    6136.0411 - IEC Appliance Inlet C20 with Circuit Breaker TA35 1-pole - Schurter Inc.

  • 数据手册
  • 价格&库存
6136.0411 数据手册
Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Inlet C20 with Circuit Breaker TA35 1-pole 636 C20 70° C Description - Panel Mount: Snap-in version from front side - 2 Functions: Appliance Inlet, Protection class I, Circuit breaker type TA35, 1-pole - Quick connect terminals 6.3 x 0.8 mm - Alternative: version for 10 A (15 A) 6135 - Substitute for type 1624-K Characteristics - Unwired - Switch non-illuminated or illuminated Thermal overload protection - Qualified for use in equipment according IEC/EN 60950 Other versions on request Approvals - Pre-wired version - Quick-connect terminals 4.8 x 0.8 mm - Protection class II, 70°C - VDE License Number: 40025196 - UL License Number: E96454 References Weblinks General Product Information Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check, Distributor-Stock-Check Technical Data Ratings IEC Ratings UL/CSA Dielectric Strength 16 A / 250 VAC; 50 Hz 20 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 °C to 60 °C from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Snap-in: 1.5/ 2/ 2.5 mm Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet C20 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 16 A, Protection class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 1-pole rocker switch, illuminated or nonilluminated. Conditional short circuit Inc: 2000 A Circuit breaker Allowable Operation Temp. Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing Appliance Inlet  636 www.schurter.com/pg05 Dimensions Length 53.6 mm Power entry modules without line filter 10.6 53.6 30.5 S ±0.05 37 50.8 +0.2 0 43 x 50.6 43.2 0 46 +0.2 max. R 2 R3 19 1.5 PE N 1) Line 2) Load PE' N' TA35 PE N 1) Line 2) Load PE' N'  TA35 Diagrams non-illuminated L' L 1) P1 4 2) illuminated (connection N' to L) L' P1 4 L 1) 2) L Appliance Inlet Power entry modules without line filter www.schurter.com/pg05 ORDER CODE Number of switched poles Number of protected poles 1-pole 1 LINE P1 636 Table 1 Selection for type TA35 Order example L 4 LOAD TA35- CFT W F 120 C0 Switch without illumination illuminated 240 V 120 V CFT No other features Switch C2F C4F Other versions on request Colours Switch front W B 3 4 6 black black black black black Rocker non-illuminated illuminated white black – – – – – red transparent green transparent orange transparent Other colours on request Rocker legend Surface F H K L embossed printed printed printed Illustration 0 l Colour of print OFF OFF ON white black white black ON l l M printed Other legends on request 0 0 Position of the rocker legend e.g. F Rated current In (A) In 1,0 2,0 4,0 5,0 6,0 Code J10 J20 040 050 060 In 8,0 10,0 12,0 15,0 16,0 20,0 Code 080 100 120 150 160 200* Other rated currents on request *) UL / CSA only Appliance Inlet 3 636 www.schurter.com/pg05 Technical data (continued) Circuit breaker Tripping characteristics In < 3 A [ min ] [ sec ] 10'000 Type p Rated current Ambient temp. TA35 3 ... 20 A [ min ] [ sec ] 10'000 Type Rated current Ambient temp. TA35 > 3–20A (TC-1, TC-2) +23 °C 60 30 20 10 5 200 100 1 50 2`000 1`000 500 60 30 20 10 5 200 100 1 50 2`000 1`000 500 20 10 5 2 1 0,5 Tr ipping time Tr ipping time 20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 10 Multiple of rated current [ x In ] 0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 10 Multiple of rated current [ x In ] Effect of ambient temperature The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for lower or higher ambient temperature, use a correction factor from the table below. * Ambient temperature [°C] –25 –20 0 +23 +40 +50 +60 Correction factor 0.79 0.81 0.90 1.00 1.03 1.04 1.06 * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. Example: Rated current at +23 °C Ambient temperature Correction factor Chosen rated current at +60 °C ambient temperature: 10 A +60 °C 1.06 10 A x 1.06 = 10.6 A Order code (Order example) Type Order code TA35 Wiring 1 wired 0 unwired 6136 CFTWF120C0 see table 1 .0210 Terminals 1 Quick connect 6.3 x 0.8 mm Mounting 2 Snap-in s = 1.5 mm 3 Snap-in s = 2.0 mm 4 Snap-in s = 2.5 mm 0 Protection class 1 Please note that Schurter will establish an internal part number for logistics use in addition to the order code. The format of this internal part number is, for example: 6136.xxxx.xxxx  Appliance Inlet Power entry modules without line filter www.schurter.com/pg05 Packaging unit 15 Pcs 636 Mating Outlets/Connectors Category / Description Connector IEC Connector C19, Rewireable, Straight IEC Connector C19, Rewireable, Angled IEC Connector C19, Rewireable, Straight IEC Connector C19, Rewireable, Angled IEC Connector C19, Rewireable, Straight 0104 1651 1652 4790 4795 Power Cord Power Cord with IEC Connector C19, Straight 1654 Power Supply or Interconnection Cord Diverse Netzanschluss- oder Netzweiterverbidungsleitung 16 A 6009.5195 The specifications, descriptions and illustrations indicated in this document are based on Appliance Inlet current information. All content is subject to modifications and amendments. 5
6136.0411 价格&库存

很抱歉,暂时无法提供与“6136.0411”相匹配的价格&库存,您可以联系我们找货

免费人工找货