (X2) [nF] Cy (Y2) [nF] Weight [g] Housing 1 Standard version 0.25 2 x 10 68 2.2 50 g 41 5500.2026 █ 2 Standard version 0.25 2x4 68 2.2 50 g 41 5500.2027 █ 4 Standard version 0.25 2 x 1.5 68 2.2 50 g 41 5500.2028 █ 6 Standard version 0.25 2 x 0.8 68 2.2 65 g 41 5500.2029 █ 10 Standard version 0.25 2 x 0.3 68 2.2 65 g 41 5500.2030 █ 1 Medical Version (M5) 0.005 2 x 10 68 - 50 g 41 5500.2077 2 Medical Version (M5) 0.005 2x4 68 - 50 g 41 5500.2078 █ 4 Medical Version (M5) 0.005 2 x 1.5 68 - 50 g 41 5500.2079 █ 6 Medical Version (M5) 0.005 2 x 0.8 68 - 65 g 41 5500.2080 █ 10 Medical Version (M5) 0.005 2 x 0.3 68 - 65 g 41 5500.2081 █ 1 Medical Version (M80) 0.08 2 x 10 68 0.47 50 g 41 5500.2089 Rated Current [A] Order Number 2 Medical Version (M80) 0.08 2x4 68 0.47 50 g 41 5500.2090 4 Medical Version (M80) 0.08 2 x 1.5 68 0.47 50 g 41 5500.2091 6 Medical Version (M80) 0.08 2 x 0.8 68 0.47 65 g 41 5500.2092 10 Medical Version (M80) 0.08 2 x 0.3 68 0.47 65 g 41 5500.2093 █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER 25 Pcs  09.01.2022 Packaging unit  The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. EMC Products 5
5500.2093 价格&库存

很抱歉,暂时无法提供与“5500.2093”相匹配的价格&库存,您可以联系我们找货

免费人工找货