GRM4.5522.013

GRM4.5522.013

  • 厂商:

    SCHURTER

  • 封装:

    -

  • 描述:

    PWR ENT MOD RCPT IEC320-C14 PNL

  • 详情介绍
  • 数据手册
  • 价格&库存
GRM4.5522.013 数据手册
Power entry modules with line filter www.schurter.com/pg06 "Lock and shield" mounting, line switch, fuseh. 5x20 mm with/without voltage sel. (series-parallel) GRM4 Standard- or Medical-Filter Snap-In Version GRM4: with shield and line filter C14 70° C Description - Panel Mount: Snap-In Version from rear-side - 5 Functions: Inlet Protection class I, Line switch 2-pole, with or without Fuseholder for fuse-links 5 x 20 mm, with or without voltage selector, Line filter in standard and medical version - On phase-out, not recommended for new design Approvals - VDE License Number: 118913 - UL License Number: E72928 - CSA License Number: 701867 Technical Data Ratings IEC Ratings UL/CSA Leakage Current AS 0.5 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz 0.5 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 °C to 85 °C 25/085/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Solder terminal on request Solder terminals for voltage selector Snap-in: 1.5 mm (other on request) Thermoplastic, black, UL 94V-0 EReferences Weblinks General Product Information Appliance-Inlet /-Outlet Fuseholder Rated Power Acceptance @ Ta 23 °C Power Acceptance @ Ta > 23°C Line Switch Voltage selector Line Filter MTBF Dielectric Strength Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal PH Panel Thickness s Material: Housing EMC products OU Characteristics Other versions on request - Panel thickness 1.0 / 2 / 2.5 mm (max.) - Fuseholder 1-pole - Line switch 1-pole - Voltage selector with other marking - Ultra-compact design Time saving "Lock and Shield" snap-in design for rear-panel mounting - All single elements are already wired - Fuseholder on the inside of the equipment prevents accidental use of incorrect fuse-links by the user - Voltage selector for two voltage ranges Innovative EMC-shielding with flexible steel segments for an excellent contact to the panel - Insulation cover on the rear-side - Qualified for use in equipment according IEC/EN 60950 Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check, Distributor-Stock-Check T C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 °C, 10 A, Protection class I 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm 5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole Admissible power acceptance at higher ambient temperature see derating curves Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details optional, jumper, 2 digits Standard and Medical Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details > 1'400'000 h acc. to MIL-HB-217 F  GRM4 www.schurter.com/pg06 Dimensions GRM4 49.5 33.9 Power entry modules with line filter Length 48.3 mm 26.0 13.4 L 12.5 6.5 8.4 PE N 1.7 R5 4.5 2.2 31.7 S 0.05 min.8 *) E 5 24 45.2 E = 31.7 mm with fuseholder E = 26.25 mm without fuseholder *) Min. space to remove the fuseholder cover Technical Data of Filter-Components Rated Current [A] 0.5 1 3 6 10 0.5 1 3 6 10 Filter-Type Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances L [mH] 2 x 24 2 x 12 Capacitance CX [nF] 100 100 100 100 100 100 100 100 100 100 Capacitance CY [nF] 2.2 2.2 2.2 2.2 2.2 - 2 x 0.78 2 x 0.225 2 x 24 2 x 12 2 x 0.78 2 x 0.225 Dimensions Step 1 Place the socket in top edge of the panel cut-out. PH Release the socket. The component is self adjusting.  Step 4 AS Step 2 Push the socket upwards. E2 x 2.5 1 1 1 1 1 2 x 2.5 EMC products OU 7 ±0.1 6.9 ±0.1 8.6 2 R [MΩ] - Step 3 Push the socket forward into the panel cut-out. T PE 34.2 ±0.05 40.9 4.5 +0.1 0 42.3 38.4 30.4 45.4 3.9 R1 Power entry modules with line filter www.schurter.com/pg06 GRM4 GRM4 Medical version Diagrams Voltage selector GRM4 Standard version 1) Line 2) Load 1) Line 2) Load 2-pole Admissible power acceptance in Watt per Pole 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 0 20 40 60 80 I = 1.0 In I = 0.7 In I = < < In 2.0 1.5 I = 1.0 In 1.0 I = 0.7 In I = < < In 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta °C Ambient air temperature Ta °C Attenuation Loss 0.5 A Standard version 1A 10 A Medical version (M5) 0.5 A AS 1A E3A 6A PH 10 A EMC products OU 100 Derating Curves 1-pole Admissible power acceptance in Watt 3A T - - - - differential mode _____ common mode 6A  GRM4 www.schurter.com/pg06 Variants Basic version: - Marking of the voltage selector 115/230 - with housing and cover on the rear-side Rated Current [A] 6 0.5 0.5 1 1 3 3 6 6 10 10 0.5 0.5 1 1 3 3 6 6 10 10 0.5 0.5 1 1 3 3 6 6 10 10 0.5 0.5 1 1 3 3 6 6 10 10 Filter-Type Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Fuseholder 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole Line Switch 1 pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Power entry modules with line filter Distributor-Stock-Check | SCHURTER-Stock-Check | e-Store Voltage selector l Order Number GRM4.4401.013 GRM4.4102.013 GRM4.4102.123 GRM4.4202.013 GRM4.4202.123 GRM4.4302.013 GRM4.4302.123 GRM4.4402.013 GRM4.4402.123 GRM4.4502.013 GRM4.4502.123 GRM4.4122.013 GRM4.4122.123 GRM4.4222.013 GRM4.4222.123 GRM4.4322.013 GRM4.4322.123 GRM4.4422.013 GRM4.4422.123 GRM4.4522.013 GRM4.4522.123 GRM4.5102.013 GRM4.5102.123 GRM4.5202.013 GRM4.5202.123 GRM4.5302.013 GRM4.5302.123 GRM4.5402.013 GRM4.5402.123 GRM4.5502.013 GRM4.5502.123 GRM4.5122.013 GRM4.5122.123 GRM4.5222.013 GRM4.5222.123 GRM4.5322.013 GRM4.5322.123 GRM4.5422.013 GRM4.5422.123 GRM4.5522.013 GRM4.5522.123 PH Packaging unit 120 Pcs 4 AS 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole 2-pole E- The specifications, descriptions and illustrations indicated in this document are based on EMC products current information. All content is subject to modifications anamendments. OU T
GRM4.5522.013
1. 物料型号: - 型号为GRM4,是一种带有屏蔽和线路滤波器的电源输入模块。

2. 器件简介: - 该器件支持从后侧的快装版本,具有5种功能:入口保护I类、2极线路开关、带或不带5x20mm熔断器座、带或不带电压选择器、标准和医疗版本的线路滤波器。该产品已逐渐淘汰,不建议用于新设计。

3. 引脚分配: - 快速连接端子尺寸为4.8 x 0.8 mm,可根据要求提供焊接端子和电压选择器的焊接端子。

4. 参数特性: - 额定电流:IEC标准下0.5-10A@Ta40°C/250VAC;50Hz,UL/CSA标准下0.5-10A@Ta40°C/125VAC;60Hz。 - 漏电流:标准版<0.5mA(250V/60Hz),医疗版<5μA(250V/60Hz)。 - 耐压:L-N间>1.7kVDC,L/N-PE间>2.7kVDC,测试电压(2秒)。 - 工作温度:-25°C至85°C。 - 防护等级:前侧IP40,符合IEC60529标准。 - 保护等级:适用于IEC61140标准的I类电器。

5. 功能详解: - 超紧凑型设计,节省时间的“锁定和屏蔽”快装设计,用于后面板安装。 - 设备内部的熔断器座防止用户意外使用错误的熔断器。 - 电压选择器用于两个电压范围。 - 创新的EMC屏蔽,具有灵活的钢制段,与面板接触良好。 - 设备后侧有绝缘盖。 - 适用于IEC/EN 60950标准的设备。

6. 应用信息: - 适用于IEC/EN 60950标准的设备,提供多种版本,包括不同厚度的面板、1极熔断器座、1极线路开关、不同标记的电压选择器等。

7. 封装信息: - 外壳材料为黑色热塑性塑料,符合UL 94V-0标准。 - 快装式面板厚度为1.5mm(其他尺寸可定制)。
GRM4.5522.013 价格&库存

很抱歉,暂时无法提供与“GRM4.5522.013”相匹配的价格&库存,您可以联系我们找货