0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DF12.2078.7310.1

DF12.2078.7310.1

  • 厂商:

    SCHURTER

  • 封装:

    -

  • 描述:

    DF12.2078.7310.1

  • 数据手册
  • 价格&库存
DF12.2078.7310.1 数据手册
DF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 IEC Appliance Inlet C14 with Filter, Circuit Breaker TA45 (recessed) Screw-on from front side Rocker non-illuminated white Screw-on from front side Rocker illuminated orange C14 See below: Approvals and Compliances 70° C Description - Panel mount : Screw-on mounting front side - 3 Functions : Appliance Inlet Protection class I , circuit breaker type TA45 2-pole , Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm Characteristics - All single elements are already wired - Circuit Breaker non-illuminated or illuminated - Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP) For applications according IEC/UL 62368-1 we recommend variants with bleed resistor Other versions on request - Unwired versions - Other rocker marking - Medical Version (M80) - Capacitance CX1 - Variant with notch for V-Lock mating Cordsets References Alternative: version without line filter   DF11  Substitute for type   5145  Alternative: Standard version   Weblinks pdf data sheet, html datasheet, General Product Information, Approvals, Distributor-Stock-Check, Accessories, Detailed request for product Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Panel Thickness S Material   1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz 1 - 15 A @ Ta 40 °C / 250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -10 °C to 55 °C 10/055/21 acc. to IEC 60068-1 front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance inlet/-outlet Circuit Breakers Line Filter MTBF C14 acc. to IEC 60320-1 UL 60320-1, CSA C22.2 no. 60320-1 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In ≥ 3A/240VAC : 300A Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 100'000 h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. EMC Products 1 DF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: DF12 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40012935 UL Approvals UL UR File Number: E72928 Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 60320-1 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Passive filters for suppressing electromagnetic interference Designed according to CSA C22.2 no. 60320-1 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Design Standard Description Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements Suitable for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. UKCA declaration of conformity SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP) Product standards Product standards that are referenced Organization Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification Medical Equipment 2 EMC Products DF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Dimension [mm] Screw-on mounting 76.2 33.5 10.6 41.2 28.7 2.8 29.4 75.5 ±0.10 82.5 ±0.10 74.3 73.2 37.1 92.5 82.5 R 3. 05 36 R Ø 6.4 9.7 47.2 29.8 3. /M 3.5 0.8 Ø ±0.05 3 6 9.65 R6 .5 R 4. 7 5 3 3. Ø 3.3 ±0 R 9.2 R 2.8 10.15 9.7 21.1 .05 75 3. 30.8 ±0.10 5.3 * --- Version TA45 with undervoltage release Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard 2 x 11 100 2.2 1 2 Standard 2x4 100 2.2 1 3 Standard 2 x 2.5 100 2.2 1 4 Standard 2 x 1.6 100 2.2 1 6 Standard 2 x 0.7 100 2.2 1 8 Standard 2 x 0.6 100 2.2 1 10 Standard 2 x 0.4 100 2.2 1 15 Standard 2 x 0.1 100 2.2 1 2 Medical (M5) 2x4 100 - 1 3 Medical (M5) 2 x 2.5 100 - 1 4 Medical (M5) 2 x 1.6 100 - 1 6 Medical (M5) 2 x 0.7 100 - 1 8 Medical (M5) 2 x 0.6 100 - 1 10 Medical (M5) 2 x 0.4 100 - 1 15 Medical (M5) 2 x 0.1 100 - 1 EMC Products 3 DF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Diagrams Medical Version (M5) L’ L P1 PE Cy Cx N L2 Cy TA 45 L1 1) PE’ N’ 2) PE Cx PE’ R L2 N’ N 2) P2 1) Line 2) Load Attenuation Loss - - - - 50Ω differential mode _____ 50Ω common mode Standard version 1A 2A 3A 4A 6A 8A 10 A 15 A 1A 2A 3A 4A 6A 8A 10 A 15 A Medical version (M5) 4 P1 L1 1) P2 1) Line 2) Load L’ L TA 45 Standard version EMC Products DF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Effect of ambient temperature The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: Ambient Temperature [°C] Correction factor -10 0.89 -5 0.91 0 0.92 +23 1.00 +30 1.03 +40 1.08 +55 1.16 Example: With a nominal current of 5A and an ambient temperature of 40°C, a correction factor of 1.08 results. This results in a nominal current of 5.5 A, which is rounded up to the next higher nominal current 6 A. Time-Current-Curves Tripping Characteristics In ≥ 3 ... ≤ 15 A Tripping Characteristics In < 3 A [ min ] [ sec ] 10’000 [ min ] [ sec ] 10’000 Type TA45 Rated current In < 3 A 60 2000 30 20 1000 10 Ambient temp. Type TA45 I n > 3... < 15 A Rated current 1-pole pr otected 60 2- pole protected 30 1-pole p rotected 2’000 20 +23 °C 10 500 2- pole protected 1’000 +23 °C Ambient temp. 500 5 5 200 200 100 1 100 1 50 20 20 10 10 5 5 2 2 1 1 0,5 0,5 Tripping time Tripping time 50 0,3 0,2 0,1 1,05 1,32 2 Multiple of rated curr ent 3 4 5 8 10 [ x In ] 0,3 0,2 0,1 1,05 1,32 2 3 4 Multiple of rated cur rent EMC Products 5 8 10 [ x In ] 5 DF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Order number key Configuration code TA45 Type • Circuit Breaker of Equipment • 2-pole, rocker actuated • Quick connect terminal Other types on request Configuration code TA45 D F12- A B T WF 15 0C 0 - 0 0 0 - 1111 - 0 0 - 2 1 Without release: code C0 Undervoltage release P2 P2 P1 Remote trip release P1 b U< U< P2 ba P2 P1 c P1 U< Rated voltage Un U E Z A Code • • • • 2 240 V AC • • • • 3 230 V AC • • • • 4 120 V AC Rated current circuit breaker of equipment In Code 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 J01 J02 J03 J04 J05 J06 J07 J08 J09 J10 J11 J12 In 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,5 Code In Code In Code J13 J14 J15 J16 J17 J18 J19 J20 J21 J22 J23 J25 2,8 3,0 3,5 4,0 4,5 5,0 6,0 6,5 7,0 7,5 8,0 9,0 J28 030 035 040 045 050 060 065 070 075 080 090 10,0 11,0 12,0 13,0 14,0 15,0 20,0 100 110 120 130 140 150 200 Rocker legend Surface white M printed black P printed I O white R printed I O black printed printed ON ON K L l O OFF OFF O printed Colour of print O H Illustration l embossed l F Position of the rocker legend e.g F white black Colours Switch front W B 6 black black black Rocker white black – – – orange transp. Diagram Thermal overload protection 1-pole 2-pole P2 P2 P1 4 3 6 Without illumination With illumination 6 EMC Products 220…240 V 110…120 V P1 3 ABT ABD A12 A14 A32 A34 DF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Configuration code TA45 Type • Circuit Breaker of Equipment • 2-pole, rocker actuated • Quick connect terminal Other types on request Configuration code TA45 D F 12-A B T WF 15 0C0 - 0 0 0 - 1111 - 0 0 - 2 1 Without release: code C0 Undervoltage release P2 P2 P1 Remote trip release P1 b U< U< P2 ba P2 P1 c P1 U< Rated voltage Un U E Z A Code • • • • 2 240 V AC • • • • 3 230 V AC • • • • 4 120 V AC Rated current circuit breaker of equipment In Code In Code In Code In Code 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 J01 J02 J03 J04 J05 J06 J07 J08 J09 J10 J11 J12 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,5 J13 J14 J15 J16 J17 J18 J19 J20 J21 J22 J23 J25 2,8 3,0 3,5 4,0 4,5 5,0 6,0 6,5 7,0 7,5 8,0 9,0 J28 030 035 040 045 050 060 065 070 075 080 090 10,0 11,0 12,0 13,0 14,0 15,0 20,0 100 110 120 130 140 150 200 Rocker legend Surface printed Colour of print printed printed white M printed black P printed I O white R printed I O black l ON ON l K L O OFF OFF O H Illustration O embossed l F Position of the rocker legend e.g F white black Colours Switch front W B 6 black black black Rocker white black – – – orange transp. Diagram Thermal overload protection 1-pole 2-pole P2 P2 P1 4 3 6 Without illumination With illumination 220…240 V 110…120 V EMC Products P1 3 ABT ABD A12 A14 A32 A34 7 DF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Configuration code (Order example) Type Configuration code TA45 DF11- ABTWF150C0 - 000 - 1111 - 00 - 21 Optional Variants 00 Standard 21 V-Lock notch Colour 0 Black Mounting 0 Screw mounting Terminal PE 1 QC 6.3x0.8 Terminal L and N 1 QC 6.3x0.8, without connection to TA45 3 Connection to TA45 non insulated Type of mains filter / capacitor / bleed resistor 1 Standard X2, Y2 with bleed resistor 3 Medical M5 X2 with bleed resistor Rated current 11A 22A 33A 44A 56A 68A 7 10 A 9 15 A The rated current of the mains filter must not be less than the tripping current of the circuit breaker for equipment. Only the rated filter current is shown in the item description on the packaging. 8 EMC Products DF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Configuration code (Order example) Type Configuration code TA45 DF11- ABTWF150C0 - 000 - 1111 - 00 - 21 Optional Variants 00 Standard 21 V-Lock notch Colour 0 Black Mounting 0 Screw mounting Terminal PE 1 QC 6.3x0.8 Terminal L and N 1 QC 6.3x0.8, without connection to TA45 3 Connection to TA45 non insulated Type of mains filter / capacitor / bleed resistor 1 Standard X2, Y2 with bleed resistor 3 Medical M5 X2 with bleed resistor Rated current 11A 22A 33A 44A 56A 68A 7 10 A 9 15 A The rated current of the mains filter must not be less than the tripping current of the circuit breaker for equipment. Only the rated filter current is shown in the item description on the packaging. Variants Circuit Breakers Filter Connectors Rated Current [A] Rocker colour Illumination Add-on modules Rated Current [A] Filter Type Protection Class 1 black non-illuminated without 1 Standard 10 white non-illuminated without 10 15 white non-illuminated without 15 black non-illuminated without V-Lock Internally wired Config. Code Order Number I prewired DF12-ABDBLJ10C0-000-1131-00-00 DF12.1310.1110.1 Standard I prewired DF12-ABDWF100C0-000-7131-00-00 DF12.0470.7110.1 15 Standard I prewired DF12-ABDWF150C0-000-9131-00-00 DF12.0885.9110.1 15 Standard I prewired DF12-ABDBL150C0-000-9131-00-00 DF12.1089.9110.1 EMC Products 9 DF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Circuit Breakers Filter Connectors Rated Current [A] Rocker colour Illumination Add-on modules Rated Current [A] Filter Type Protection Class 15 orange illuminated without 15 Standard 2 orange illuminated without 2 3 orange illuminated without 4 orange illuminated 5 black 8 V-Lock Internally wired Config. Code Order Number I prewired DF12A326F150C0-000-9131-00-00 DF12.2851.9110.1 Standard I prewired DF12A326KJ20C0-000-2131-00-00 DF12.3803.2110.1 3 Standard I prewired DF12A326K030C0-000-3131-00-00 DF12.3635.3110.1 without 4 Standard I prewired DF12A346K040C0-000-4131-00-00 DF12.3945.4110.1 non-illuminated without 6 Standard I prewired DF12-ABTWF050C0-000-5131-00-00 DF12.0586.5110.1 white non-illuminated without 8 Standard I prewired DF12-ABTWF080C0-000-6131-00-00 DF12.0423.6110.1 10 white non-illuminated without 10 Medical (M5) I prewired DF12-ABDWF100C0-000-7331-00-00 DF12.0470.7310.1 10 black non-illuminated without 10 Medical (M5) I prewired DF12-ABDBL100C0-000-7331-00-00 DF12.2078.7310.1 12 black non-illuminated without 15 Medical (M5) I prewired DF12-ABDBL120C0-000-9331-00-00 DF12.2420.9310.1 15 white non-illuminated without 15 Medical (M5) I prewired DF12-ABTWF150C0-000-9331-00-00 DF12.0031.9310.1 15 black non-illuminated Remote trip release 15 Medical (M5) I prewired DF12-ABDBH150A3-000-9331-00-00 DF12.4051.9310.1 2 black non-illuminated without 2 Medical (M5) I prewired DF12-ABDWRJ20C0-000-2331-00-00 DF12.3171.2310.1 3 black non-illuminated without 3 Medical (M5) I prewired DF12-ABDBL030C0-000-3331-00-21 DF12.2370.3310.121 4 orange illuminated without 4 Medical (M5) I prewired DF12A326H040C0-000-4331-00-00 DF12.0723.4310.1 6 black non-illuminated without 6 Medical (M5) I prewired DF12-ABDBP060C0-000-5331-00-21 DF12.1488.5310.121 7 orange illuminated without 8 Medical (M5) I prewired DF12A346R070C0-000-6331-00-00 DF12.3737.6310.1 l l Availability for all products can be searched real-time: https://www.schurter.com/en/info-center/support-tools/stock-check-distributors Packaging unit  20 Pcs  Accessories Description Assorted_Covers Rear Cover   0859.0109   RC320 Rear Cover for Power Entry Module   10 EMC Products DF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete 4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I 4787 4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder / Quick Connect, 10 A, Suitable for appliances with protection class I 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091   Connector Overview complete 4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782 4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4781 Mounting: Power Cord, Cable, Connector: IEC C15 4781 4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15 4784   Mating Outlets/Connectors shuttered Connector Overview complete 4783 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4783   Power Cord Overview complete VAC13KS, Overview, V-Lock cord retaining, diverse Connector IEC C13, diverse, black VAC13KS 28.03.2024   The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. EMC Products 11
DF12.2078.7310.1 价格&库存

很抱歉,暂时无法提供与“DF12.2078.7310.1”相匹配的价格&库存,您可以联系我们找货

免费人工找货