GRM2.1161.023 数据手册
Power Entry Modules with Line Filter www.schurter.com/pg06 IEC Appliance Inlet C14 with Line Switch, Fuseholder 1- or 2-pole, Voltage Selector (series-parallel), "Lock and Shield" Mounting, GRM2 GRM2: only with shield, without line filter C14 70° C Description - Panel Mount: Snap-in version from rear-side - 5 Functions: Appliance Inlet Protection class I, Line Switch 2-pole, with or without Fuseholder for fuse-links 5 x 20 mm, with or without voltage selector, with EMC-shield Characteristics Approvals - VDE License Number: 40024784 - UL License Number: E93617 - Ultra-compact design Time saving "Lock and Shield" snap-in design for rear-panel mounting - All single elements are already wired - Fuseholder on the inside of the equipment prevents accidental use of incorrect fuse-links by the user - Voltage selector for two voltage ranges Innovative EMC-shielding with flexible steel segments for an excellent contact to the panel - Insulation cover on the rear-side - Qualified for use in equipment according IEC/EN 60950 Other versions on request - Panel thickness 1.0 / 2 / 2.5 mm (max.) - Fuseholder 1-pole - Line switch 1-pole - Voltage selector with other marking References Weblinks General Product Information Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store, Distributor-Stock-Check, Accessories Technical Data Ratings IEC Ratings UL/CSA Dielectric Strength 10 A @ Ta 40 °C / 250 VAC; 50 Hz 10 A @ Ta 40 °C / 125 VAC; 60 Hz > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 °C to 85 °C 25/085/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class 1 acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Solder terminal on request Solder terminals for voltage selector Snap-in: 1.5 mm (other on request) Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class 1 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm 5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole Admissible power acceptance at higher ambient temperature see derating curves Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details optional, jumper, 2 pos. > 1'400'000 h acc. to MIL-HB-217 F Fuseholder Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal Rated Power Acceptance @ Ta 23 °C Power Acceptance @ Ta > 23°C Line Switch Panel Thickness s Material: Housing Voltage Selectors MTBF EMC Products  GRM2 www.schurter.com/pg06 Dimensions GRM2 48.3 mm Power Entry Modules with Line Filter 49.5 33.9 26.0 13.4 L +0.1 0 4.5 42.3 38.4 45.4 3.9 12.5 8.4 13.45 ±0.1 PE N 1.7 R5 5 4.5 24 2.2 31.7 S 0.05 min.8 *) E 8.6 PE 6.5 2 6.9 ±0.1 34.2 ±0.05 Dimensions Step 1 Step 2 Step 3 Place the socket in top edge of the panel cut-out. Push the socket upwards. Push the socket forward into the panel cut-out. Step 4 Release the socket. The component is self adjusting. Diagrams Voltage selector GRM2 1) Line 2) Load 2 EMC Products 40.9 R1 Power Entry Modules with Line Filter www.schurter.com/pg06 GRM2 Derating Curves 1-pole 2.0 2-pole Admissible power acceptance in Watt per pole 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 0 20 40 60 80 100 I = 1.0 In I = 0.7 In I = < < In Admissible power acceptance in Watt 1.5 I = 1.0 In 1.0 I = 0.7 In I = < < In 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta °C Ambient air temperature Ta °C Variants Basic version: - Marking of the voltage selector 115/230 - with housing and cover on the rear-side Rated Current [A] 10 10 10 10 Filter-Type without without without without Fuseholder 2-pole 2-pole Line Switch 2-pole 2-pole 2-pole 2-pole l l Voltage Selectors Order Number GRM2.1160.013 GRM2.1161.023 GRM2.1180.013 GRM2.1181.023 Packaging unit 20 Pcs Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal Appliance Outlet further types to GRM2 Connector Overview complete IEC Connector C15, Rewireable, Straight IEC Connector C15A, Rewireable, Straight IEC Connector C15A, Rewireable, Straight IEC Connector C15A, Rewireable, Angled IEC Connector C13, Rewireable, Angled Connector further types to GRM2 Power Cord Overview complete Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13 Power Cord further types to GRM2 0311 3011 3012 3013 3020 ... 0101 0102 0102-G 0112 4012 ... 4787 4788 5091 5092 The specifications, descriptions and illustrations indicated in this document are based on EMC Products current information. All content is subject to modifications and amendments. 
GRM2.1161.023
1. 物料型号: - 型号:GRM2 - 描述:带有线路滤波器的电源输入模块,具有线路开关、保险座、电压选择器(串联-并联)、“锁定和屏蔽”安装方式。

2. 器件简介: - 该器件为面板安装式,提供5种功能:I类电器入口保护、2极线路开关、带或不带5x20mm熔断器的保险座、带或不带电压选择器、带EMC屏蔽选择器和EMC屏蔽。 - 认证:VDE许可证号40024784,UL许可证号E93617。

3. 引脚分配: - 快速连接端子:4.8 x 0.8 mm,可根据要求提供焊接端子和电压选择器的焊接端子。

4. 参数特性: - 额定电流:IEC 10A@Ta40°C/250VAC;50Hz,UL/CSA 10A@Ta 40°C/125VAC;60Hz。 - 耐压:L-N间>1.7kVDC,L/N-PE间>2.7kVDC(测试电压2秒)。 - 工作温度:-25°C至85°C。 - 防护等级:前侧IP40,符合IEC 60529。 - 保护等级:适用于保护等级为1的电器,符合IEC 61140。

5. 功能详解: - 超紧凑型设计,节省时间的“锁定和屏蔽”快装设计,适用于后面板安装。 - 所有单一元素已预先连接。 - 设备内部的保险座防止用户意外使用错误的保险丝。 - 电压选择器用于两个电压范围。 - 创新的EMC屏蔽,具有灵活的钢制段,与面板接触良好。 - 设备后侧有绝缘盖。 - 适用于IEC/EN 60950标准的设备。

6. 应用信息: - 适用于需要电源输入和EMC屏蔽的电器设备。

7. 封装信息: - 材料:黑色热塑性塑料,UL 94V-0。 - 面板厚度:快装式1.5mm(其他尺寸可定制)。