Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Inlet C20 with Circuit Breaker TA35 1-pole
636
C20
70° C
Description
- Panel Mount: Snap-in version from front side - 2 Functions: Appliance Inlet, Protection class I, Circuit breaker type TA35, 1-pole - Quick connect terminals 6.3 x 0.8 mm - Alternative: version for 10 A (15 A) 6135 - Substitute for type 1624-K
Characteristics
- Unwired - Switch non-illuminated or illuminated Thermal overload protection - Qualified for use in equipment according IEC/EN 60950
Other versions on request
Approvals
- Pre-wired version - Quick-connect terminals 4.8 x 0.8 mm - Protection class II, 70°C
- VDE License Number: 40025196 - UL License Number: E96454
References Weblinks
General Product Information Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check, Distributor-Stock-Check
Technical Data
Ratings IEC Ratings UL/CSA Dielectric Strength 16 A / 250 VAC; 50 Hz 20 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 °C to 60 °C from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Snap-in: 1.5/ 2/ 2.5 mm Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet C20 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 16 A, Protection class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 1-pole rocker switch, illuminated or nonilluminated. Conditional short circuit Inc: 2000 A
Circuit breaker
Allowable Operation Temp. Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing
Appliance Inlet
636
www.schurter.com/pg05 Dimensions
Length 53.6 mm
Power entry modules without line filter
10.6 53.6
30.5 S ±0.05
37 50.8
+0.2 0
43 x 50.6
43.2 0
46
+0.2
max. R 2
R3
19
1.5
PE N
1) Line 2) Load
PE' N'
TA35
PE N
1) Line 2) Load
PE' N'
TA35
Diagrams non-illuminated L' L 1)
P1
4 2)
illuminated (connection N' to L) L' P1 4 L 1) 2)
L
Appliance Inlet
Power entry modules without line filter www.schurter.com/pg05
ORDER CODE
Number of switched poles Number of protected poles 1-pole 1
LINE
P1
636
Table 1 Selection for type TA35 Order example
L
4
LOAD
TA35-
CFT
W
F
120
C0
Switch
without illumination illuminated 240 V 120 V
CFT No other features
Switch
C2F C4F
Other versions on request
Colours
Switch front W B 3 4 6 black black black black black Rocker
non-illuminated illuminated
white black – – –
– – red transparent green transparent orange transparent
Other colours on request
Rocker legend
Surface F H K L embossed printed printed printed Illustration
0 l
Colour of print
OFF OFF
ON
white black white black
ON l l
M printed
Other legends on request
0
0
Position of the rocker legend e.g. F
Rated current In (A)
In 1,0 2,0 4,0 5,0 6,0 Code J10 J20 040 050 060 In 8,0 10,0 12,0 15,0 16,0 20,0 Code 080 100 120 150 160 200*
Other rated currents on request
*) UL / CSA only
Appliance Inlet
3
636
www.schurter.com/pg05
Technical data (continued) Circuit breaker
Tripping characteristics In < 3 A
[ min ] [ sec ] 10'000
Type p Rated current Ambient temp. TA35 3 ... 20 A
[ min ] [ sec ] 10'000
Type Rated current Ambient temp. TA35 > 3–20A (TC-1, TC-2) +23 °C
60 30 20 10 5 200 100 1 50 2`000 1`000 500
60 30 20 10 5 200 100 1 50 2`000 1`000 500
20 10 5 2 1 0,5 Tr ipping time
Tr ipping time
20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 10 Multiple of rated current [ x In ]
0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 10 Multiple of rated current [ x In ]
Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for lower or higher ambient temperature, use a correction factor from the table below. * Ambient temperature [°C] –25 –20 0 +23 +40 +50 +60 Correction factor 0.79 0.81 0.90 1.00 1.03 1.04 1.06 * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. Example: Rated current at +23 °C Ambient temperature Correction factor Chosen rated current at +60 °C ambient temperature:
10 A +60 °C 1.06 10 A x 1.06 = 10.6 A
Order code (Order example) Type Order code TA35
Wiring 1 wired 0 unwired
6136
CFTWF120C0 see table 1
.0210
Terminals 1 Quick connect 6.3 x 0.8 mm Mounting 2 Snap-in s = 1.5 mm 3 Snap-in s = 2.0 mm 4 Snap-in s = 2.5 mm 0 Protection class 1
Please note that Schurter will establish an internal part number for logistics use in addition to the order code. The format of this internal part number is, for example: 6136.xxxx.xxxx
Appliance Inlet
Power entry modules without line filter www.schurter.com/pg05 Packaging unit
15 Pcs
636
Mating Outlets/Connectors
Category / Description
Connector IEC Connector C19, Rewireable, Straight IEC Connector C19, Rewireable, Angled IEC Connector C19, Rewireable, Straight IEC Connector C19, Rewireable, Angled IEC Connector C19, Rewireable, Straight 0104 1651 1652 4790 4795
Power Cord Power Cord with IEC Connector C19, Straight 1654
Power Supply or Interconnection Cord Diverse Netzanschluss- oder Netzweiterverbidungsleitung 16 A 6009.5195
The specifications, descriptions and illustrations indicated in this document are based on Appliance Inlet current information. All content is subject to modifications and amendments.
5