DF11
Power entry modules without line filter
https://www.schurter.com /PG05
IEC Appliance Inlet C14 or C18 with recessed Circuit Breaker TA45
Screw-on version from front or rear side
Rocker illuminated
orange
C14
Snap-in mounting from front side
Rocker non-illuminated
white
C18
See below:
Approvals and Compliances
70° C
70° C
Description
- Panel mount :
Screw-on version from front or rear side, snap-in version front side
- 2 Functions :
Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
- All single elements are already wired
- Circuit Breaker non-illuminated or illuminated
- Suitable for use in equipment according to IEC/UL 62368-1
Other versions on request
- Unwired versions
- Other rocker marking
- Variant with notch for V-Lock mating Cordsets
References
Alternative: version with line filter DF12
Substitute for type 6145
Weblinks
pdf data sheet, html datasheet, General Product Information, Approvals,
Distributor-Stock-Check, Accessories, Detailed request for product
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temperature
IP-Protection
Protection against electric
shock
Terminal
Panel Thickness S
Material: Housing
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-10 °C to 55 °C
front side IP40 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1/1.5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance inlet/-outlet
Circuit Breakers
C14 / C18 acc. to IEC 60320-1,
UL 60320-1, CSA C22.2 no. 60320-1
(for cold conditions) pin-temperature 70
°C, 10 A, Protection Class I or II
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.
Connectors
1
DF11
Power entry modules without line filter
https://www.schurter.com /PG05
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: DF11
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40011305
UL Approvals
UL
UR File Number: E96454
CCC Approvals
CCC
CCC Certificate Number: 2020180204013620
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
UL 60320-1
Standard for Attachment Plugs and Receptacles
Designed according to
CSA C22.2 no. 60320-1
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Design
Standard
Description
Suitable for applications acc.
IEC/UL 62368-1
Audio/video, information and communication technology equipment - Part
1: Safety requirements
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
UKCA declaration of conformity
SCHURTER AG
The UKCA marking declares that the product complies with the applicable
requirements laid down in the British Amendment of Regulation (EC)
765/2008.
RoHS
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
SCHURTER AG
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
Product standards
Product standards that are referenced
Organization
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
2
Connectors
DF11
Power entry modules without line filter
https://www.schurter.com /PG05
Dimensions [mm]
Screw-on mounting
76.7
28.2
29 ±0.10
73.5 ±0.10
73.2
37.1
2.3
41.7
72.7
10.6
82.5
91.5
28.7
82.5 ±0.10
32.5
.05
±0
9.4
9.15
6
Ø 3.3
55
2.
R
27.9
/M
ø
0.8
Ø 6.4
3
4.5 ±0.05
9.7
R
R
R 2.8
7
4.
R
4.5
9.45
5
2.9
3.6
4.8
Snap-in version
76.7
2.3
41.7
28.2
29 ±0.10
73.5 ±0.10
73.2
37.1
77
10.6
72.7
28.7
.05
2.15
9.7
1.9
S ±0.1
27.9
55
2.
32.5
R
R
R 2.8
7
4.
R
9.45
±0
5
2.9
4.8
* --- Version TA45 with undervoltage release
Connectors
3
DF11
Power entry modules without line filter
https://www.schurter.com /PG05
Diagrams
L' P1
L
1)
2)
PE
PE'
N
N' P2
1) Line
2) Load
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient Temperature [°C]
Correction factor
-10
0.89
-5
0.91
0
0.92
+23
1.00
+30
1.03
+40
1.08
+55
1.16
Example: With a nominal current of 5A and an ambient temperature of 40°C, a correction
factor of 1.08 results. This results in a nominal current of 5.5 A, which is rounded up to the
next higher nominal current 6 A.
Time-Current-Curves
Tripping Characteristics In ≥ 3 ... ≤ 15 A
Tripping Characteristics In < 3 A
[ min ] [ sec ]
10’000
[ min ] [ sec ]
10’000
Type
TA45
Type
Rated current
In < 3 A
Rated current
60
2000
30
20
1000
10
Ambient temp.
1-pole pr otected
60
2- pole protected
30
2’000
+23 °C
Ambient temp.
500
5
5
200
200
100
1
100
1
50
20
20
10
10
5
5
2
2
1
1
0,5
0,5
Tripping time
Tripping time
50
0,3
0,2
0,1
1,05 1,32
2
Multiple of rated curr ent
4
2- pole protected
1’000
10
500
I n > 3... < 15 A
1-pole p rotected
20
+23 °C
TA45
3
4
5
8
10
[ x In ]
Connectors
0,3
0,2
0,1
1,05 1,32
2
Multiple of rated cur rent
3
4
5
8
[ x In ]
10
DF11
Power entry modules without line filter
https://www.schurter.com /PG05
Order number key
Configuration code (Order example)
Type
Configuration code TA45
DF11 - ABTWF150C0 - 000 - 111 - 009
Optionale Variants
0 Standard
9 V-Lock
Colour
0 Black
Mounting
0 Screw mounting
1 Snap-in mounting s = 1.0 mm
2 Snap-in mounting s = 1.5 mm 3 Snap-in mounting s = 2.0 mm
4 Snap-in mounting s = 2.5 mm 5 Snap-in mounting s = 3.0 mm
Terminal PE
0 Without terminal (PCII)
1 Quick-connect terminal 6.3x0.8 mm
Terminal N
1 Quick-connect terminals 6.3x0.8 mm, without connection to TA45
3 Connection to TA45 non insulated
Terminal L
1 Quick-connect terminals 6.3x0.8 mm, without connection to TA45
3 Connection to TA45 non insulated
Connectors
5
DF11
Power entry modules without line filter
https://www.schurter.com /PG05
Configuration code TA45
Type
• Circuit Breaker of Equipment
• 2-pole, rocker actuated
• Quick connect terminal
Other types on request
Configuration code TA45
DF11- ABTWF150C0 - 000 - 111 - 009
Without release: code C0
Undervoltage release
P2
P2
P1
Remote trip release
P1
b
U<
U<
P2
ba
P2
P1
c P1
U<
Rated
voltage Un
U
E
Z
A
Code
•
•
•
•
2
240 V AC
•
•
•
•
3
230 V AC
•
•
•
•
4
120 V AC
Rated current circuit breaker of equipment
In
Code
In
Code
In
Code
In
Code
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1,0
1,1
1,2
J01
J02
J03
J04
J05
J06
J07
J08
J09
J10
J11
J12
1,3
1,4
1,5
1,6
1,7
1,8
1,9
2,0
2,1
2,2
2,3
2,5
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J25
2,8
3,0
3,5
4,0
4,5
5,0
6,0
6,5
7,0
7,5
8,0
9,0
J28
030
035
040
045
050
060
065
070
075
080
090
10,0
11,0
12,0
13,0
14,0
15,0
20,0
100
110
120
130
140
150
200
Rocker legend
Surface
printed
Colour of print
printed
printed
white
M
printed
black
P
printed
I
O
white
R
printed
I
O
black
l
ON ON
l
K
L
O OFF OFF O
H
Illustration
O
embossed
l
F
Position of the rocker legend e.g F
white
black
Colours
Switch front
W
B
6
black
black
black
Rocker
white
black
–
–
–
orange transp.
Diagram
Thermal overload protection
1-pole
2-pole
P2
P2
P1
4
3
6
Without illumination
With illumination
6
Connectors
220…240 V
110…120 V
P1
3
ABT
ABD
A12
A14
A32
A34
DF11
Power entry modules without line filter
https://www.schurter.com /PG05
Packaging unit
20 Pcs
Accessories
Description
Assorted_Covers
Rear Cover
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I
4787
4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder / Quick Connect, 10 A, Suitable for appliances with
protection class I
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4782
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4300-06
4781 Mounting: Power Cord, Cable, Connector: IEC C15
4781
4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15
4784
Mating Outlets/Connectors shuttered
Connector Overview complete
4783 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4783
Power Cord Overview complete
VAC13KS, Overview, V-Lock cord retaining, diverse Connector IEC C13, diverse, black
VAC13KS
11.08.2023
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Connectors