0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DF11.ABDBL150C0.0010.01

DF11.ABDBL150C0.0010.01

  • 厂商:

    SCHURTER

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
DF11.ABDBL150C0.0010.01 数据手册
DF11 Power entry modules without line filter https://www.schurter.com /PG05 IEC Appliance Inlet C14 or C18 with recessed Circuit Breaker TA45 C14 C18 See below: Approvals and Compliances 70° C 70° C Description - Panel mount : Screw-on version from front or rear side, snap-in version from front side - 2 Functions : Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole - Quick connect terminals 6.3 x 0.8 mm Characteristics - All single elements are already wired - Circuit Breaker non-illuminated or illuminated - Suitable for use in equipment according to IEC/UL 60950 Other versions on request - Unwired versions - Other rocker marking - Variant with notch for V-Lock mating Cordsets References Alternative: version with line filter   DF12  Substitute for type   6145  Weblinks pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product, Microsite Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data   Ratings IEC Ratings UL/CSA Dielectric Strength Allowable Operation Temperature IP-Protection Insulation cover Terminal Panel Thickness S Material: Housing 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -10 °C to 55 °C appliance inlet/-outlet Circuit Breakers from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I or II acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 C14 / C18 acc. to IEC 60320-1, UL 60320-1, CSA C22.2 no. 60320-1 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I or II Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In ≥ 3A/240VAC : 300A Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in   Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: DF11 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40011305 UL Approvals UL UL File Number: E96454 Connectors 1 DF11 Power entry modules without line filter https://www.schurter.com /PG05 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to UL 60320-1 Standard for Attachment Plugs and Receptacles Designed according to CSA C22.2 no. 60320-1 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment. Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. MicrositeV-Lock SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification Dimensions [mm] Screw-on mounting 76.7 2.3 28.2 41.7 29 ±0.10 73.5 ±0.10 72.7 73.2 37.1 82.5 10.6 .05 ±0 9.4 9.15 Ø 3.3 0.8 Ø 6.4 2 27.9 Connectors 4.8 55 6 2. R R R R 2.8 7 4. R 2.9 3 /M ø 3.6 4.5 ±0.05 9.7 9.45 5 4.5 91.5 28.7 82.5 ±0.10 32.5 DF11 Power entry modules without line filter https://www.schurter.com /PG05 Snap-in version 76.7 2.3 41.7 28.2 29 ±0.10 73.5 ±0.10 73.2 37.1 77 10.6 72.7 28.7 .05 1.9 S ±0.1 27.9 55 2. 32.5 R R R 2.8 7 4. R 2.15 9.7 9.45 ±0 5 2.9 4.8 * --- Version TA45 with undervoltage release Diagrams L L' P1 1) 2) PE N PE' N' P2 1) Line 2) Load Connectors 3 DF11 Power entry modules without line filter https://www.schurter.com /PG05 Table 1 Selection for type TA45 Order example ABT W • Circuit Breaker of Equipment • 2-pole, rocker actuated • Quick connect terminal Other types on request Diagram Thermal overload protection Without illumination With illumination 1-pole 2-pole P2 P2 P1 4 3 P1 3 6 220…240 V 110…120 V ABT ABD A12 A14 A32 A34 } Colours Switch front W B 6 Rocker black black black white black – – – orange transp. Rocker legend K printed / bedruckt L printed / bedruckt l printed / bedruckt white / weiss Position of the rocker legend e.g F Illustration M printed black P printed I O white printed I O black R Rated current circuit breaker of equipment In Code In Code In Code In Code 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 J01 J02 J03 J04 J05 J06 J07 J08 J09 J10 J11 J12 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,5 J13 J14 J15 J16 J17 J18 J19 J20 J21 J22 J23 J25 2,8 3,0 3,5 4,0 4,5 5,0 6,0 6,5 7,0 7,5 8,0 9,0 J28 030 035 040 045 050 060 065 070 075 080 090 10,0 11,0 12,0 13,0 14,0 15,0 20,0 100 110 120 130 140 150 200 Without release: code C0 Undervoltage release P2 P1 U< 4 P2 Remote trip release b U< P1 Colour of print l white / weiss embossed / Relief H Surface O l O black / schwarz F ON ON Colour of print OFF OFF Illustration O Surface P2 ba P1 P2 c P1 U< U E Z A Code Rated voltage Un • • • • 2 240 V AC • • • • 3 230 V AC • • • • 4 120 V AC Connectors F 150 C0 DF11 Power entry modules without line filter https://www.schurter.com /PG05 Technical data (continued) Circuit breaker Tripping characteristics In < 3 A Tripping characteristics In >_ 3… 3... < 15 A 1-pole protected +23 °C Ambient temp. 500 5 5 200 200 100 100 1 1 50 20 20 10 10 5 5 2 2 1 1 0,5 0,5 Tripping time Tripping time 50 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10 [ x In ] Multiple of rated current 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 Multiple of rated current 10 [ x In ] Effect of ambient temperature 1) The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below. * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. * Ambient temperature [°C] Correction factor –10 0,89 – 5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16 Rated current at +23 °C Ambient temperature Correction factor Chosen rated current at + 40 °C ambient temperature Configuratorcode (example) Type Order code TA 45 (2-pole rocker-switch without accessories) DF11 - ABTWF150C0 - 000 - 111 - 009 see table 1 1) Example 6,0 A +40 °C 1,08 6 A x 1,08 = 6,5 A Optional Variants 0 standard 9 V-Lock Colour 0 black Mounting 0 Screw mounting 1 Snap-in mounting s = 1.0 mm 2 Snap-in mounting s = 1.5 mm 3 Snap-in mounting s = 2.0 mm 4 Snap-in mounting s = 2.5 mm 5 Snap-in mounting s = 3.0 mm Terminal PE 0 without terminal (PCII) 1 Quick-connect terminal 6.3x0.8 mm Terminal N 1 Quick-connect terminals 6.3x0.8mm, without connection to TA45 3 connection to TA45 non insulated Terminal L 1 Quick-connect terminals 6.3x0.8mm, without connection to TA45 3 connection to TA45 non insulated Connectors 5 DF11 Packaging unit   Power entry modules without line filter https://www.schurter.com /PG05 20 Pcs  Accessories Description Assorted Covers Rear Cover   Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to DF11   Connector Overview complete   4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782 4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 IEC Connector C15 for hot conditions 120°C, Rewireable, Straight 4781 IEC Connector C15 for hot conditions 120°C, Rewireable, Angled 4784 Connector further types to DF11 ... Mating Outlets/Connectors shuttered Power Cord Overview complete VAC13KS, Overview, diverse Connector IEC C13, cord end: VAC13KS Power Cord further types to DF11 11.09.2018   6 Connectors The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.
DF11.ABDBL150C0.0010.01 价格&库存

很抱歉,暂时无法提供与“DF11.ABDBL150C0.0010.01”相匹配的价格&库存,您可以联系我们找货

免费人工找货