5091
Connectors (Inlets/Outlets)
https://www.schurter.com /PG07
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
Flange with countersunk holes
F
Flange with through holes special type
H
See below:
Approvals and Compliances
70° C
70° C
Description
Weblinks
- Panel mount :
Screw-on mounting , front side
- Connector , Pin temperature 70 °C
- protection class I or II
- Solder / Quick Connect / PCB Terminal
pdf data sheet, html datasheet, General Product Information, Approvals,
Distributor-Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temperature
IP-Protection
Protection against electric
shock
Terminal
Material: Housing
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 4 kVAC between L-N
> 2 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
front side IP20 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Solder / Quick Connect / PCB Terminal
straight
PA6, black or grey, UL 94V-0
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: 5091
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40034887
UL Approvals
UL
UR File Number: E103791
Connectors
1
5091
Connectors (Inlets/Outlets)
https://www.schurter.com /PG07
Product standards
Product standards that are referenced
Organization
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
UL 60320-1
Standard for Attachment Plugs and Receptacles
Design
Standard
Description
Designed for applications acc.
IEC/UL 62368-1
Audio/video, information and communication technology equipment - Part
1: Safety requirements
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
UKCA declaration of conformity
SCHURTER AG
The UKCA marking declares that the product complies with the applicable
requirements laid down in the British Amendment of Regulation (EC)
765/2008.
RoHS
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
Dimensions [mm]
35
26.1
24
15.6
15.8 - 0
+0.2
45
ø
2
3.
35
23
Flange with countersunk holes
2
Connectors
4
18.1
+0.2
23.2 - 0
5091
Connectors (Inlets/Outlets)
https://www.schurter.com /PG07
44.5
26.3
35
4
24
5.6
0.9
.5
7
ø1
.2
ø3
7
35
18.2
ø10
Flange with through holes special type
Config. Code
5091|-|H|-|A|B|C|0-|D|-|E|
The characters are placeholders for the correspondingly keys of selections from the key tables.
5091|-| H |-|A|B|C|0-|D|-|E| = Type
5091|-|H|-|A|B| C |0-|D|-|E| = Terminals
Type
Configuration
key
Terminal Ground
Configuration
key
protection class II
B
without terminal
0
protection class I
X
solder terminal
1
PCB-terminal standard
4
Blade terminal (6.3 x 0.8 mm)
9
5091|-|H|-| A |B|C|0-|D|-|E| = Terminals
Symbols similar as in table A
Terminal L
Configuration
key
solder terminal
1
PCB-terminal standard
4
5091|-|H|-|A|B|C|0-| D |-|E| = Color
Color
Configuration
key
Black
A
Grey
B
Blade terminal (6.3 x 0.8 mm)
9
Style
5091|-|H|-|A| B |C|0-|D|-|E| = Terminals
Terminal N
5091|-|H|-|A|B|C|0-|D|-| E | = Style
Configuration
key
solder terminal
1
PCB-terminal standard
4
Blade terminal (6.3 x 0.8 mm)
9
Configuration
key
flange with countersunk holes
1
flange with through holes
2
flange with through holes (special type)
7
Symbols similar as in table A
Connectors
3
5091
Connectors (Inlets/Outlets)
https://www.schurter.com /PG07
All Variants
Type
Terminals L / N
Terminal Ground
Color
Style
Features
Config. Code
Protection class I
solder terminal
solder terminal
black
Flange with countersunk holes
-
5091-X-1110-A-1
6182.0001
Protection class I
solder terminal
solder terminal
grey
Flange with countersunk holes
-
5091-X-1110-B-1
6182.0002
Protection class I
PCB-terminal
(standard)
PCB-terminal
(standard)
black
Flange with through holes
special type
-
5091-X-4440-A-7
6182.0004
Protection class I
PCB-terminal
(standard)
PCB-terminal
(standard)
grey
Flange with through holes
special type
-
5091-X-4440-B-7
6182.0005
Protection class I
Blade terminal (6.3
x 0.8 mm)
Blade terminal (6.3
x 0.8 mm)
black
Flange with countersunk holes
-
5091-X-9990-A-1
6182.0006
Protection class I
Blade terminal (6.3
x 0.8 mm)
Blade terminal (6.3
x 0.8 mm)
grey
Flange with countersunk holes
-
5091-X-9990-B-1
6182.0008
The listed variants should be available from stock. Other versions on request www.schurter.com/contact
█ Most Popular.
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Packaging unit
100 Pcs
Mating Inlets/Plugs
Category / Description
Appliance Inlet Overview complete
6100-3, Mounting: Screw, Solder / Quick Connect, Appliance Inlet: IEC C14
6100-3
6100-4, Mounting: Snap-in, Solder / Quick Connect, Appliance Inlet: IEC C14
6100-4
6130, Mounting: Snap-in, Appliance Inlet, IEC C14, For PCB mounting, IP30, Meets the glow wire test acc. IEC 60335-1
6130
edition 4, 7/7.3, Suitable for appliances with protection class I
G-Stecker, Mounting: Appliance Inlet : IEC C14 Without fuse holder
6150
6010, Mounting: Snap-in, Solder / quick-connect / screw / PCB, Appliance Inlet: IEC C14
6010
...
Distribution Unit Overview complete
0712-PQ, Mounting: Snap-in, Front Side, Solder terminal (4.8 x 0.8 mm), 1x Appliance Outlet: IEC F
0712
4741, Mounting: 2x Appliance Outlet: IEC F
4741
4747, Mounting: 4x Appliance Outlet: IEC F
4747
4740, Mounting: 6x Appliance Outlet: IEC F
4740
IEC Inlet Filter Overview complete
GRF2, Mounting: Rear Side, With EMC-shield and without line filter, 10 A, Plug Connector, Appliance Inlet: IEC C14,
Suitable for appliances with protection class I
GRF2
5110, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Thermoplastic
Appliance Inlet: IEC C14, prewired, Suitable for appliances with protection class I
5110
KFS, Mounting: Screw, Front Side, Filter: Standard version, Without fuse holder: 10 A, Appliance Inlet: IEC C14, prewired
KFS
4
Connectors
Order Number
█
5091
Connectors (Inlets/Outlets)
https://www.schurter.com /PG07
Category / Description
Power Entry Module Overview complete
DF11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 6.3 x 0.8
mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I or II 0 DF11,
Mounting:Screw, Quick connect terminals 6.3 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I or II 0 DF11,
Power Entry ModuleC14, 55°C, version: L: N: ground: : fuseholder: color: design: dimension S: features: 0 DF11, Moun- DF11
ting: Snap-in/screw-on, Appliance Inlet: IEC C14, Without fuse holder: : black, Suitable for appliances with protection
class I or II 0 DF11, Mounting: Snap-in/screw-on8 mm, Quick connect terminals 6.3 x 0.8 mm, IP40,: black, Appliance
Inlet: IEC C14, Circuit Breakers TA45, A, non-illuminated, Protection Class I or II 0 DF11, Mounting: Snap-in/screw-on,
mm, Without fuse holder: : IEC Suitable for appliances with protection class I or II 0
DD11, Mounting: Screw-on mounting, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals
4.8 x 0.8 mm, Appliance Inlet: IEC C14, With or without protection cover, Fuseholder: 1-/2-pole, Suitable for appliances DD11
with protection class I
DD21, Mounting: Screw-on mounting Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, additional quick
DD21
connect 4.8 x 0.8 mm Appliance Inlet: IEC C14, Fuseholder: 1-/2-pole
DC11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 1-/2-pole, Quick connect terminals 4.8 x 0.8
mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I or II
DC11
KEB2, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or
illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I
KEB2
...
Power Entry Module with line filter Overview complete
DG12, Mounting : Screw, 8 mm, 15 A, prewired, Standard and Medical Version, Appliance Inlet: IEC C14 C18, Circuit
Breakers TA35: DG12, Suitable for appliances with protection class I or II
DG12
DD14, Mounting: Screw-on mounting, Front Side, Filter, Standard and Medical Version, Fuseholder:1-/2-pole, 10 A,
Rocker switch: 2-pole, non-illuminated Appliance Inlet: IEC C14, prewired
DD14
KFB1, Mounting: Screw, Front Side, Filter: Standard version, Without fuse holder: 10 A, Rocker switch: 1-pole, Appliance Inlet: IEC C14, prewired
KFB1
KFB2, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Rocker switch:
2-pole, Appliance Inlet: IEC C14, prewired
KFB2
DC12, Mounting: Screw, Front-/Rear-Side, Filter, Standard and Medical Version, Without fuse holder:10 A, Rocker
switch: 1-/2-pole, non-illuminated or illuminated Appliance Inlet: IEC C14, prewired
DC12
09.03.2022
...
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Connectors