DF11.ABDBL150C0.0010.01 数据手册
DF11
Power entry modules without line filter
https://www.schurter.com /PG05
IEC Appliance Inlet C14 or C18 with recessed Circuit Breaker TA45
C14
C18
See below:
Approvals and Compliances
70° C
70° C
Description
- Panel mount :
Screw-on version from front or rear side, snap-in version from front
side
- 2 Functions :
Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
- All single elements are already wired
- Circuit Breaker non-illuminated or illuminated
- Suitable for use in equipment according to IEC/UL 60950
Other versions on request
- Unwired versions
- Other rocker marking
- Variant with notch for V-Lock mating Cordsets
References
Alternative: version with line filter DF12
Substitute for type 6145
Weblinks
pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product, Microsite
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temperature
IP-Protection
Insulation cover
Terminal
Panel Thickness S
Material: Housing
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-10 °C to 55 °C
appliance inlet/-outlet
Circuit Breakers
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1/1.5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
C14 / C18 acc. to IEC 60320-1,
UL 60320-1, CSA C22.2 no. 60320-1
(for cold conditions) pin-temperature 70
°C, 10 A, Protection Class I or II
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: DF11
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40011305
UL Approvals
UL
UL File Number: E96454
Connectors
1
DF11
Power entry modules without line filter
https://www.schurter.com /PG05
Product standards
Product standards that are referenced
Organization
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
UL 60320-1
Standard for Attachment Plugs and Receptacles
Designed according to
CSA C22.2 no. 60320-1
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Design
Standard
Description
Designed for applications acc.
IEC/UL 60950
IEC 60950-1 includes the basic requirements for the safety of information
technology equipment.
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS
SCHURTER AG
EU Directive RoHS 2011/65/EU
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
MicrositeV-Lock
SCHURTER AG
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
Dimensions [mm]
Screw-on mounting
76.7
2.3
28.2
41.7
29 ±0.10
73.5 ±0.10
72.7
73.2
37.1
82.5
10.6
.05
±0
9.4
9.15
Ø 3.3
0.8
Ø 6.4
2
27.9
Connectors
4.8
55
6
2.
R
R
R
R 2.8
7
4.
R
2.9
3
/M
ø
3.6
4.5 ±0.05
9.7
9.45
5
4.5
91.5
28.7
82.5 ±0.10
32.5
DF11
Power entry modules without line filter
https://www.schurter.com /PG05
Snap-in version
76.7
2.3
41.7
28.2
29 ±0.10
73.5 ±0.10
73.2
37.1
77
10.6
72.7
28.7
.05
1.9
S ±0.1
27.9
55
2.
32.5
R
R
R 2.8
7
4.
R
2.15
9.7
9.45
±0
5
2.9
4.8
* --- Version TA45 with undervoltage release
Diagrams
L
L' P1
1)
2)
PE
N
PE'
N' P2
1) Line
2) Load
Connectors
3
DF11
Power entry modules without line filter
https://www.schurter.com /PG05
Table 1 Selection for type TA45
Order example
ABT
W
• Circuit Breaker of Equipment
• 2-pole, rocker actuated
• Quick connect terminal
Other types on request
Diagram
Thermal overload protection
Without illumination
With illumination
1-pole
2-pole
P2
P2
P1
4
3
P1
3
6
220…240 V
110…120 V
ABT
ABD
A12
A14
A32
A34
}
Colours
Switch front
W
B
6
Rocker
black
black
black
white
black
–
–
–
orange transp.
Rocker legend
K
printed / bedruckt
L
printed / bedruckt
l
printed / bedruckt
white / weiss
Position of the rocker legend
e.g F
Illustration
M
printed
black
P
printed
I
O
white
printed
I
O
black
R
Rated current circuit breaker of equipment
In
Code
In
Code
In
Code
In
Code
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1,0
1,1
1,2
J01
J02
J03
J04
J05
J06
J07
J08
J09
J10
J11
J12
1,3
1,4
1,5
1,6
1,7
1,8
1,9
2,0
2,1
2,2
2,3
2,5
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J25
2,8
3,0
3,5
4,0
4,5
5,0
6,0
6,5
7,0
7,5
8,0
9,0
J28
030
035
040
045
050
060
065
070
075
080
090
10,0
11,0
12,0
13,0
14,0
15,0
20,0
100
110
120
130
140
150
200
Without release: code C0
Undervoltage release
P2
P1
U<
4
P2
Remote trip release
b
U<
P1
Colour of print
l
white / weiss
embossed / Relief
H
Surface
O
l
O
black / schwarz
F
ON
ON
Colour of print
OFF OFF
Illustration
O
Surface
P2
ba
P1
P2
c P1
U<
U
E
Z
A
Code
Rated
voltage Un
•
•
•
•
2
240 V AC
•
•
•
•
3
230 V AC
•
•
•
•
4
120 V AC
Connectors
F
150
C0
DF11
Power entry modules without line filter
https://www.schurter.com /PG05
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
Tripping characteristics
In >_ 3… 3... < 15 A
1-pole protected
+23 °C
Ambient temp.
500
5
5
200
200
100
100
1
1
50
20
20
10
10
5
5
2
2
1
1
0,5
0,5
Tripping time
Tripping time
50
0,3
0,2
0,1
1,05 1,32
2
3
4
5
8
10
[ x In ]
Multiple of rated current
0,3
0,2
0,1
1,05 1,32
2
3
4
5
8
Multiple of rated current
10
[ x In ]
Effect of ambient temperature 1)
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below.
* Temperature must be measured at the rear of the breaker next
to the terminals after equipment operating temperature has been
reached.
* Ambient temperature [°C] Correction factor
–10
0,89
– 5
0,91
0
0,92
+23
1,00
+30
1,03
+40
1,08
+55
1,16
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at
+ 40 °C ambient temperature
Configuratorcode (example)
Type
Order code TA 45
(2-pole rocker-switch
without accessories)
DF11 - ABTWF150C0 - 000 - 111 - 009
see table 1
1) Example
6,0 A
+40 °C
1,08
6 A x 1,08 = 6,5 A
Optional Variants
0 standard
9 V-Lock
Colour
0 black
Mounting
0 Screw mounting
1 Snap-in mounting s = 1.0 mm
2 Snap-in mounting s = 1.5 mm
3 Snap-in mounting s = 2.0 mm
4 Snap-in mounting s = 2.5 mm
5 Snap-in mounting s = 3.0 mm
Terminal PE
0 without terminal (PCII)
1 Quick-connect terminal 6.3x0.8 mm
Terminal N
1 Quick-connect terminals 6.3x0.8mm, without connection to TA45
3 connection to TA45 non insulated
Terminal L
1 Quick-connect terminals 6.3x0.8mm, without connection to TA45
3 connection to TA45 non insulated
Connectors
5
DF11
Packaging unit
Power entry modules without line filter
https://www.schurter.com /PG05
20 Pcs
Accessories
Description
Assorted Covers
Rear Cover
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
Appliance Outlet further types to DF11
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4782
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4300-06
IEC Connector C15 for hot conditions 120°C, Rewireable, Straight
4781
IEC Connector C15 for hot conditions 120°C, Rewireable, Angled
4784
Connector further types to DF11
...
Mating Outlets/Connectors shuttered
Power Cord Overview complete
VAC13KS, Overview, diverse Connector IEC C13, cord end:
VAC13KS
Power Cord further types to DF11
11.09.2018
6
Connectors
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.