DC11
Power entry modules without line filter
https://www.schurter.com /PG05
IEC Appliance Inlet C14 or C18 with Line Switch 1- or 2-pole
Screw-on mounting
non-illuminated
from front side
C14
Snap-in version
non-illuminated
Screw-on mounting and line Switch illuminated
green
C18
See below:
Approvals and Compliances
70° C
70° C
Description
Characteristics
Unique Selling Proposition
Other versions on request
- Panel mount :
Screw-on version from front or rear side, snap-in version front side
- Appliance Inlet protection class I or II , Line Switch 1‑ or 2‑pole
- V-Lock notch standard
- Quick connect terminals 4.8 x 0.8 mm
- Ultra compact design
- Line switch for high inrush currents
- Components internally wired
- V-Lock cord retaining
- All single elements are already wired
- Unwired versions available on request
- Line switch non-illuminated or illuminated
- Ideal for application with high transient loads
- Suitable for use in equipment according to IEC/UL 62368-1
- Unwired versions
- Solder terminals
- Line switch with other rocker marking
References
Alternative: version with line filter DC12
Substitute for type KEB1; KEB2; 6010-K
Weblinks
pdf data sheet, html datasheet, General Product Information, Approvals,
Distributor-Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temperature
IP-Protection
Protection against electric
shock
Terminal
Panel Thickness S
Material: Housing
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
Appliance inlet/-outlet
Line Switch
C14 / C18 acc. to IEC 60320-1,
UL 60320-1, CSA C22.2 no. 60320-1
(for cold conditions) pin-temperature 70
°C, 10 A, Protection Class I or II
Rocker switch 1-/2-pole, non-illuminated or illuminated, acc. to IEC 61058-1
Technical Details
front side IP40 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
Screw: max 6 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1/1.5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.
Connectors
1
DC11
Power entry modules without line filter
https://www.schurter.com /PG05
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: DC11
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40007009
UL Approvals
UL
UL File Number: E96454
CCC Approvals
CCC
CCC Certificate Number: 2013010204594013
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
IEC 61058-1
Switches for appliances. Part 1. General requirements
Designed according to
UL 60320-1
Standard for Attachment Plugs and Receptacles
Designed according to
CSA C22.2 no. 60320-1
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Design
Standard
Description
Designed for applications acc.
IEC/UL 62368-1
Audio/video, information and communication technology equipment - Part
1: Safety requirements
Designed for applications acc.
IEC 60335-1
Safety of electrical appliances for household and similar purposes. Meets
the requirements for appliances in unattended use. This includes the
enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12
& -13.
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
UKCA declaration of conformity
SCHURTER AG
The UKCA marking declares that the product complies with the applicable
requirements laid down in the British Amendment of Regulation (EC)
765/2008.
RoHS
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
SCHURTER AG
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
SCHURTER AG
Meets the requirements of IEC 60335-1 for appliances in unattended use.
This includes the enhanced requirements of glow wire tests acc. to IEC
60695-2-11 or -12 &-13.
Product standards
Product standards that are referenced
Organization
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
White Paper Glow wire test
2
Connectors
DC11
Power entry modules without line filter
https://www.schurter.com /PG05
Dimensions [mm]
Screw-on mounting
27.3
R 2.5
32.3
2.2
R 3.8
34
1)
9.65
31.3
31.15
R6
3.2
6.3x90°
R4
9.8
1.35
36
17.9
4.2
27
44
R 2.4 ±0.10
31.6 ±0.10
3.6/M3
2)
27.6 ±0.10
36
±0.10
1) 1-pol non-illuminated
2) 2-pol illuminated, 2-pol non-illuminated
Snap-in mounting
32.3
2.2
R 3.8
31.15
R 2.5
1)
30
1.35
9.65
34
27.3
31.3
R4
9.8
17.9
4.2
S
27
±0.1
31.6 ±0.10
R 2.4 ±0.10
2)
27.6 ±0.10
1) 1-pol non-illuminated
2) 2-pol illuminated, 2-pol non-illuminated
Connectors
3
DC11
Power entry modules without line filter
https://www.schurter.com /PG05
Diagrams
Line switch non-illuminated 2-pole
1)
2
L
2)
PE'
PE
1
N
1) Line
2) Load
Line switch illuminated 2-pole
1)
L
Line switch non-illuminated 1-pole
2
PE
2)
PE'
N
1
1) Line
2) Load
1)
2
L
2)
PE'
PE
1
N
1) Line
2) Load
All Variants
Rated Current UL
Protection Class
Panel mounting
Panel Thickness
s [mm]
Line Switch
Illumination
Color
Order Number
15
I
Snap-in
1.5
2-pole
l
red
DC11.0021.201
15
I
Snap-in
1.5
2-pole
l
red
DC11.0021.206
15
I
Snap-in
2
2-pole
l
red
DC11.0021.301
15
I
Snap-in
2.5
2-pole
l
red
DC11.0021.401
15
I
Snap-in
1.5
2-pole
l
green
DC11.0031.201
15
I
Snap-in
2
2-pole
l
green
DC11.0031.301
15
I
Snap-in
2.5
2-pole
l
green
DC11.0031.401
15
I
Snap-in
1.5
1-pole
-
DC11.0001.203
15
I
Snap-in
1.5
1-pole
-
DC11.0001.207
15
I
Snap-in
2
1-pole
-
DC11.0001.303
15
I
Snap-in
2.5
1-pole
-
DC11.0001.403
15
I
Snap-in
1.5
2-pole
-
DC11.0001.201
15
I
Snap-in
1.5
2-pole
-
DC11.0001.206
15
I
Snap-in
2
2-pole
-
DC11.0001.301
15
II
Snap-in
2
2-pole
-
DC11.0001.351
15
I
Snap-in
2.5
2-pole
-
3-107-445
15
I
Snap-in
2.5
2-pole
-
DC11.0001.401
█
█
█
█
█
15
I
Snap-in
3
2-pole
-
DC11.0001.501
15
I
Screw
-
2-pole
l
red
DC11.0021.001
15
I
Screw
-
2-pole
l
red
DC11.0021.006
15
I
Screw
-
2-pole
l
green
DC11.0031.001
█
15
I
Screw
-
1-pole
-
DC11.0001.003
█
15
I
Screw
-
1-pole
-
DC11.0001.007
15
I
Screw
-
2-pole
-
DC11.0001.001
15
I
Screw
-
2-pole
-
DC11.0001.006
█ Most Popular.
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
With screw mounting on PCB, 2 screws are included
All variants according VDE (ENEC 10) approved for 10 A
Packaging unit
4
50 Pcs
Connectors
█
█
DC11
Power entry modules without line filter
https://www.schurter.com /PG05
Accessories
Description
Wire Harness
Wire harness for SCHURTER products
Assorted Covers
Rear Cover
0859.0047
4311.9403
RC320
Rear Cover for Power Entry Module
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Countersunk, B
4700.0002
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I
4787
4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder / Quick Connect, 10 A, Suitable for appliances with
protection class I
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4782
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4300-06
4781 Mounting: Power Cord, Cable, Connector: IEC C15
4781
4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15
4784
...
Connectors
5
DC11
Power entry modules without line filter
https://www.schurter.com /PG05
Category / Description
Power Supply Cord Overview complete
Cord Sets 10 A, Europlug, 2.5 m, Connector IEC C13, H05VV-F3G1.0, black
6004.0215
Cord Sets 10 A, Europlug, 2.5 m, Connector IEC C13, H05VV-F3G1.0, black
6003.0215
Mating Outlets/Connectors shuttered
Connector Overview complete
4783 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4783
Power Cord Overview complete
VAC13KS, Overview, V-Lock cord retaining, diverse Connector IEC C13, diverse, black
VAC13KS
VAC17KS, V-Lock cord retaining, diverse m, Connector IEC C17, diverse, black / grey / white
VAC17KS
15.09.2021
6
Connectors
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.